Siemens SIMATIC S5-95F 6ES5 095-8FB01 Failsafe PLC Subunit

The 6ES5 095-8FB01 is one PLC subunit for the dual-channel S5-95F failsafe system in the Siemens SIMATIC S5 family. Subunits A and B operate as a matched pair in the safety application.

Matching subunits A and B

Siemens requires both subunits to have the same order number and hardware revision. A fiber-optic cable links A and B. The Siemens example system uses the 1 m fiber-optic cable 6ES5 722-1BB00. Check that exact part number when reviewing S5 cables and connectors.

The 6ES5 095-8FA01 and 6ES5 095-8FA02 are earlier S5-95F variants. The 8FB01 supports two-out-of-three evaluation for failsafe digital inputs. The 6ES5 095-8MA05 belongs to the standard S5-95U compact CPU series.

Power supply, front connector and onboard I/O

Each subunit takes a nominal 24 V DC supply, with an allowable range of 20–30 V DC. Siemens lists the 40-pin 6ES5 490-8FB11 front connector for onboard digital signals. The subunit measures 145 × 135 × 146 mm. The Siemens mounting example uses the 6ES5 710-8MA11 DIN rail.

The dual-channel system has 16 failsafe digital inputs at I32.0–I33.7 and 8 failsafe digital outputs at Q32.0–Q32.7. It also has four failsafe interrupt inputs and two failsafe counter inputs. Each subunit additionally provides four single-channel standard digital outputs. When comparing existing digital input and digital output circuits, check the A/B terminal assignments in Section 4.7 of the manual.

External modules and expansion

Documented S5-95F expansion modules include the 6ES5 431-8FA11 failsafe digital input module and the 6ES5 450-8FA11 / 8FA12 failsafe digital output modules. For safety-related 4–20 mA processing, Siemens documents specific circuit and evaluation configurations using the 6ES5 464-8MG11 analog input module. Standard S5 analog modules can serve standard measurement tasks.

When documenting an existing expansion, record the labels on the 6ES5 700-8FA11 bus unit and the IM 316F 6ES5 316-8FA12 interface, where fitted. Check module order and addresses against the COM 95F parameters.

STEP 5, COM 95F and memory

The control program uses STEP 5. COM 95F handles system parameters, signal groups and fault diagnostics. Internal RAM is 16 KB, with 8 KB for the control program. In the operating mode Siemens calls Safety Mode, A and B use two EPROM submodules with the same order number. The manual describes communications modules such as the CP 521 SI for standard tasks such as logging event messages.

Editor’s Note

Before buying a used 8FB01, get label photos of the spare and the mating subunit that will remain in the machine. Compare the full order number and hardware revision side by side. Record the condition of the fiber-optic socket and the EPROM labels. Back up STEP 5 and COM 95F data before a reset or replacement. After loading the program, qualified personnel should complete the CRC signature comparison and safety acceptance test.

To sell a used 6ES5 095-8FB01, send the quantity, working condition or fault details, a label photo and your asking price to otomasyonavm@gmail.com.

Related topics

S5 communications modules | S5 interface modules | S5 bus units and racks

Navigation

Shared SIMATIC S5 PDF archive | S5 CPU 90U–115U | Used SIMATIC S5 | Siemens second-hand main page | Second-hand automation

References

Siemens S5-95F system manual (PDF, EN) · EWA 4NEB 812 6220-02, Edition 01. Model and revision scope on p. xix, onboard I/O on p. 4-7, terminal assignments on pp. 4-31–4-32 and technical data on p. A-5.

Siemens COM 95F parameterization manual (PDF, EN) · EWA 4NEB 812 6221-02a. Parameters, fault diagnostics and acceptance tool in Chapters 2, 3 and 5.

Siemens 8FB01 product information supplement (PDF, EN) · A5E00076820-01, 08/2000. Operating modes and program signature verification on pp. 3–4.