Toshiba VF-AS1

The Toshiba VF-AS1 series has been discontinued and is now classified as a legacy drive series.
Toshiba VF-AS1 AC Drive is a high-performance variable frequency drive designed for demanding industrial motor control applications. The series combines a wide output frequency range with advanced V/f control, sensorless vector control, torque control, PID functions, preset speeds and automatic restart capabilities.
Control system: Sinusoidal PWM control.
Output voltage control: Main-circuit voltage feedback control. The function can be switched between automatic adjustment, fixed control and control OFF.
Output frequency range: 0.01 to 500 Hz. Maximum frequency can be adjusted from 30 to 500 Hz.
Minimum frequency setting resolution: 0.01 Hz from the operation panel at a 60 Hz base frequency, and 0.02 Hz from an analog input at a 60 Hz base frequency using an 11-bit, 0–10 VDC signal.
Frequency accuracy: Analog input: within ±0.2% of maximum output frequency at 25°C ±10°C. Digital setting: within ±0.01%.
V/f characteristics: Constant V/f control, voltage-reduction characteristics, automatic torque boost, sensorless vector control and 5-point custom V/f characteristics are supported. Base frequency settings 1, 2, 3 and 4 can be adjusted from 25 to 500 Hz. Manual torque boost can be set from 0 to 30%, start frequency from 0 to 10 Hz and stop frequency from 0 to 30 Hz.
Frequency reference signal: A 3 kΩ potentiometer can be used, and potentiometers rated between 1 and 10 kΩ can also be connected. Supported analog references include 0–10 VDC with 30 kΩ input impedance, 0 to ±10 VDC with 22 kΩ input impedance, and 4–20 mA with 242 Ω input impedance.
Frequency reference inputs: The input characteristic can be scaled using two-point adjustment. Supported reference inputs include RR, VI/II, RX and RX2 analog inputs, pulse input and binary/BCD input. RX2 and binary/BCD inputs require the applicable optional hardware.
Frequency jump: Three independent jump-frequency points can be configured together with their respective frequency widths.
Upper and lower frequency limits: The upper limit can be set from 0 Hz to the maximum frequency. The lower limit can be set from 0 Hz up to the selected upper limit frequency.
PWM carrier frequency: For 200 V models up to 45 kW and 400 V models up to 75 kW, the carrier frequency can be adjusted from 1.0 to 16 kHz. For 200 V models from 55 kW and 400 V models from 90 kW, the adjustment range is 2.5 to 8 kHz.
PID control: Proportional gain, integral time, differential time and delay-filter settings can be configured for process control applications.
Torque control: Torque reference can be supplied as a DC 0 to ±10 V command signal.
Acceleration and deceleration: Acceleration/deceleration time can be adjusted from 0.01 to 6000 seconds. Four independent acceleration/deceleration time sets are available. The drive also supports automatic acceleration/deceleration and two selectable S-pattern acceleration/deceleration characteristics. More information is available on our acceleration and deceleration time page.
DC braking: DC braking start frequency can be set from 0 to 120 Hz, braking level from 0 to 100% and braking time from 0 to 10 seconds. Emergency-stop braking and motor-shaft holding functions are also available. DC injection braking is different from braking performed through an external braking resistor.
Forward and reverse operation: Closing F-CC commands forward rotation, while closing R-CC commands reverse rotation. If both F and R commands are active simultaneously, the drive stops. Opening ST-CC produces a coast stop. Emergency stop can be initiated from the operation panel or through the terminal board.
Jog operation: When jog mode is selected, low-speed jog operation can be performed directly from the operation panel. Jog operation through the terminal board can also be configured by parameter settings.
Preset-speed operation: By changing the ON/OFF combinations of S1, S2, S3 and RR/S4-CC, the VF-AS1 can operate at the main frequency reference plus 15 preset speeds. Acceleration/deceleration time, torque limit and V/f characteristics can be assigned according to the selected speed.
Automatic retry: If a protective function trips the drive, the VF-AS1 can check the main-circuit condition and attempt an automatic restart. Up to 10 retry attempts can be selected, with a waiting time adjustable from 0 to 10 seconds.
Soft Stall: During an overload condition, automatic load-reduction control can reduce the load and help prevent a protective trip. The function is disabled by default.
Cooling-fan control: The cooling fan can stop automatically when cooling is not required, reducing noise and extending fan service life.
Operation-panel key lock: Individual keys such as STOP or MODE can be disabled, or all keypad operations can be prohibited to prevent unauthorized changes.
Regenerative power ride-through: During a momentary power interruption, the VF-AS1 can use the motor's regenerative energy to help maintain operation. This function is disabled by default.
Automatic restart and speed search: The drive can detect the speed and direction of a coasting motor and smoothly regain control without requiring the motor to come to a complete stop. This function is disabled by default.
Simplified pattern operation: Two groups of eight operating patterns can be selected from the 15 preset-speed frequencies, providing up to 16 operating patterns. Terminal-board operation and repeated pattern operation are supported.
Utility power / inverter transfer: Operation can be switched between the commercial power supply and inverter operation, allowing the drive to be integrated into bypass and transfer-control systems.
Light-load high-speed operation: When the mechanical load is light, the drive can automatically increase motor speed to improve machine operating efficiency.
Droop control: In applications where two or more drives share a common mechanical load, droop control helps prevent the load from becoming concentrated on a single motor or inverter.
Override function: An external input signal can be used to apply an offset or adjustment to the operating-frequency command.
Protective functions: The VF-AS1 provides protection against stall conditions, current limiting, overcurrent, overvoltage, load-side short circuit, load-side ground fault, undervoltage, momentary power interruption, inverter overload, motor overload, starting overcurrent, braking-resistor overcurrent or overload, overheating and emergency-stop conditions.
Electronic thermal protection: Protection characteristics can be selected for standard motors or constant-torque inverter-duty motors. Motor overload protection and stall-prevention levels can also be adjusted.
Alarm indications: Available indications include stall prevention, overload limit, overload, supply-side undervoltage, DC-bus undervoltage, parameter-setting error, retry operation, upper frequency limit and lower frequency limit.
Trip and fault diagnostics: Diagnostic functions cover conditions including overcurrent, overvoltage, overheating, load-side short circuit, load-side ground fault, inverter overload, starting overcurrent, CPU, EEPROM, RAM and ROM errors, communication errors, braking-resistor overcurrent or overload, emergency stop, undervoltage, undercurrent, overtorque, motor overload, input phase loss and output phase loss. Some protective functions are parameter-selectable.
Monitoring functions: The VF-AS1 can monitor operating frequency, frequency command, forward/reverse status, output current, DC-bus voltage, output voltage, compensated frequency, terminal input/output status, CPU version, trip history, cumulative operating time, speed feedback, torque, torque command, torque current, excitation current, PID feedback, motor overload ratio, inverter overload ratio, braking-resistor load, input power, output power, peak output current and peak DC-bus voltage.
Additional monitored values include RR/S4, VI/II, RX and optional analog inputs, FM and AM outputs, expansion I/O option status, accumulated input/output energy and communication counters.
Free-unit display: Values other than output frequency can be displayed using application-specific units such as motor speed or line speed. Current can be displayed in amperes or percent, and voltage in volts or percent.
Automatic parameter search: The drive can automatically identify parameters whose values differ from the standard factory settings, making modified parameters easier to locate during commissioning, troubleshooting and maintenance.