Delta DVP-FPMC
Delta DVP-FPMC – CANopen and Ethernet Communication Card for DVP-PM
Delta DVP-FPMC is a function card for DVP-PM motion controllers, providing CANopen motion-network communication and Ethernet connectivity. It exchanges data between the PLC and compatible servo drives, and enables program transfer and monitoring through PMSoft over Ethernet. Its role is the communication infrastructure for servo motor axes in position-control applications.
Compatibility: The comparison table in the 2011 DVP-PM manual lists FPMC support for DVP20PM00D, DVP20PM00M and DVP10PM00M. Check the CPU, card firmware and project version together. Placement in the DVP function-card family does not establish compatibility with every DVP CPU. Delta marks DVP-FPMC as discontinued in December 2020.
Specifications and axis capacity
Power: 24 V DC, −15%/+20%, supplied by the main unit through its internal bus; consumption 1.7 W. The historical manufacturer sheet lists approximately 66 g weight and a 0–55 °C operating range. Do not apply an external supply to the communication ports.
CANopen: DS301 v4.02; PDO, SDO, SYNC, Emergency and NMT messages. Supported rates are 500 kbit/s and 1 Mbit/s. The 2009 sheet specifies 100 m at 500 kbit/s and 25 m at 1 Mbit/s; branches and installation conditions require separate assessment.
Ethernet: 10/100 Mbit/s; the sheet lists a maximum cable length of 100 m. Ethernet is used for program transfer and suitable HMI communication. An Ethernet interface alone does not establish support for every industrial Ethernet protocol.
Axis distinction: Delta's product information separately lists four synchronous axes and 126 asynchronous axes through SDO. The latter is not a claim of 126 simultaneously synchronized axes. The historical 2009/2011 documents describe DS402 v2.0 and four motion axes, while the product page uses DSP402/DS402 v2.1 terminology. Verify the required function against the installed firmware.
CANopen and Ethernet wiring
Identify ports by their CANopen/Ethernet markings. Similar connector shapes do not establish electrical compatibility. Select Delta CANopen cables with the correct manufacturer pinout, shield and reference connections. Terminate the CANopen line correctly: a high-speed CAN line topology uses 120 Ω termination at both ends.
Use a suitable network cable for Ethernet; connection through an Ethernet switch is possible. Assess cable length, routing and grounding together. Do not connect the CANopen port to the computer's Ethernet port.
Programming software and connection cable
The programming tool is PMSoft. Delta PMSoft creates the DVP-PM project and supports CPU download, upload and online monitoring. The card's CANopen configuration and control-register access are handled within this project. PLC programming combines sequence-control and Ladder sections with the motion-control requirements.
Ethernet connection: Connect the PC to the DVP-FPMC Ethernet port. In the 2014 PMSoft manual, an Ethernet driver is created and started in COMMGR, then selected in PMSoft together with the station and IP address. The PC and card need compatible network settings. The older 2011 manual shows a direct “FPMC” connection option; follow the procedure for the actual PMSoft version.
Serial alternative: For the COM1 RS-232 port of DVP10PM00M/DVP20PM00D/DVP20PM00M CPUs, the cable guide lists UC-MS020-01A (2 m) and UC-MS030-01A (3 m); UC-PRG020-12A (2 m) provides PC USB connection. Install the USB-cable driver and select the correct COM port. These are CPU serial-programming connections, not CANopen field cables. The CPU's COM2 RS-485 port is a separate communication path.
Operating modes and control registers
A2 mode uses a prepared communication arrangement for suitable ASDA-A2 drives. The 2011 manual's example assigns node 127 to the FPMC master and nodes 1–4 to the four drives. In Normal mode, the user configures PDO mapping, data lengths and synchronization. Node IDs and bit rate must agree with the network configuration.
Reference registers: CR#001 is the card firmware version; CR#053 the CANopen node ID; CR#054 the communication rate; CR#056 the error status; and CR#059 the card IP/port setting. The 2014 manual defines CR#059 as three Words. These are card control registers, not direct PLC D53/D54 addresses. Implement FROM/TO access and register lengths according to the CPU/card manual.
Related function cards
For serial-communication functions, see DVP-F232, DVP-F422 and DVP-F485. For an Ethernet-card comparison, see DVP-FEN01. Their interfaces and CPU/slot requirements differ; none should be assumed to be a direct replacement for DVP-FPMC.
Editor's Note
An Ethernet link light is only a starting point when buying a used card. Check its label, CPU model, firmware and existing PMSoft project together, and back up the working system first.
Insert or remove the card with power isolated. Inspect the internal-bus connector, solder joints and port area. Measure supply voltage at verified test points; do not apply 24 V to communication pins.
Check CAN bit rate and duplicate node IDs. On an unpowered line with a 120 Ω resistor at each end, approximately 60 Ω is expected between CAN-H and CAN-L; connected circuits can affect the reading. A resistance measurement alone does not establish healthy communication.
For the first test, monitor communication and status registers while motor movement remains inhibited. If the motor will not move, check drive mode, enable, limits, homing and encoder feedback before blaming the card.
Test Ethernet and CANopen separately when only one interface works. For abnormal supply current or a short circuit, isolate the card, cable and field device to locate the fault before applying power repeatedly.
For a used-unit sale, state quantity, label photographs, working/faulty condition and the CPU used for testing. Sales require an invoice; no returns; workshop testing is available. Sellers can send details to otomasyonavm@gmail.com.
PDF documents and related topics
Visit our Delta DVP PLC files page first. This model's archive includes the DVP-FPMC instruction sheet (24 August 2009, 2 pages, English/Chinese); DVP-PM application manual (15 April 2011, 561 pages, English, chapter 13); DVP-20PM application manual (12 February 2014, 580 pages, English, chapter 11); PMSoft manual (21 April 2014, 327 pages, English); and cable selection guide (15 August 2019, 175 pages, English). Compare historical menus and functions with the installed hardware.
For the rest of the automation system, see Delta DVP PLC series, DVP expansion modules and Delta PLC.
Navigation: Delta / used equipment | DVP-PM | Function cards | DVP-FPMC model page | DVP PDF files
External references
Delta DVP-FPMC product and lifecycle information
Delta DVP-FPMC technical product information
DVP-FPMC manufacturer instruction sheet – distributor archive
DVP-20PM application manual – 2014 edition
DVP-PM application manual – 2011 edition
PMSoft user manual – April 2014 edition
Delta PLC/HMI Cable Selection Guide – 2019
CiA – CAN line topology and termination