ET200 Analog and interface Input Modules
Siemens ET 200 Interface Modules and CPUs
Siemens ET 200 interface modules connect distributed I/O stations to a control system over PROFIBUS or PROFINET. CPU versions also run a local user program. For an overview of the family, visit the Siemens ET 200 section or read About Siemens ET 200.
The models below include ET 200S IM151 interfaces, Compact units with built-in digital I/O, standard CPUs and fail-safe CPUs. The IM152-1 at the end of the list belongs to ET 200iSP. Always check the complete order number when identifying a device: similar model names can refer to different memory capacities, interfaces and supported functions.
PROFIBUS DP interface modules
6ES7151-1AA01-0AB0 — IM151-1: Connects an ET 200S station to PROFIBUS DP at up to 12 Mbit/s. It provides 128 bytes each for input and output data and supports up to 63 power, electronic or motor starter modules. The PROFIBUS connection uses a 9-pin D-sub connector.
6ES7151-1AA02-0AB0 — IM151-1 STANDARD: A Standard PROFIBUS DP interface for ET 200S, rated for communication at up to 12 Mbit/s. Input and output address spaces are 128 bytes each. Up to 63 power, electronic or motor starter modules can be connected. The network interface is a 9-pin D-sub connection.
6ES7151-1AA04-0AB0 — IM151-1 STANDARD: Provides 244 bytes of input data and 244 bytes of output data. It supports PROFIBUS DP V0/V1 at up to 12 Mbit/s, with a 9-pin D-sub network connection. The station can contain up to 63 modules within a maximum width of 2 m.
6ES7151-1AB02-0AB0 — IM151-1 FO: Uses an integrated fiber-optic PROFIBUS DP interface. The maximum communication rate is 12 Mbit/s, with 128 bytes each for inputs and outputs. It supports up to 63 power, electronic or motor starter modules.
6ES7151-1AB05-0AB0 — IM151-1 FO STANDARD: A fiber-optic PROFIBUS DP interface with 244-byte input and output address spaces. Communication rates up to 12 Mbit/s are supported. The station can contain up to 63 modules across a maximum width of 2 m. Check the manual for the permitted fiber types and connectors.
6ES7151-1BA01-0AB0 — IM151-1 HIGH FEATURE: A PROFIBUS DP interface with isochronous operation. It supports up to 12 Mbit/s, 244 bytes each for input and output data, and a maximum of 63 modules. The network connection uses a 9-pin D-sub connector.
6ES7151-1BA02-0AB0 — IM151-1 HIGH FEATURE: Supports PROFIBUS DP communication at up to 12 Mbit/s. Separate input and output address spaces provide 244 bytes each. Up to 63 modules can be connected. Isochronous operation is supported, and the PROFIBUS interface uses a 9-pin D-sub connector.
6ES7151-1CA00-0AB0 — IM151-1 BASIC: A Basic PROFIBUS DP interface for stations with up to 12 power, electronic or motor starter modules. It supports communication at up to 12 Mbit/s through a 9-pin D-sub connection. F-modules are not supported.
Compact units with built-in digital I/O
6ES7151-1CA00-1BL0 — IM151-1 COMPACT 32DI: Combines a PROFIBUS DP interface with 32 digital inputs rated at 24 V DC. The typical input delay is 3 ms. Up to 12 additional ET 200S modules can be installed alongside the built-in I/O. F-modules cannot be used.
6ES7151-1CA00-3BL0 — IM151-1 COMPACT 16DI/16DO: Combines PROFIBUS DP communication with 16 digital inputs and 16 digital outputs. Inputs are rated at 24 V DC; outputs are rated at 24 V DC, 0.5 A. The typical input delay is 3 ms. Expansion is possible with up to 12 additional ET 200S modules, excluding F-modules.
PROFINET IO interface modules
6ES7151-3AA00-0AB0 — IM151-3 PN: Connects an ET 200S station to PROFINET IO through an RJ45 connection at up to 100 Mbit/s. It supports up to 63 power, electronic or motor starter modules within a maximum station width of 2 m.
6ES7151-3AA20-0AB0 — IM151-3 PN ST: A Standard PROFINET interface with two RJ45 ports and communication at up to 100 Mbit/s. Up to 63 power, electronic or motor starter modules can be connected across a station width of up to 2 m.
6ES7151-3AA22-0AB0 — IM151-3 PN ST: Provides two RJ45 ports for PROFINET communication at up to 100 Mbit/s. The maximum configuration is 63 power, electronic or motor starter modules within a 2 m station width. When replacing a unit, compare the full order number with the hardware entry in the project.
6ES7151-3BA20-0AB0 — IM151-3 PN HIGH FEATURE: A High Feature PROFINET interface with two RJ45 ports and communication at up to 100 Mbit/s. It supports up to 63 I/O modules across a maximum station width of 2 m. Check the applicable firmware and safety-system requirements before using F-modules.
6ES7151-3BA23-0AB0 — IM151-3 PN HF: Provides 100 Mbit/s PROFINET communication through two RJ45 ports. Up to 63 I/O modules can be connected within a maximum station width of 2 m. Available High Feature functions depend on the device firmware and the hardware support provided by the engineering software.
6ES7151-3BB21-0AB0 — IM151-3 PN FO: Features two fiber-optic PROFINET ports and an integrated two-port switch. It supports up to 63 I/O modules across a maximum station width of 2 m. PROFIsafe modules can be used with a suitable F-system and supported firmware. The catalog description also includes a terminating module.
CPUs and fail-safe CPUs
6ES7151-7AA00-0AB0 — IM151-7 CPU: An ET 200S CPU with 24 KB of work memory for a local user program. Its integrated PROFIBUS DP interface can operate as a DP slave through a 9-pin female D-sub connector. No backup battery is used.
6ES7151-7AA10-0AB0 — IM151-7 CPU: Has 48 KB of work memory and an integrated PROFIBUS DP interface with DP slave functionality. The interface uses a 9-pin female D-sub connector. Program load memory is provided by a SIMATIC Micro Memory Card; no backup battery is required.
6ES7151-7AA13-0AB0 — IM151-7 CPU: Provides 96 KB of work memory. Its PROFIBUS DP interface supports DP slave operation through a 9-pin female D-sub connection. Work memory for program execution and data is separate from the load memory on the MMC. The CPU does not use a backup battery.
6ES7151-7AA20-0AB0 — IM151-7 CPU: Has 96 KB of work memory, an integrated PROFIBUS DP interface and DP slave functionality. The network connection is a 9-pin female D-sub. It uses a SIMATIC Micro Memory Card without a backup battery. Earlier models with the same memory capacity do not necessarily support the same firmware functions.
6ES7151-7FA00-0AB0 — IM151-7 F-CPU: An ET 200S fail-safe CPU with 48 KB of work memory. The integrated PROFIBUS DP interface supports DP slave operation through a 9-pin female D-sub connector. No backup battery is used. For this earlier revision, pay particular attention to the supported F-modules and safety-software versions.
6ES7151-7FA01-0AB0 — IM151-7 F-CPU: A fail-safe CPU with 64 KB of work memory. Its integrated PROFIBUS DP interface provides DP slave functionality through a 9-pin female D-sub connection. No backup battery is required. Include the safety program's requirements when calculating memory usage.
6ES7151-7FA20-0AB0 — IM151-7 F-CPU: Provides 128 KB of work memory for ET 200S control and safety applications. The integrated PROFIBUS DP interface can operate as a DP slave through a 9-pin female D-sub connector. No backup battery is required. Select F-modules, firmware and safety software against the complete CPU order number.
6ES7151-8FB00-0AB0 — IM151-8F PN/DP CPU: A fail-safe CPU with 192 KB of work memory. Its integrated PROFINET interface has three RJ45 ports and supports the IO Controller role. All three ports belong to one PROFINET interface. No backup battery is required, but a SIMATIC Micro Memory Card must be fitted.
ET 200iSP interface module
6ES7152-1AA00-0AB0 — IM152-1: A PROFIBUS DP interface for the ET 200iSP system. It supports standard and redundant operation and uses PROFIBUS RS 485-IS. ET 200iSP has a different station architecture from ET 200S. Select the terminal module, network connection arrangement and Ex installation components according to the ET 200iSP documentation.
Choosing a module or replacement
Start by comparing the complete order number, hardware revision and firmware version on the device with the project configuration. Standard, High Feature, Basic, FO and CPU versions have different capabilities. Use the correct GSD file for PROFIBUS, GSDML file for PROFINET, or supported hardware entry in the engineering software. STEP 7 and TIA Portal compatibility must also be checked for the exact device and software version.
An I/O data area of 128 or 244 bytes is not a CPU memory specification. It describes the input or output data capacity of the interface. The 24, 48, 64, 96, 128 and 192 KB figures listed for the CPUs refer to work memory.
A limit of 63 modules or a 2 m station width is only part of the configuration requirements. Also check module data sizes, power requirements, potential groups and backplane bus limits. Certain module combinations reduce the permitted number of modules. On Compact units, the 12-module limit applies to expansion modules fitted in addition to the built-in digital I/O.
F-CPU or PROFIsafe support still requires a compatibility check for the chosen F-module and firmware. Likewise, battery-free operation refers to the backup battery. The device still needs its external power supply and any memory card specified for that model.
User manuals and PDF documents
Visit Siemens ET 200 user manuals and PDF documents for wiring diagrams, terminal selection, communication settings and detailed specifications. Check that the selected document covers the device's complete order number and hardware revision.
Related topics
For background on controllers and industrial networks, see What is a PLC?, What is PROFIBUS?, What is PROFINET? and ET 200 PROFIBUS and PROFINET interfaces.
Other station components are covered in the ET 200 PROFIsafe, ET 200 terminal blocks and ET 200 special input modules sections. Components from the same family still need to be checked for revision-specific compatibility.
For analog field signals, see 4–20 mA output sensors and 0–10 V output sensors. These signals connect to suitable analog input modules within the ET 200 station.
You can also explore Siemens S7-300, S7-300 CPU modules, S7-300 digital input modules, S7-300 digital output modules and S7-300 analog modules. S7-300 and ET 200S use different mechanical systems; these links do not indicate that their modules are directly interchangeable.
Technical references
Siemens SIMATIC ET 200S system and module manuals; IM151-1 FO STANDARD, HIGH FEATURE and COMPACT manuals; IM151-7 CPU/F-CPU and IM151-8F PN/DP CPU product information; the ET 200iSP IM152-1 data sheet; and the relevant Siemens product records. For PDF and manual access, use the ET 200 manuals page linked above.
Editorial note: This page helps identify the models and their main differences. Suitability for an existing installation must be established from the complete order number, hardware and firmware revision, station configuration and applicable manufacturer documentation.