Delta DVP20EH00R
Delta DVP20EH00R Relay Output PLC
The Delta DVP20EH00R is an original DVP-EH PLC CPU with 12 digital inputs and 8 relay outputs. It runs on 100–240 V AC and stores up to 15,872 program steps in battery-backed SRAM. On compact packaging and sorting machines, it can read sensors, push buttons and position switches, then sequence valve and motor control circuits as part of the machine’s automation program.
24 V DC inputs and encoder counting
The 12 inputs at X0–X13 use octal addressing, so X7 is followed by X10. An inductive proximity sensor can detect metal parts, a photoelectric sensor can detect passing products, and a limit switch can report end of travel. Use Delta’s wiring diagram to match the S/S input common to the 24 V DC field device’s PNP or NPN output.
Delta’s original EH high-speed counter table lists X0/C241 and X4/C242 at up to 200 kHz in single-phase mode. For A/B encoder counting, X0/X1 maps to C251 and X4/X5 maps to C252. Check the encoder output type, A/B phase order and the frequency limit for the selected mode.
Eight relay outputs and common terminals
The 20EH terminal drawing shows C0–C7 commons for relay outputs Y0–Y7. These outputs can switch an interposing relay, a contactor control circuit or a panel indicator. Delta’s legacy selection table lists 1.5 A per output. Its 2006 instruction sheet lists 2 A per output. Size loads using the unit label, the documentation matching its hardware and the load’s inrush current. Select the fuse and coil suppression for the load circuit.
Programming software and cable
Start with WPLSoft to read, back up and monitor the existing program. In the PLC programming software, select the original EH CPU type for the Ladder project. If using ISPSoft, check that the installed release includes the original EH target and configure the serial connection in COMMGR.
The DVPACAB2A30 programming cable connects the PC’s DB9 serial port to the PLC’s 8-pin Mini-DIN COM1 (RS-232) port. For a USB-only PC, fit a USB-to-RS-232 adapter with its driver at the DB9 end and select the COM number assigned by Windows.
COM2 RS-485 can connect to an operator panel or drive. Record the station address, baud rate, parity and frame format of the working Modbus link. Route encoder and communication cables away from motor wiring to reduce electrical interference.
Editor’s Note
When buying used, read the full DVP20EH00R code on the label. Look for loose or discoloured screws at C0–C7 and bent pins in COM1.
If the original CPU still runs, back up the program, retained registers and serial settings. If BAT.LOW is on, complete the backup before servicing the battery.
If the encoder counts backwards, check the A/B phase order and which counter is in use, C251 or C252, before editing the Ladder program. Test the count over a known distance.
With the machine loads disconnected, test each output on the bench with a suitable low-voltage load. If the LED lights and the load stays off, check the relevant common supply and relay contact separately.
If the PLC restarts when a contactor pulls in, measure the supply under load. Check coil suppression and cabinet grounding.
Related models and topics
In the same generation, the DVP16EH00R has 8 inputs and 8 relay outputs. The DVP32EH00R has 16 inputs and 16 relay outputs. For pulse outputs with the same 12+8 I/O count, see the transistor-output DVP20EH00T. The DVP20EH00R2 belongs to EH2, and the DVP20EH00R3 belongs to EH3. Compare terminals, expansion modules and program instructions before swapping CPUs.