6ES5 373-0AA61

Siemens SIMATIC S5 6ES5 373-0AA61 64 KB Long-Format NMOS EPROM

The Siemens 6ES5 373-0AA61 is a 64 KB long-format NMOS EPROM for SIMATIC S5. This 373-series memory submodule holds 32 K 16-bit words. In an S5-155U, it fits the 6ES5 355-3UA11 memory carrier to expand user program storage for the CPU 946 or CPU 947.

A WF 470 display module uses the EPROM to store screens and text. The 373-0AA41 holds 32 KB and the 373-0AA81 holds 128 KB. The 373-1AA61 also holds 64 KB and uses CMOS EPROM. Siemens gives programming number 0060 for the 0AA61 and 0460 for the 1AA61 in the WF 470 table.

355 carrier and CPU compatibility

One 355 carrier accepts up to three long-format memory submodules. Siemens lists the same carrier in the S5-155H for user program storage with the CPU 946R and CPU 947R. At startup, the CPU 946/947 identifies the installed submodules and assigns EPROM addresses in descending order.

Check the CPU and carrier together when selecting a spare. The S5-135U manual specifies short-format 376 EPROMs for older CPU 928 installations. The 374-series Flash EPROM cards listed for the CPU 948 belong to a separate memory family.

WF 470 memory sockets

Siemens lists the 0AA61 for the WF 470 X10, X20 and X30 memory sockets. Enter 0060 as PNUMMER in the picture generation software. The same table assigns separate numbers to the 32 KB CMOS 373-1AA41 and 128 KB CMOS 373-1AA81.

The WF 470 A and B require at least one RAM submodule for commissioning. The WF 470 C has built-in CMOS RAM for this purpose. Record the existing socket positions and save the screen project before removing a card.

Programming mode and backups

The Siemens STEP 5 table lists programming number 60 and a 4 × 27128 EPROM configuration for the 0AA61. Select WORD/FIELD for the 355 carrier. The PG 615 manual lists the order number for the S5-150S and specifies word-oriented handling from software version 1.3.

Read the EPROM into a file with a compatible S5 programming device. This UV-erasable EPROM retains its contents without power. Use the S5 PG connection for an online backup from the running CPU. Keep the EPROM and CPU backups in separate files.

Editor’s note

Verify the 373-0AA61 order number and 64 KB capacity together. The 1AA61 holds the same amount of data and uses a different programming number.

Isolate the rack supply before removal. Record the CPU order number, 355 carrier slot and submodule order.

Save the EPROM copy and running system backup separately. Verify that the EPROM copy can be opened before erasing the submodule.

If screens are missing on the WF 470, check the X10/X20/X30 socket positions and the screen project on the card first. On the A and B versions, also verify the RAM submodule required for commissioning.

For a used card, ask for a read test with programming number 60. After programming, compare the contents with the source file.

OtomasyonAVM resources and PDFs

+ SIMATIC S5 memory submodules · Siemens SIMATIC S5 PLC overview

+ SIMATIC S5 PDF archive · S5-115U manuals

Related topics

+ 6ES5 373-0AA41 32 KB EPROM · 6ES5 373-1AA61 64 KB CMOS EPROM · 6ES5 373-0AA81 128 KB EPROM

S5 navigation

+ S5 memory cards · SIMATIC S5 · Siemens S5 PLC

External references

+ Siemens S5-155U CPU 946/947 manual · 355 carrier and EPROM submodules

+ Siemens WF 470 Technical Description · Memory sockets and PNUMMER

+ Siemens STEP 5 manual · Table 11.1, EPROM programming numbers (DE)

+ Siemens PG 615 manual · Table 2.9, S5-150S and word operation (DE)