What is ETL standards?

ETL product safety certification

What does the mark on a product tell you?

ETL Listed means a product has been independently tested and certified by Intertek to specific product safety standards. The ETL name comes from the history of Electrical Testing Laboratories, but ETL is not a technical standard in its own right. A standard defines requirements; a certification mark indicates the outcome of an assessment.

In the United States, Intertek is an OSHA-recognized Nationally Recognized Testing Laboratory, or NRTL. Recognition applies to standards within its approved scope. An ETL-marked product may be evaluated to an applicable UL or CSA standard. Testing to a UL standard does not mean UL issued the certification. When comparing products, check the model, standard and conditions of use before focusing on the logo.

Does ETL replace CE marking?

ETL does not replace CE marking. CE marking relates to the manufacturer's declaration that a product meets applicable European legislation; the conformity assessment procedure depends on the product category. ETL Listed is independent product safety certification. A product may carry both marks, but neither automatically satisfies the requirements associated with the other.

IEC standards and EN standards should also be distinguished from certification marks. The full standard number, edition and applicable national differences matter. Saying “it has ETL certification” leaves essential questions unanswered: which standard, which model and which market?

Reading C, US and the control number

The US identifier beside the ETL mark indicates compliance with US standards; C indicates Canadian standards. Both identifiers together indicate coverage of the applicable product safety standards for both countries. They do not identify where the product was manufactured. When checking Canadian coverage, remember that cUL is a mark issued by a different certification organization.

Look for the Intertek control number and the standard used for certification. Wording such as “Conforms to UL STD…” identifies the test standard. Before buying, search Intertek's product directory by manufacturer and exact model number, then compare the label, listing scope and technical documentation. Certification of another model from the same brand does not automatically cover your device.

Listed, Verified and the limits of certification

ETL Listed concerns product safety certification. ETL Verified confirms performance characteristics defined by the relevant verification program; this distinction is particularly useful for cabling products. Do not treat Verified as another name for Listed. The relevant record identifies the characteristics assessed.

An ETL Listed mark alone does not establish electromagnetic compatibility, FCC or RoHS compliance. An IP rating or NEMA enclosure type must also be checked against its own scope. Likewise, the suitability of a safety function under SIL requirements or EN ISO 13849 cannot be inferred from a general product safety mark alone.

How does certification work?

The process starts by identifying the product, target market and applicable standards. Technical documentation and samples are evaluated, and the required tests are performed. A certification agreement, an initial assessment of the manufacturing location and authorization to apply the mark follow. Follow-up inspections monitor whether production continues to match the evaluated design. Passing tests alone does not authorize a manufacturer to place the ETL logo on a product.

An appropriate report and certificate under the IECEE CB Scheme may support an application, subject to Intertek's review; they do not directly authorize use of the ETL mark. Changes to the design, materials, critical components or electrical ratings require assessment of their effect on the certification scope.

Editor's note: Installing an ETL-marked power supply does not automatically make the complete control panel ETL certified. Component certification applies to that model and its conditions of use; the assembled panel is a separate assessment. For example, assessment of a panel to UL 508A must be distinguished from certification of an individual device inside it.

What should you check in practice?

For example, an ETL mark on a device rated for a 230 V input does not make it suitable for a 480 V supply. Voltage, frequency, ambient temperature, protective devices and installation conditions must match the documentation. Applicable installation requirements under the NEC in the United States or the CEC in Canada must be considered separately. Certification does not make incorrect wiring or use outside the specified scope safe.