6ES5 307-3UA11
6ES5 307-3UA11 – SIMATIC S5 IM 307 Fiber Optic Expansion Interface
Siemens 6ES5 307-3UA11 is an IM 307 interface module used to establish a fiber optic connection from a central controller to a remote expansion unit. The Siemens S5-135U/155U connection table pairs IM 307 in the central controller with IM 317 in the expansion unit. This S5 interface solution supports distributed placement of Siemens S5 I/O hardware.
Siemens documentation specifies a fiber connection of up to 1500 m using the 6ES5 722-2 cable family. The IM 307/317 manual gives 1 A current consumption from the 5 V rail for 307-3UA11. When selecting equipment for a SIMATIC S5 installation, check the 6ES5 317-3UA11 counterpart, subrack and optical hardware alongside these figures.
Fiber cable and optical hardware
The manual describes the 6ES5 722-2XXX0 duplex fiber cable with 62.5/125 µm fiber and ST connections. When selecting S5 cables and connectors, assess the fiber type, terminations and optical loss together. The 1500 m limit does not establish the same reach with an arbitrary fiber cable.
The 6ES5 307-0MM11 media module is listed as a separate component in the IM 307/317 manual. For a used assembly, check the supplied main board, media module, counterpart interface and fiber terminations individually. Optical transmission does not remove the cabinet and subrack grounding requirements.
Expansion subracks and installation
The S5-135U/155U system table shows IM 307/317 connections for ER 701-2, ER 701-3, EG/EU 183U and EG/EU 185U. ER 701-2 and ER 701-3 additionally require an IM 306. When reviewing IM 306 options, match the complete order number to the documentation for the actual subrack.
Slot selection and the CONF setting affect the available functions. Interrupt transmission and fault behavior cannot be determined solely by whether the module fits a slot. Check the power supply and bus supply budget, and isolate power before changing hardware.
Distinguishing other expansion connections
The IM 304, 304-3UB11 and IM 314, 314-3UA11 form a different interface pair. Likewise, the 308-3UA12 and 318-3UA11 connection is a different arrangement from the IM 307/317 optical link. Check the counterpart interface and cable family together during maintenance.
Other communication interfaces, including 308-3UB11, 308-3UC11 and 308-3UC21, should not be treated as substitutes based on similar codes. Nearby centralized expansion options such as 312-5AA13 also use a different physical and connection arrangement. Identify the existing system diagram first.
Checking a connection fault
If the expansion unit is inaccessible, start with power at both ends, optical transmit/receive direction, clean fiber terminations and cable damage. During troubleshooting, comparison with a suitable known-working optical link can help. Once the hardware is verified, check the slot, CONF and programming/addressing settings.
Editor’s note
With these older S5 systems, look at the whole connection. There is an IM 307 at one end, an IM 317 at the other and suitable optical hardware between them. Check that they belong together before chasing faults in an incomplete setup.
A failed fiber link does not immediately condemn the main board. Dirty terminations, reversed connections or a crushed cable can produce the same complaint. Have the ends checked with the appropriate methods before replacing a healthy board.
Do not buy a random cable on the strength of “it works over 1500 metres.” Fiber type and connector type are part of the specification. Check the cable label and ends first; establish the correct cable before discussing distance.
When buying a used Siemens part, ask whether the media module is included and which counterpart was used for testing. Request photographs of the label, optical section and connectors together. Knowing the test arrangement is more useful than a bare “it works.”
Record the slot number, CONF setting and cable directions before removing anything. A replacement that looks identical may have different settings. Document the existing arrangement first, then work through one change at a time.
OtomasyonAVM resources and PDFs
+ S5 interface and expansion modules.
+ 307-0MM11 fiber optic media module.
+ S5 PDF archive: system and connection resources. The English S5-135U/155U system manual documents the interface pairing; the German IM 307/317 manual covers technical and installation details.
Related topics
+ IM 306 interface options · S5 cables and connectors.
+ 304-3UB11 · 314-3UA11 · 308-3UA12.
+ Troubleshooting PLC expansion connections.
Browse SIMATIC S5
S5 interfaces · S5 cables · SIMATIC S5 · Siemens S5 PLC · Siemens second-hand main page
Siemens and external references
+ Same Siemens manual, section 4.3, printed page 4-4: duplex fiber cable and ST connection details.