6ES5 247-4UA21
Siemens 6ES5 247-4UA21 IP 247 stepper motor positioning module
The 6ES5 247-4UA21 is an IP 247 module for positioning stepper motor axes in a SIMATIC S5 system. Within the S5 positioning module range, the IP 247 family generates motion commands for three independent axes and sends them to external stepper drives.
Pulse, direction and position
In the IP 247 family, the stepper drive receives pulse and direction signals. The pulse count determines travel in combination with the step resolution and mechanical transmission ratio. Pulse frequency determines axis speed. In open-loop operation, the module calculates position from the pulses it sends. If the motor misses steps, the calculated position can differ from the actual position.
S5-115U installation and power
Table 15-1 of the S5-115U system manual lists the 4UA21 at 0.8 A from the internal 5 V rail and specifies an adapter casing. The same table lists no fan requirement for the 4UA21. Check the permitted S5 rack slots and power supply capacity separately. Siemens excludes the IP 247 from the 3 A power supply configurations shown for the CR 700-2 and CR 700-3.
For certain CR 700-2LB slots, Siemens specifies the 6ES5 491-0LB11 adapter casing. Use the slot diagram for your rack order number. When tracing S5 cables, identify the drive command wiring separately from the PLC’s digital input and digital output circuits. Use the machine’s 4UA21 wiring diagram for pin assignments.
When considering a spare, compare the label, rack, casing and drive connections with the 247-4UA11, 247-4UA31 and 247-4UA41. The IP 267 is a separate stepper motor controller. Before removing the module, back up the STEP 5 project, axis data and any commissioning files used on the machine.
Editor’s note
+ When buying a used module, request photos of the 4UA21 label, the front panel and the adapter casing label. Confirm separately whether the casing and drive cable are included.
+ Before removal, record the slot, axis order, homing direction and pulses per millimetre. Keep separate copies of the original STEP 5 project and axis data.
+ After safely isolating the equipment, inspect the casing and rack contacts. If the card drops out intermittently, rule out loose plugs and damaged card guides before fitting a spare.
+ If the axis receives a command but stays still, check the drive’s ready and enable states, then the limit and reference inputs. Trace the pulse and direction wiring against the machine drawing.
+ If the PLC shows the target reached while the axis falls short, repeat the move at low speed. A proportional error points to pulse scaling. An error that grows with speed or load calls for a check for missed steps and mechanical binding.
+ After replacement, test one axis at low speed under the site commissioning procedure. Verify direction first, then homing repeatability and limit operation.
For a used module, ask whether the axis outputs were tested with a drive. To sell a module, email the full part number, quantity, operating condition, label photo and asking price to otomasyonavm@gmail.com.
PDFs and Siemens references
+ S5-115U system manual, 4UA21 data, Table 15-1 (EN)
+ S5-115U system manual, rack and power supply diagrams (EN)
+ Siemens ST 50, IP 247 family overview, pp. 4/69–4/70 (EN)
+ IP 247 manual covering the 4UA31 and 4UA41 (EN)
Related topics
+ Stepper motor control signals
+ Calculating stepper motor resolution