6ES7 135-4MB02-0AB0

Siemens product menu:
Siemens Automation  ›  SIMATIC S7 PLC  ›  Siemens ET 200  ›  ET 200 Manuals and PDF Files

6ES7 135-4MB02-0AB0 – Siemens ET 200S 2AO I High Feature Analog Output Module

6ES7 135-4MB02-0AB0 is a two-channel, high-resolution analog current output module for Siemens SIMATIC DP ET 200S stations. It converts digital values from the PLC program into ±20 mA or 4–20 mA field signals for drives, proportional valves, positioners and process-control equipment.

The product belongs to the electronic-module family used in Siemens ET 200 distributed I/O systems. For wider system information, see the Siemens ET 200 system overview and the analog input and output guide.

The “I” Matters: This Is a Current Output Module

The 2AO I designation means two analog current outputs. This module does not provide 0–10 V or ±10 V voltage outputs. A 2AO U version is required when the receiving device expects a voltage reference. It must not be selected merely because the application calls for “two analog outputs.”

Signal type, resolution, cycle time, diagnostics and terminal arrangement must be compared before replacement. Related products can be found under ET 200 analog input modules, ET 200 output modules and ET 200 special output modules.

Principal Technical Data

Product type: 2AO I High Feature analog electronic module
Article number: 6ES7 135-4MB02-0AB0
System: SIMATIC DP ET 200S
Number of analog outputs: 2
Output type: Current
Output ranges: ±20 mA and 4–20 mA
Resolution: 15 bits plus sign for ±20 mA; 15 bits for 4–20 mA
Cycle time for all channels: Maximum 0.5 ms
Address space: 4 bytes
Rated load/electronics supply: 24 V DC
Current consumption from L+: Maximum 80 mA
Consumption from 3.3 V backplane bus: Maximum 10 mA
Module power loss: Maximum 1.2 W

Permissible current-output load: Maximum 500 Ω
Inductive load: Maximum 1 mH
Open-circuit output voltage: Maximum 18 V
Shielded cable length: Maximum 200 m; maximum 100 m when TWA is below 2 ms
Basic error limit: Approximately ±0.05% of output range at 25 °C
Operational error limit: Approximately ±0.1% over the temperature range
Dimensions: 15 × 81 × 52 mm
Weight: Approximately 40 g
Diagnostic indication: Red SF group-fault LED

What High Feature Means

The High Feature designation identifies a combination of high resolution, fast update, readable diagnostics, parameterised substitute values, I&M identification data and support for isochronous operation. Availability of these functions also depends on the hardware and firmware version of the selected ET 200 PROFIBUS or PROFINET interface module.

A 0.5 ms module cycle does not mean that the complete station and PLC program automatically update in 0.5 ms. The interface module, bus cycle, controller program and other ET 200 electronic and additional modules must be considered together.

SIMATIC S7 Analog-Value Scaling

In the ±20 mA range, a PLC value of −27648 represents approximately −20 mA, 0 represents 0 mA and +27648 represents +20 mA. In the 4–20 mA range, 0 represents 4 mA, 13824 represents approximately 12 mA and 27648 represents 20 mA.

Values outside the nominal range can produce overrange or underrange behaviour. Incorrect parameter assignment can cause the module to output a zero signal. Critical speed, pressure or valve commands should therefore be generated with bounded scaling and a deliberately defined fault response rather than unrestricted constants.

Response to CPU or Master STOP

The module can be configured to de-energise the output, apply a substitute value or retain the last value when the CPU or DP master enters STOP. The correct choice depends on the process. Retaining the last command may be useful in one system but may allow hazardous movement or pressure to continue in another.

Safety-related stopping must not depend solely on a standard analog-output parameter. Where required by the risk assessment, use suitable ET 200 safety modules, PROFIsafe communication and functional modules. The 6ES7135-4MB02-0AB0 is a standard analog output module, not an F-module.

Compatible Terminal Modules

The electronic module is installed on a compatible ET 200S terminal module. The Siemens product manual lists the following alternatives:

Spring terminals:
TM-E15C26-A1 – 6ES7193-4CA50-0AA0
TM-E15C24-A1 – 6ES7193-4CA30-0AA0
TM-E15C24-01 – 6ES7193-4CB30-0AA0
TM-E15C23-01 – 6ES7193-4CB10-0AA0

Screw terminals:
TM-E15S26-A1 – 6ES7193-4CA40-0AA0
TM-E15S24-A1 – 6ES7193-4CA20-0AA0
TM-E15S24-01 – 6ES7193-4CB20-0AA0
TM-E15S23-01 – 6ES7193-4CB00-0AA0

Fast Connect terminals:
TM-E15N26-A1 – 6ES7193-4CA80-0AA0
TM-E15N24-A1 – 6ES7193-4CA70-0AA0
TM-E15N24-01 – 6ES7193-4CB70-0AA0
TM-E15N23-01 – 6ES7193-4CB60-0AA0

Selection must consider the complete article number, terminal technology, AUX contacts and potential-group arrangement rather than width alone. Also verify the associated ET 200 connection modules, ET 200 power supply modules and ET 200 power-distribution modules.

Wiring and Channel Isolation

The current outputs are identified as QI0 and QI1, with MANA as the analog reference. Two-wire current-output connection is supported. Shielded, twisted-pair analog cable should be routed separately from motor and power wiring.

The channels are isolated from the backplane bus and load voltage, but the two output channels are not galvanically isolated from each other. This must be considered when the receiving devices are located in different panels or use different grounding potentials. If grounding the shield at both ends creates equalisation current, appropriate potential bonding or single-ended shield grounding may be necessary.

Diagnostics and Troubleshooting

The red SF LED can indicate an incorrect configuration, missing load voltage, an internal module fault or another active diagnostic message. Wire-break diagnostics can be enabled by channel for a suitable 4–20 mA configuration. Diagnostic support does not guarantee detection of every field fault; the selected range and connected load must satisfy the diagnostic conditions.

Compare the installed article number with the STEP 7 hardware configuration before checking L+, QI-to-MANA wiring, load resistance and the input mode of the receiving device. A basic on/off test used for ET 200 digital output modules does not verify the accuracy of this analog module.

Used-Module Inspection

1. Confirm the complete 6ES7135-4MB02-0AB0 article number.
2. Verify that the device is the 2AO I current version rather than a 2AO U voltage version.
3. Test both channels separately in the 4–20 mA and, where possible, ±20 mA ranges.
4. Compare the 4, 12 and 20 mA points with a suitable test load.
5. Test the SF LED, wire-break diagnostics and CPU STOP response.
6. Inspect the terminal contacts for oxidation, heat damage and deformation.
7. Confirm the complete article number of the terminal module.

For product-code or terminal-module comparison, use the Siemens automation contact page and provide the article numbers of both components.

Editor’s note: The most common mistake with this module is assuming that any analog output can also provide 0–10 V. The 4MB02 is a current-output-only module. The absence of galvanic isolation between its two channels is another detail that can be missed when signals are sent to equipment with different ground potentials. An extinguished SF LED is not a complete used-module test; both channels should be measured under a real load with a calibrated instrument.

Manuals and PDF Documents

The Siemens ET 200 manuals and PDF archive contains further ET 200S system documentation.

Siemens 6ES7135-4MB02-0AB0 2AO I HF product manual
English, 04/2007, A5E01076972-01, 24 pages. Covers terminal assignments, technical data, parameters, diagnostics and analog-value representation.

Siemens ET 200S Distributed I/O System operating instructions
English, 08/2008, A5E00515771-06. Covers ET 200S planning, installation, wiring and commissioning.

Reminder: This information is intended to assist product identification and selection. Before ordering or replacing the module, compare the complete article number, terminal module, signal type and receiving-device input specifications with the applicable manufacturer documentation. For used products, also review the stated operating and test condition.