6ES5 246-4UB21
Siemens SIMATIC S5 6ES5 246-4UB21 – IP 246A absolute positioning module
The 6ES5 246-4UB21 (IP 246A) provides closed-loop positioning for two independent axes. It compares encoder feedback with the target and sends an analogue speed reference to each drive. Within the S5 positioning range, this is the absolute version specified for operation without forced ventilation in the S5-115. The 4UB11 is the absolute version that requires forced ventilation. The 4UA41 and 4UA31 are incremental versions.
Encoder, drive and power connections
Absolute encoders X4 is the 26-pin socket for axis 1 and X5 is the corresponding socket for axis 2. Each axis accepts 24 V parallel Gray or Gray excess-X signals with up to 20 bits. Both encoders must use the same sourcing or sinking output type. Use the pin table in section 3.4 when matching the shielded S5 cables and connectors.
Drive and digital signals X6 provides one ±10 V analogue speed reference per axis. Trace these lines separately from signals on other S5 analogue modules. X7 carries four 24 V digital inputs and two 24 V/120 mA outputs per axis. When checking field digital inputs and digital outputs, include the IP 246 limit, start/stop, position-reached and drive-enable signals.
Power The module draws 5 V from the backplane via the S5 system supply. The front L+ terminal takes a separate 24 V DC load supply. Siemens specifies an L+ range of 20–30 V and a 0–55 °C operating range for the version that requires no fan.
Rack compatibility and COM 246
For the S5-115U CPU family, the hardware manual lists CPUs 941, 942, 943 and 944 and specifies CP slots. If your S5 rack is a CR 700-2 or CR 700-3, confirm the slot arrangement and clearance from the rack drawing. In an expansion unit, check the central-controller bus and fitted S5 interface modules.
COM 246 uses the X8 TTY programming port to read, save and test machine data and traversing programs. In STEP 5, FB164 handles operation and monitoring, while FB165 handles parameter assignment. The Siemens S5 PLC guide and S5 function modules pages help identify the controller and its task-specific cards.
For other axis cards, compare the drive command type, encoder interface and axis count on the IP 247, IP 266 and IP 288 pages with the installed hardware.
Editor’s note
When buying used, ask for photos of the full 4UB21 label, both 26-pin encoder sockets and the EPROM module. Ask for a COM 246 actual-position readout from both axes on the bench.
Before removing the card, back up the traversing programs and both machine data records with a valid reference point. Keep the referenced data in the CPU and in a separate backup.
When replacing an encoder, confirm its Gray code format, steps per turn, turn count and output type. With power isolated, check jumper X17. The manual specifies pins 2–3 for sourcing encoders and pins 1–2 for sinking encoders.
If the PLC reports error 60 or COM 246 shows BC, check the configured total step count, X17, encoder supply and the X4/X5 cable. Record which axis loses its actual-position reading before replacing the card.
If the module accepts a move and the axis remains stationary, trace the drive enable and X6 speed reference separately. Use the schematic to follow the X7 FUM output to the drive enable input.
Isolate the rack, load supply and any external encoder supply before fitting or removing the card. Before enabling motion, check actual position against a known mechanical position and verify counting direction and limits against the machine documentation.
Siemens PDF documents
+ IP 246 / COM 246 manual – 6ES5 998-5SA23 (EN)
+ IP 246 / COM 246 manual – 6ES5 998-5SA13 (DE)
+ SIMATIC S5 shared PDF archive
Related topics
+ IP 246A 6ES5 246-4UB11 version for forced ventilation
+ IP 246I 6ES5 246-4UA41 incremental version