6ES5 418-8MB11
Siemens 6ES5 418-8MB11 – ET 200K Compact Remote I/O Station
Siemens 6ES5 418-8MB11 is an IP65 ET 200K remote I/O station with an integrated SINEC L2–DP interface. It belongs to the Siemens ET200 family and is listed among S5 interface modules. This version uses PG cable glands; maintaining IP65 protection requires intact seals and correctly fitted glands.
It provides 16 fixed digital inputs, 8 fixed digital outputs and 8 individually configurable input/output channels. In this mixed digital I/O arrangement, A/B are inputs, C is outputs and D is configurable. Record the D0–D7 directions before replacing the station.
Channel allocation and field signals
Record the digital input and digital output points alongside the cable numbers. A D terminal used as an input in one project may serve as an output in another. Read the existing configuration before transferring the wiring.
Establish the difference between digital and analog signals before making connections. When selecting a sensor or inductive proximity switch, compare its supply, output circuit and wiring diagram. The number of wires alone does not establish compatibility.
24 V DC supplies and output loads
The nominal supply is 24 V DC, with a permitted range of 20–30 V DC. L1 powers the internal circuits and sensors, L2 supplies the C outputs, and L3 supplies D channels configured as outputs. Limits are 0.5 A per output and 4 A total for each output group, C and D.
When reviewing ET200 power supplies and power distribution, assess each group with its own load. Measure the relevant supply terminals while outputs are operating, rather than relying solely on an unloaded voltage reading.
SINEC L2–DP and station configuration
The manufacturer’s manual describes connection through an IM 308-B master and configuration with COM ET200. For PROFIBUS communication, check that the replacement agrees with the master project. Distinguish this SINEC L2–DP station from current ET200 PROFIBUS/PROFINET products when planning connections.
Valid station addresses are 3–124; RESET returns the address to 126. In addition to backing up the PLC program, record the station address, D-channel directions and diagnostic settings. Use the project’s station definition when commissioning the ET200 system.
Diagnostics and controlled channel tests
BF indicates a bus fault; DIA indicates a diagnostic summary. During troubleshooting, record the LEDs together with the master diagnostics. A single indicator is not enough evidence to condemn the complete station.
The ET200 Handheld supports address changes, D-channel configuration, status monitoring and output forcing. Disconnect the station from the active SINEC L2–DP network before connecting the handheld. Arrange the loads so that output tests cannot cause unintended movement.
Cable glands and installation checks
Here, PG identifies the cable-gland connection version. Photograph cable labels and terminal numbers before opening the housing. Inspect glands, seals and plugs in unused entries. When checking S5 connecting cables, compare the actual terminal arrangement with the wiring diagram.
Include protective grounding and shield connections in the inspection. When investigating electromagnetic interference, examine cable routes and termination points. Check that no cable is trapped across the seal when refitting the cover.
Editor’s note
Start with the label and the connection arrangement side by side. 8MB11 is the PG cable-gland version. Check the existing wiring before beginning the replacement, even if the housings look alike. A few clear photographs are worth keeping.
If the station is running but the loads do not operate, take a moment before looking for a replacement. Measure L1, L2 and L3 separately under load. Write down the readings so the next decision rests on a clear comparison.
Give the D group its own record. Write down whether each channel, D0–D7, is an input or an output, then compare that list with the field wiring. Eight short entries can prevent a surprisingly confusing replacement job.
In a Siemens S5 system, a reliable address and project record is valuable. Do not press RESET simply hoping communication will recover. Record the current address, master settings and BF status first; preserve the information you already have.
When buying a used Siemens station, ask for more than a photograph showing power applied. Test inputs and outputs separately, and inspect the glands, cover seal and internal terminals. A written record of the signal or load used for each test makes the result much easier to assess.
OtomasyonAVM resources and PDFs
+ Siemens ET200 and S5 interface modules: related station and interface groups.
+ Siemens ET200 user manuals · Siemens S5 shared PDF archive. The German ET 200K station manual and English Handheld manual are identified separately in the manufacturer references below.
Related topics
+ ET200 digital inputs · ET200 digital outputs · ET200 power distribution
+ 6ES5 308-3UB11 / IM 308-B: master interface. 6ES5 418-8ME11 is the plug-connector ET 200K version; assess the connection arrangement before treating it as a direct replacement.
Browse SIMATIC S5
+ Siemens ET200 · S5 interface modules · SIMATIC S5
+ Siemens S5 PLC · Siemens second-hand equipment
Siemens and external references
+ Siemens ET 200 Handheld Manual – English; 6ES5 998-7ET21, EWA 4NEB 812 6096-02b. Chapter 3 covers connection conditions; chapter 8 covers ET 200K addressing, D channels and testing.
+ Siemens ET 200K station manual – German; 6ES5 998-6ET11, EWA 4NEB 812 6088-01. Section 1.2 identifies the 8MB11/8ME11 variants and I/O arrangement; chapter 4 covers configuration; Appendix A gives electrical limits.