Delta DVP10PM00M
Delta DVP10PM00M – Motion Controller with 1 MHz Differential Outputs
Delta DVP10PM00M is a DVP-PM motion controller offering four differential pulse axes up to 1 MHz. With 64K-step program memory and 10K words of data registers, it combines PLC sequencing with fast positioning. The manufacturer specifies 24 onboard I/O points.
These are not identical general-purpose digital points: counter/MPG inputs, differential pulse outputs and open-collector outputs have different electrical roles. For feeding, cut-to-length, mark capture and multi-axis automation, select terminal functions together with the motion mode.
AC power and auxiliary 24 V output
Main supply: 100–240 V AC, 50/60 Hz. The instruction sheet specifies −15%/+10% tolerance, 60 VA consumption and a 2 A/250 V AC fuse. Connect supply to L and N. The +24 V / 24G terminals provide a 500 mA auxiliary output; they are not the main supply input and must not be paralleled with an external power supply.
If sensors and other field circuits use this output, calculate their total current. Provide suitable fusing, protection and grounding. Distinguish AC supply terminals from low-voltage signals when measuring voltage.
Inputs, high-speed counters and MPG
X0–X7 are 24 V DC inputs with a shared common. Select S/S wiring for the NPN/PNP sensor arrangement. Check signal levels and common reference when connecting a sensor, inductive detector, photoelectric sensor or limit switch.
X10±, X11±, X12± and X13± are differential inputs, rated 5–24 V DC and in the 200 kHz class in the instruction sheet. X10/X11 serve MPG pulse inputs; X12/X13 serve differential counting. Match A+/A− and B+/B− correctly when connecting an encoder with line-driver outputs.
The manufacturer specifies six high-speed counter groups: four open-collector and two differential groups. U/D, pulse/direction, A/B and 4A/B evaluation use different counting arrangements and speed calculations. In four-axis configuration, X0/X2/X4/X6 can serve DOG homing signals and X1/X3/X5/X7 PG signals; follow the selected axis mode.
Four differential axes and PWM outputs
Y10/Y11, Y12/Y13, Y14/Y15 and Y16/Y17 form the four differential-axis output pairs. Every signal has +/− terminals. Match U/D, pulse/direction or A/B format to the receiver when using these 1 MHz, 5 V line-driver outputs. Do not wire a differential output as a 24 V open-collector output.
Y0–Y3 provide open-collector outputs with 200 kHz PWM capability. In the documented six-axis configuration, these four terminals can be assigned to two additional pulse axes; their electrical interface differs from the four 1 MHz differential axes. Recheck terminal functions and available general outputs after changing axis mode.
When choosing a servo drive or stepper drive, verify input format, pulse frequency and signal voltage. Calculate electronic gearing together with screw pitch or transmission ratio for the servo motor's mechanical travel. Differential pulse terminals are not relay/coil-driving outputs.
PMSoft, COMMGR and programming cable
PMSoft is the programming tool. Select the exact DVP10PM00M target in PMSoft. Develop the PLC application, Ladder logic, motion parameters and register functions against the model-specific instruction table. Do not assume that a general DVP project transfers directly to this motion controller.
COM1 is RS-232 with an 8-pin mini-DIN connector. A USB computer can use UC-PRG020-12A; a physical RS-232 port can use a correctly wired serial cable such as UC-MS020-01A. That serial cable can also work with a suitable USB-to-RS-232 converter. The CPU has no native USB programming port.
Check the converter's Windows driver and COM number. Create and start the serial channel in COMMGR; in PMSoft Communication Setting, select the same driver, station and Motion Controller connection. Read the model/firmware information first and confirm transfer direction before proceeding.
Motion functions and model differences
JOG, homing, MPG, single-/two-speed positioning, high-speed capture and comparison are core functions of this model. For multi-axis operation, check the selected mode's instructions and shared terminal assignments.
Not every PMSoft menu feature is available on DVP10PM. The manufacturer's 2011 model comparison marks G-code and cyclic/acyclic E-CAM as unsupported for DVP10PM. Do not automatically transfer DVP20PM00D/00M G-code, motion-subroutine and electronic-cam descriptions to this model.
Communication, expansion and battery
The CPU provides COM1 RS-232 and COM2 RS-485. Match station, serial format and Modbus ASCII/RTU settings on RS-232/RS-485 connections. The optional DVP-FPMC card adds Ethernet/CANopen functions in a supported configuration.
The manufacturer specifies up to 256 I/O points; verify extension-module compatibility and power requirements. This model has a battery and BAT.LOW indicator. Battery backup supports retained SRAM areas. The instruction sheet describes PMSoft Options → PLC<=>Flash for permanent Flash saving; back up existing data first.
Related controllers
DVP20PM00D: A PM option with two differential axes up to 500 kHz; assess its motion-command structure and terminals separately.
DVP20PM00M: Three differential axes up to 500 kHz, differing from DVP10PM's four 1 MHz output arrangement.
DVP20PM00DT: A separate PM hardware option. Preserve the DT suffix when matching projects and terminals.
DVP28SV11T2: An SV2 CPU for general PLC and pulse applications. Its NPN output interface and 200 kHz class differ from DVP10PM's 1 MHz differential axes.
Editor's Note
Check the AC supply label first. Do not mistake the auxiliary +24 V output for a supply input. Compare terminal names with the machine drawing when inspecting a removed controller.
Record the PMSoft target and firmware before uploading from a working machine. Preserve axis parameters, homing offsets, electronic gearing, HMI files and drive settings too.
Make the first movement at low speed over a short distance. Compare commanded pulses with actual travel; do not correct direction faults by changing wires at random.
If BAT.LOW illuminates, assess the battery and retained data together. Flash saving and a PC project backup are different operations; restoring old Flash data can change machine settings.
Perform short-circuit and board checks with power isolated. Test each axis separately; provide the required safety relay and independent emergency-stop arrangement instead of relying solely on standard PLC logic.
For a used-unit sale, state quantity, label photographs, working/faulty condition and axis tests. Sales require an invoice; no returns; workshop testing is available. Sellers can send details to otomasyonavm@gmail.com.
PDF documents and related topics
For wiring and programming documents, visit our Delta DVP PLC files page first. The PMSoft user manual explains the software interface; the DVP10PM instruction sheet explains this controller's supply and terminals. Check document edition together with the complete model.
Related topics and navigation: Delta and used models | Delta PLC | DVP PLC series | DVP-PM | DVP10PM00M model page
External references
Delta DVP10PM instruction sheet – 28 September 2010, English/Chinese
Delta DVP-PM programming manual – 15 April 2011; model comparison PDF pages 559–560
Delta PMSoft User Manual – 21 April 2014
Delta cable guide – PM series, section 1.11.1
Delta manufacturer page – DVP10PM specifications