Delta DVP24ES200R
Delta DVP24ES200R | DVP-ES2 PLC with 16 Digital Inputs and 8 Relay Outputs
The Delta DVP24ES200R is a DVP-ES2 PLC CPU with a 100–240 V AC supply, 16 digital inputs rated at 24 V DC, 8 relay outputs, and 16K steps of program memory. It reads sensors and controls contactors, valves, or indicators in conveyor, packaging, and pump panels.
Inputs, relay outputs, and terminal layout
X0–X7 and X10–X17 are the digital inputs. Wire the S/S common to suit the PNP or NPN output of the inductive sensor or photoelectric sensor. See the guides to sinking and sourcing inputs and analog and digital inputs when checking field signals.
C0 is the common for Y0–Y3, and C1 serves Y4–Y7. Delta rates resistive loads at 2 A per output and 5 A per common. The load type affects relay contact life. Check inrush current and select suitable suppression when switching a contactor or valve coil. For applications requiring high-speed pulse outputs, consider the transistor-output DVP24ES200T.
Which software and cable do you need?
Use WPLSoft or ISPSoft. To connect a computer to COM1 (RS-232), use Delta’s UC-PRG020-12A USB-to-RS-232 cable. A computer with a native RS-232 port can use the UC-MS020-01A cable. Install the USB cable driver and select the assigned COM port in WPLSoft or in COMMGR for ISPSoft. The guides to PLC programming, ladder diagrams, and PLC cables cover initial setup.
COM2 and COM3 are RS-485 ports. When connecting an HMI panel or drive, match the baud rate, parity, and stop bits on the RS-485 bus. Set Modbus RTU or Modbus ASCII to suit the connected devices. For an analog signal such as a 4–20 mA transmitter, select a compatible analog input module.
Editor's Note
Start with the label. When buying a used unit, confirm the full DVP24ES200R model code and check that the removable terminal blocks are present.
Identify the supply terminals. Mains power goes to L and N. The +24V and 24G terminals on the output row provide the 500 mA auxiliary supply.
Test both output banks. Use a low-power test load to check all eight outputs individually through C0 and C1. If the LED lights and the load stays off, check power at the common terminal and then test the contact.
Back up the CPU before removing it. Save the project and the COM2 and COM3 settings so you can reconnect the HMI after replacement.
Check cable routing. Keep the serial bus away from drive output cables. Check for electromagnetic interference and inspect panel grounding when troubleshooting intermittent communication.