6ES5 330-7AB11

Siemens SIMATIC S5 6ES5 330-7AB11 Test Module

The Siemens 6ES5 330-7AB11 is the 330 test module for commissioning and troubleshooting programs on the SIMATIC S5-110A. For system context, see the SIMATIC S5 PLC overview and the SIMATIC S5 CPU range.

Test functions and installation

Select a hexadecimal start and end address to run a section of the program. The module displays the memory address and instruction together with the signal state and logic result. Single-step mode lets you follow execution one instruction at a time.

Siemens Figure 12 shows the module clipped into the free mounting position beside the 930 power supply and cabled to the 900 CPU. For testing, the programmed 910 memory submodule plugs into the 330. The S5 cable guide covers other S5 connections. Use Figure 12 for the 330 setup.

The S5-110A parts list includes the standard 710-0SA11 rack and the extended 710-0SA41 rack. It lists the 6ES5 330-7AB11 at approximately 0.52 kg.

The 6ES5 500-7AA12 is the S5-110A programmer interface. The 6ES5 325-0UA11 FOX PG adapter is for the PG730/750. When browsing S5 interface modules, match the full part number to the equipment being connected.

For field signal checks, match the program input address to the S5 digital input module. The S5-110A manual lists the 6ES5 400-7AA13 and the 6ES5 401-7AA13 with group signal as separate input cards.

If a field output differs from the logic result, check the S5 digital output card and the load circuit separately. The Siemens parts list identifies the 6ES5 410-7AA11 as a 24 V DC transistor output card.

The same manual lists the 6ES5 382-0AA32 as an adapter block for the 381 timer/counter. The 6ES5 380-8MA11 and 6ES5 390-5AA22 are separate timing or counting devices. Check the full part number and system fit for the 385A and 385B counters as well.

Editor’s note

Before buying a used unit, verify 6ES5 330-7AB11 on the label and S5-110A on the controller. The 332 test adapter shown in the manual is a separate part.

Ask whether the cable between the 330 and the 900 CPU is included. Request a photo of both ends and check the connector latches.

Isolate power before fitting the unit. Use Figure 12 to identify the spare position next to the 930, the rack clips and the socket for the 910 memory submodule.

Choose a short address range from the program listing. With field outputs safely isolated, verify that the displayed address and instruction advance in single-step mode.

When the displayed signal state or logic result is unexpected, compare the instruction with the program listing at the same hex address. Then check the input signal and output load separately.

Siemens manual and PDF archive

+ S5-110A Operating Instructions · GWA 4NEB 807 0690-02 · English, 39 PDF pages
Section 1.3.10 and Figure 12 cover installation. Printed page 6.1 lists the full order number. The dedicated 330 instructions, GWA 4NEB 807 0518-02a, are a separate document.

+ Other SIMATIC S5 PDF files

Related topics

+ SIMATIC S5 242 counter module

+ SIMATIC S5 analog modules

+ SIMATIC S5 positioning modules

Used Siemens equipment

+ SIMATIC S5 special modules

+ Siemens SIMATIC S5

+ Used Siemens equipment

+ Used automation equipment

If you have a module to sell, email a label photo, the quantity and the known condition to otomasyonavm@gmail.com.