6ES7 953-8LM11-0AA0

Siemens 6ES7 953-8LM11-0AA0 – SIMATIC Micro Memory Card 4 MB

The 6ES7 953-8LM11-0AA0 is a 4 MB SIMATIC Micro Memory Card, or MMC, for suitable Siemens systems. It is intended for compatible S7-300, C7 and ET 200 devices. Check the exact device model and its supported card types rather than relying only on the shape of the slot.

The card uses 3.3 V NFlash technology. This is its operating voltage inside the device; no external 24 V supply is connected to the card. Its flash memory retains stored data through a power interruption under the specified conditions.

What does the 4 MB capacity mean?

The 4 MB rating describes the card's storage capacity. On suitable CPUs, user programs and other data can be stored in this space. The exact use depends on the device and the Siemens software involved.

Card capacity and CPU work memory are different. Inserting a 4 MB MMC does not automatically increase the CPU's work memory to 4 MB. The parts of the program that must run in the CPU must also fit within that CPU's own work-memory limits. See What is a PLC CPU? and What is a PLC? for the general concepts.

Use with the ET 200S IM151-7 CPU

The ET 200S IM151-7 CPU is an interface with its own CPU, capable of running a user program. In this device, the SIMATIC MMC serves as load memory. When the program is downloaded using STEP 7, the required program and data blocks are stored on the card; the executable portions are transferred into the CPU's work memory.

The IM151-7 manual also describes a separate function for saving project data to the memory card and retrieving it later. A working user program on the card therefore does not prove that the complete original engineering project is also present. Keep a current project backup for symbols, comments and source material. See also PLC programming software.

The 4 MB card must have enough free space for the program and any project data deliberately saved to it. Capacity is only one part of the selection: the CPU model and software version must support the card.

Use with IM151-3 PROFINET interfaces

On some ET 200S IM151-3 PROFINET interfaces, the MMC is used to carry station data such as the device name or firmware update data. It is not being used in the same way as the program card in an IM151-7 CPU. For example, Siemens lists the 4 MB 8LM11 among the available cards in the manual for the IM151-3 PN High Feature 6ES7 151-3BA22-0AB0.

In the relevant IM151-3 PN description, Siemens specifies use of a card for device data or firmware update data. Do not assume that existing content will be preserved when preparing an update card. Choose and handle the card according to the station manual and maintenance plan. The general network principles are covered under PROFIBUS and PROFINET.

Not every IM151 interface uses an MMC in the same way. An IM151-7 CPU and an IM151-3 PROFINET interface have different roles. Check the order number and card slot against the documentation for the actual interface. Other models are listed under ET 200 communication modules.

S7-300, C7 and ET 200M applications

Siemens lists this card for suitable S7-300 / C7 / ET 200S devices. A Siemens CPU 315T-2 DP application document, for example, uses the 4 MB 8LM11 card to store the S7 program. The C7-636 manual also lists this order number among its supported MMC options. Do not assume that every S7-300 or C7 model accepts the same capacities; check the exact device and its manual.

The card can also be used for a firmware update on certain suitable ET 200M IM153-2 versions. The relevant method can, for example, be considered for the IM153-2BA00 interface. In this application the card does not turn the IM153-2 into a standalone PLC CPU. Writing update files can overwrite the card's previous contents, so preserve any required data first.

Differences between similar cards

The complete order number of this product is 6ES7 953-8LM11-0AA0, with a capacity of 4 MB. In Siemens' list for the same generation, 6ES7 953-8LL11-0AA0 is 2 MB, while 6ES7 953-8LP11-0AA0 is 8 MB. The numbers are similar, so check the LL, LM and LP letters on the label carefully.

A different capacity or generation should not be assumed compatible with every device merely because it looks similar. Verify the capacities and card versions supported by the actual CPU or interface. Other products are listed under used memory cards.

Replacing the card and protecting data

Inserting a blank MMC does not automatically transfer the machine program to the new card. Before replacement, identify the purpose and content of the existing card and, where possible, make a current backup of the application and engineering project. The correct program or device data must then be loaded to the new card using the applicable Siemens method.

Do not remove the card while the CPU is in RUN. The Siemens IM151-7 CPU manual describes switching the CPU to STOP and checking that no write operation is in progress before replacing the card. The IM151-3 PN High Feature manual requires the card to be inserted and removed with the power off. Follow the instructions for the installed device and place the machine in its appropriate safe state.

Some CPUs may request or automatically perform a memory reset after a card change under certain conditions. Check the relevant CPU manual for its effect on the program and retentive process data. A memory-reset request does not automatically mean that the card needs formatting.

Do not format it with Windows

Siemens explicitly states that the SIMATIC MMC must not be formatted using Windows or third-party devices. Doing so can overwrite the card's internal SIMATIC structure. Reading, writing, updating or any necessary formatting must follow the Siemens method defined for the device and software in use.

Formatting or writing firmware files can erase existing data. Before working on a problematic card, establish whether it holds a machine program, device name or other required information. The general troubleshooting sequence is also discussed under PLC debugging.

Retaining a program on the card does not mean that every live process value is automatically saved. The behaviour of current and retentive data depends on the CPU, the application and the operation performed.

Checking a used card

Inspect the complete order number, the housing for cracks or distortion and the condition of the contacts. Before testing or erasing a used card, establish whether its existing contents are needed. Flash write and erase life is limited; the past usage of a used card usually cannot be determined from its label.

This product is not an ordinary microSD card. A card made for a phone or camera should not be assumed to replace a SIMATIC MMC because it appears similar. Cards from other SIMATIC generations also require a check against the device's supported-parts list.

Editor's Note: Before asking how many megabytes are needed, establish which device will use the card and for what purpose. An IM151-7 CPU card may hold a program; an IM151-3 PN interface may use it for the device name or update data. Check the existing content and backup before replacing, updating or formatting a card. In particular, do not format a card from a working machine with Windows.

Manuals and related topics

For IM151-7 CPU, IM151-3 interface and ET 200M details, visit Siemens ET 200 manuals and PDF files. The station overview is available on About Siemens ET 200.

Related topics: Used PLC CPUs · S7-300 CPU modules · PLC questions · Memory questions

Navigation: Siemens automation · SIMATIC S7 · Siemens ET 200 · OtomasyonAVM homepage