6ES5 391-5AA12
Siemens 6ES5 391-5AA12 — Operator Panel for the 390 Timer/Counter
Siemens 6ES5 391-5AA12 is an operator panel for the SIMATIC S5 390 timer/counter module. Its role in a Siemens S5 installation is to let the operator view and adjust timing and counting values. Assess this auxiliary panel together with the 390 timer/counter board; the timing and counting capacity belongs to that module, not to an independent PLC inside the panel.
The 391 is a numerical operating interface for S5 special modules. It should not be described as a modern graphical HMI or the TD 390 text display. Identify the installed 390 board, connection assembly and complete panel revision before selecting a replacement for the PLC system.
Numerical display and value entry
Siemens ST 53 describes address/value selection, actual and preset value display, preset entry and next-address selection for the 391-5 family. The 0–15 LEDs in its family drawing indicate operation of the corresponding timers; they are not general digital-input indicators. In a timing application, read the selected address together with the displayed value.
For example, before changing a waiting period, select the correct timer, record the existing preset and confirm that the new value reaches the intended address. Do not infer time units or machine functions from the number alone without checking the programming records.
390 module, CPU and addressing
Siemens’ catalogue shows the 391-5 family with the 390 module in S5-130A/130K arrangements. Check the S5 CPU, rack configuration and exact 390 part number together. The S5 name alone does not establish a direct connection to every controller in the range.
The timer/counter address selected at the panel is different from a channel address on a digital input board or a byte address on a digital output board. Nor does the panel’s role establish a high-speed counter input rating; counting specifications must be checked for the connected 390 module.
Connecting cable and revision checks
The ST 53 family arrangement shows a 1.5 m cable connection to the 390 board, while its ordering entry identifies 391-5AA13. Verify the cable, enclosure and connector match on the actual 5AA12 assembly. For S5 connecting cables, orientation, retention and conductor continuity matter alongside connector shape.
Do not apply external voltage to unidentified contacts without a verified 5AA12 supply specification and pin assignment. Keep protective-earth and signal connections distinct, following the label and relevant drawing. Similar connectors do not establish RS-232, MPI or Ethernet compatibility.
Keypad, display and functional testing
During fault-finding, an illuminated display is only a starting point. Test the number keys, clear function, address increment and value-selection functions individually in a suitable system. Missing display segments or a key that registers twice can lead to an incorrect setting.
System checks through a programmer interface do not replace testing the panel’s connection to the 390. Record existing parameters and preserve program memory and backups before making changes. During Siemens S5 maintenance, keeping the panel, cable and 390 board identities together makes later diagnosis easier.
Differences from 5AA13 and other S5 panels
6ES5 391-5AA13 is catalogued as a 391 panel with enclosure. 6ES5 393-0UA11 and 6ES5 395-0UA11 are other S5 operator-panel types. A shared brand or panel description does not guarantee the same cable or operating method. For a used unit, inspect the complete 6ES5 391-5AA12 label, front face, rear connection and supplied cable together.
Editor’s note
Ask to see the panel working with a suitable 390 board. An illuminated display is useful, but address selection and value reading still need to be demonstrated.
Test each key separately. Double entries or intermittent response can produce an incorrect time setting. A key that works only under heavy pressure should not pass as healthy.
Inspect the display carefully from the front. A missing segment can make one digit resemble another. Check the display before treating the symptom as an operator-setting error.
Record the original value and selected address before changing a timer or counter preset. Use controlled test conditions, then read back the result rather than experimenting with a running machine’s settings.
Treat the panel, matching cable and 390 board as a working assembly. A missing cable matters. Isolate power for connection changes and handle aged connectors without forcing them.
OtomasyonAVM resources and PDFs
Browse the 6ES5 391-5AA12 model page, S5 auxiliary modules and used Siemens equipment. General documents are collected in the shared Siemens S5 PDF archive, not presented as a dedicated 5AA12 pin-assignment or service sheet.
Related topics
+ 6ES5 390-5AA22 — related timer/counter module.
+ 6ES5 391-5AA13 — 391 revision catalogued with enclosure.
+ 6ES5 393-0UA11 — a different S5 operator panel.
+ 6ES5 395-0UA11 — another S5 panel type.
+ Derell timer relays — for separate timing applications, not direct replacements for the 391 panel.
Browse SIMATIC S5
S5 auxiliary modules · S5 special modules · S5 cables · SIMATIC S5 · Siemens S5 PLC · Used Siemens equipment
Siemens and external references
Siemens ST 53 — SIMATIC S5-130 / S5-150, 1985 — 391-5 family operation: printed p. 2/7 / PDF p. 21. Connection distance: p. 8/3 / PDF p. 89. Ordering entry: p. 9/2 / PDF p. 120, identifying 391-5AA13. Not a substitute for a verified 5AA12 electrical pin assignment.
Allmendinger — 6ES5 391-5AA12 — Commercial parts record identifying the exact code as an operating panel for module 390, not a manufacturer service manual.