VAT 3FD VFD

Hi everyone,

General Electric 3VFD Series VFD:

Control system: All-digital sinusoidal PWM system
Carrier frequency: 3-8kHz (Arbitrarily selected with 1kHz units)
Output frequency resolution: 0.01Hz
Frequency setting resolution: Digital setting input: 0.01Hz, Analog setting (external) input: 0.1% of maximum frequency
Frequency accuracy: Digital setting: ±0.01% (25ºC±10ºC), Analog setting: ±0.5% (25ºC±10ºC)

Control specifications:
Voltage/Frequency characteristics: Constant torque, constant power, and reduced variable torque. Each can be set arbitrarily in the range of 3-440Hz. Selection by preset patterns are also available.
Torque boost: Auto/Manual selection available. Range of setting boost: 0.0-20.0%, square low: 0.0-25.0%
Start frequency: 0.1-60.0Hz (1.0Hz for standard)
Starting torque: 150% or more
Accel./decel. time: 0.01-60,000 sec (accel./decel. set separately). In addition to two sets of acceleration/deceleration time, eight sets of acceleration/deceleration time can be selected. There is acceleration/deceleration time available exclusively for inching operation.
Accel./decel. mode: Linear/S shape characteristics accel. and decel. selection available

Operation system:
3-mode selection available
- Forward reverse run
- Operating and revolving directions
- Forward operation pulses/reverse operation pulses/stop, Inching operation available

Stopping system: Ramp down stop/coast-to-stop stop selection possible. Deceleration and stop with each command for run, emergency stop, and inching.
DC brake: DC brake starting frequency: 0.1-60.0Hz/braking voltage: 0.1-20% braking time: 0.1±20 sec, arbitrarily set.

Operation specifications:
Pattern operation: Multi-step setting: 8 steps, accel./decel. time selection possible at the same time
Interlock ratio: In the case of remote operating mode F = AX + B + C X: Frequency setting input, C: AUX-input F: Output, A: ±0.001-10.000, B: ±0.00-440Hz
Frequency limit: Upper/lower limit setting possible of F (above)
Frequency skip: 3-position setting (Jumping width can be arbitrarily set for each Skip frequency in a range of 0.1-10Hz.)
Slip compensation: Selection of operation/no-operation is possible.
Pattern-run function: Pattern-run is possible in 10 steps. Synchronization (process stepping)/asynchronization (internal timer operated) is possible.
Other functions: PID control, pick-up, auto-start, instantaneous power failure restart, reverse run prevention, traverse pattern for fiber machine.

External I/O:
Operation panel: 5-digit 7-segment LEDs: 8 mode/unit lamps. Local/remote selection possible, forward/reverse run operate selection possible. Reference and updating can be applied for all parameters. (Prevention of panel operation can be set.)

Sequence input: Forward/reverse run, emergency stop, fault reset, 5 point programmable inputs

Sequence output: Fault (relay 1-c contact), run (relay 1-a contact). In addition to the above, changeover to the following internal status signals is possible for operation and speed attainment: READY TO RUN, END OF PRELIMINARY CHARGING, REVERSE RUN, DIRECT OPERATION, CURRENT DETECTION .


+ VAT-3FD Control Functions and Parameter Settings  (pdf)

+ VAT-3FD Control Input-Output  (pdf)

+ VAT-3FD INSTRUCTION MANUAL  (pdf)

+ VAT-3FD option-fault codes  (pdf)


+ General Electric 2. Main page >

+ VFD Homepage


-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  22.01.2013 