6ES5 928-3UA12

Siemens 6ES5 928-3UA12 — CPU 928A processor module for S5-135U / S5-155U

Siemens 6ES5 928-3UA12 is a CPU 928A processor module for S5-135U / S5-155U central controllers. Within the Siemens S5 family, this SIMATIC S5 CPU executes the user program and handles the machine’s logic, calculations and data processing. Its programming language is STEP 5.

For this order number, pay particular attention to the plug-in user memory and two-slot construction. Check memory and mounting arrangements before selecting a different suffix as a replacement.

User memory versus DB-RAM

A RAM or EPROM submodule is required to store the program; external user-memory capacity is up to 64 KB. The approximately 46 KB internal DB-RAM is for data blocks. It is not built-in program storage. When examining S5 memory submodules, record the complete number and capacity of the memory supplied with the CPU.

A photograph of the processor alone does not establish that user memory is included in a used-equipment sale. Check the program backup, memory submodule and processor as separate items before planning the work.

Differences from 3UA11, 3UA21 and CPU 928B

Program-execution limits differ from 6ES5 928-3UA11: 3UA12 permits a block nesting depth of 62, compared with 30 for 3UA11. The maximum permitted cycle time is 6000 ms for 3UA12 and 4000 ms for 3UA11. This is the cycle-monitoring limit, not a claim that each scan takes six seconds.

Siemens identifies 6ES5 928-3UA21 as a partially compatible successor. 6ES5 928-3UB11 and 6ES5 928-3UB12 are different CPU 928B models. Compare the program, memory arrangement, connections and rack layout before deciding on a replacement.

Rack mounting and power

The processor occupies two slots and receives 5 V through the backplane, with a typical current consumption of 3.5 A. Assess the S5 rack layout and S5 power-supply load against the installed module list. These ratings are not instructions to apply 24 V directly to the processor.

Switch off the system supply before inserting or removing the module. The basic and expansion boards form one unit and must not be separated. Check the rear connectors and guides, and use the position marked for the CPU in the rack.

PG connection and STEP 5 project

The front panel has a 15-pin PG interface; the serial PG transmission rate is 9600 bit/s. Select the correct S5 programming cable for the interface. If communication fails, compare the cable, converter and PG settings with a known-good arrangement before condemning the processor.

For PLC programming work, preserve the STEP 5 blocks, symbols and current data values together. A ladder representation helps maintenance, but verify that the comments and symbols belong to the same version as the blocks read from the CPU. Include settings for the installed communication modules in the replacement record.

Multiprocessor configuration and addressing

CPU 928 supports single-processor operation or up to four CPUs in a suitable central controller. For a multiprocessor installation, examine the COR 923C coordinator and allocation of tasks between processors. Add the connections of the S5 interface modules to the rack drawing.

Do not infer digital input and digital output addresses solely from physical module positions. Compare the addresses of analog modules and combined I/O modules with the project and hardware records. Where a DB 1 address list is used, check it alongside the relevant CPU’s task allocation.

Reset and diagnostics

OVERALL RESET clears and initializes the RAM areas on the CPU and any fitted RAM submodule. Back up the program, DB/DX values and accessible diagnostic information first. For PLC debugging, retain ISTACK/BSTACK records together with LED states to help investigate the stop.

Reaching RUN does not establish that the complete machine application has been verified. Record PG communication, program reading, memory checks and application testing separately.

Editor’s note

When buying used, start with the memory receptacle. In S5 maintenance, a working processor and a complete, programmed machine spare describe different conditions. Establish exactly which parts are included in the sale.

Ask for a clear label photograph showing 3UA12. A similar front panel does not make 3UA11, 3UA21 or a 3UB version the same product. Keep a photograph of the original processor and its rack position.

The approximately 46 KB DB-RAM does not remove the need for program memory. Check the RAM or EPROM number, contents and readability separately. Missing project data and defective hardware need separate investigation.

Do not separate the two processor boards for cleaning. Photograph bent connectors, corrosion or signs of previous repair. If the module does not seat correctly, investigate the obstruction instead of forcing it into place.

A STOP indication on an operating machine is not a reason to begin with an overall reset. Preserve the backup and stop information, and establish the condition of connected outputs first. Lost production parameters can be difficult to reconstruct.

Record the rack, power supply, memory and PG cable used for a bench test. Ask which checks were completed rather than relying on a RUN-light photograph. State clearly when the application has not been tested; a useful spare needs a meaningful test record.

OtomasyonAVM resources and documentation

+ 6ES5 928-3UA12 model page · Second-hand Siemens S5 models · About Siemens S5 PLCs.

The CPU 928 hardware and programming PDFs are linked in the Siemens references below.

Related models

+ 6ES5 928-3UA11 · 6ES5 928-3UA21 · 6ES5 928-3UB11 · 6ES5 928-3UB12. These are comparison candidates; suitability for direct replacement requires separate verification.

Browse SIMATIC S5

SIMATIC S5 CPUs · S5 memory submodules · S5 cables · S5 racks · Second-hand Siemens products

Siemens and external references

+ Siemens S5-135U/155U System Manual — C79000-G8576-C199-07, English. Section 5.6: CPU 928 hardware, memory and startup; Chapter 6: multiprocessor operation.

+ Siemens CPU 928 Programming Guide — 6ES5 998-1PR21, English. Section 1.1: 3UA12 version differences; program structure, data areas and diagnostics.

+ Siemens 6ES5 928-3UA12 product record. Order number, CPU 928 identification and partially compatible successor.