6ES5 095-8FA02
Siemens 6ES5 095-8FA02 SIMATIC S5-95F Subunit
The Siemens 6ES5 095-8FA02 is one of the two subunits that make up a SIMATIC S5-95F fail-safe PLC system. An S5-95F pair requires two units with the same order number and hardware revision. See the Siemens S5 PLC guide for the series and the used PLC CPU section for other units.
Fibre-optic link and power supply
Subunits A and B are connected by a fibre-optic cable. DIP switches below the optical connector set the A/B identifier and cable length. When looking for S5 cables, check the order number of the existing fibre-optic cable. The rated supply is 24 V DC, with a permissible range of 20–30 V DC including ripple. Siemens allows two 8FA02 subunits to share a PLC power supply that meets the manual’s electrical isolation and supply requirements.
Onboard I/O and expansion
An A/B pair provides 16 fail-safe digital inputs (I32.0–I33.7) and eight fail-safe digital outputs (Q32.0–Q32.7) at system level. Each subunit also has four standard single-channel outputs. The system provides four interrupt inputs and two counter inputs. Onboard digital I/O uses a 40-pin front connector. When checking S5 digital input and S5 digital output modules, check onboard and external module addresses separately.
Siemens lists the safety-related 6ES5 431-8FA11 digital input module and the 6ES5 700-8FA11 bus unit among the S5 expansion modules. Record the functions and slot addresses of any standard digital I/O modules installed in the cabinet. Check external modules used for safety functions against Siemens’ hardware list.
STEP 5, COM 95F and EPROM
The STEP 5 program is transferred through the PG interface. Check the programmer interface when selecting a programming cable. The subunit has 16 KB of internal RAM, with 8 KB allocated to the user program. Safety mode requires two matching memory submodules, one per subunit. The program and DB1 are stored on these EPROM submodules. COM 95F V2.1 and V7.01 can parameterize the 8FA02. Use the parameters permitted for this hardware.
If the installation uses SINEC L2, check the order number of the S5 communications interface. Siemens lists the 8FA02 from hardware revision 01 for safety-related communication through the CP 541. The manual specifies 115F-15 message mode for this connection.
Used equipment checks
Check the label for 095-8FA02 and the hardware revision. The similarly numbered S5-95U 095-8MA04 is a separate model. Inspect the electronic board and front connector for rework or corrosion. Ask whether the memory submodules and fibre-optic cable are included. To reduce the risk of data loss, archive the STEP 5 program and COM 95F parameter printout before replacement.
Editor’s note
When buying one subunit, compare its full order number and revision with the label of the unit staying in the cabinet. If buying a pair, ask for photos of both labels and a COM 95F diagnostic printout from the A/B pair. Complete the installation’s safety validation before returning it to service.
If you have this unit for sale, send photos of the unit and its label to otomasyonavm@gmail.com.
Siemens S5 PDF archive
See the shared Siemens S5 PDF archive for manuals and technical documents.
Related topics
6ES5 095-8FA01 · 6ES5 095-8FB01 · SIMATIC S5 CPU models
References
Siemens S5-95F System Manual · EWA 4NEB 812 6210-02a, edition 02 · 8FA02 power supply, p. 4-4 · Onboard I/O, p. 4-7 · 8FA02 technical data, p. A-2.