6ES5 635-0UA11
Siemens 6ES5 635-0UA11 — PG 635 Programmer, German Version
Siemens 6ES5 635-0UA11 is the German version of the SIMATIC S5 PG 635 programmer. It is used for program preparation, testing and online monitoring of Siemens S5 systems. Siemens system documentation describes the PG 635 as a portable, briefcase-format programmer with a fold-out LCD.
For PLC maintenance, it provides service access to the SIMATIC S5 controller. Check the complete part number when selecting S5 auxiliary equipment: the 6ES5 635-0UA11 programmer and the 6ES5 635-0AA11 CRT interface are separate products. The presence of a display interface does not establish that the programming software or connecting cable is included.
STEP 5 software and program representation
PLC programming requires a compatible STEP 5 software package. S5 documentation describes AWL statement list, KOP ladder diagram and FUP function block diagram representations. For ladder diagrams and function block diagrams, check the installed software version and whether the program can be represented in the selected format.
When checking the programming software, a successful power-up is only the beginning. The operating system, STEP 5 files and any required COM software package must be available together. Software needed for S5 communications modules or specialist function modules should be checked separately from the basic programming package.
Two floppy drives and PCP/M-86 operation
Siemens’ COM 247 manual describes the PG 635 with two floppy drives. Its example uses PCP/M-86 booting from drive A:, followed by ZEFU/S5-DOS and COM 247 disks. Check the disk sequence in the instructions for the software package being used.
Assess a used PG 635 together with its readable system disks and working drives. For Siemens S5 maintenance, keeping copies of original disks, recording project names and preserving a separate archive makes later work easier. Losing a single essential system disk can prevent an otherwise working programmer from being used on site.
PG connection and the 20 mA interface
Select an S5 connecting cable suitable for both devices. Siemens’ IP 247 manual describes a PG 635 connection using a 20 mA interface at 9600 bit/s. These details apply to the documented IP 247 connection; verify other connections separately.
A USB-to-RS232 converter alone does not provide compatibility with a 20 mA current loop. For S5 interfaces, the electrical levels, cable wiring and target equipment requirements must all match. Connector fit is insufficient; verify the wiring against the relevant equipment documentation.
Program backup, addressing and diagnostics
Before fault-finding, record the CPU identification, existing program and connection arrangement. Initial access should prioritise reading, inspecting the block directory and recording the current state. Before making changes, compare the blocks read from the CPU with the available project archive and establish that both belong to the same machine.
RAM contents, an S5 memory module and an EPROM are different storage locations. Preserve project files, comments and symbols separately. Input, output, flag and data addresses viewed through the programmer belong to the connected CPU’s address space; the PG 635 does not have one universal PLC I/O address table.
Related programmers and used-unit checks
The 6ES5 675-0UA11 PG 675 and 6ES5 685-0UA11 PG 685 are other S5 programmers worth comparing. Select a replacement by checking the software version, data transfer method, connecting cable and target CPU together. A shared STEP 5 background does not establish that existing disks or accessories can be used directly.
A useful acceptance check covers the complete identification label, supply rating, LCD readability, keyboard, both floppy drives and an actual online connection. Follow the unit’s supply label, and avoid transferring memory, display or electrical ratings from another PG model. Confirm separately which software and cables are included.
Editor’s note
Start with photographs of the identification label, system disks and connecting cables together. On a programmer of this age, a missing disk or incorrect cable can matter as much as a hardware fault. A successful power-up does not complete the assessment.
Never use the only copy of a machine program as a drive-test disk. Preserve a backup first, then test reading and writing with a suitable expendable disk. A working drive A: does not establish that drive B: is also serviceable.
Check the LCD and keyboard beyond the startup screen. Open the program editor and try the required keys. Read the display at different angles and look for missing characters or interruptions as the lid moves.
Do not rush into downloading a program after connecting to the CPU. Preserve the existing blocks and the machine’s project archive first. A machine name written on a disk label does not establish that its contents are current.
Complete the assessment with actual communication to a known-good S5 CPU. Start the software, read the block directory and repeat the connection test after warm-up. Testing the programmer, software and cable together gives a more useful result for field service.
OtomasyonAVM resources and PDFs
See About Siemens S5 PLC, S5 cable types and the PG 635 CRT interface page first. General system documents are collected in the Siemens S5 PDF archive. The manufacturer references below document PG 635 applications; they are not presented as a dedicated service manual for this exact part number.
Related topics
+ 6ES5 675-0UA11 — PG 675 programmer.
+ 6ES5 685-0UA11 — PG 685 programmer.
+ 6ES5 635-0AA11 — PG 635 CRT interface.
+ S5 memory modules · S5 interface modules.
Browse SIMATIC S5
S5 auxiliary and expansion equipment · SIMATIC S5 · Siemens S5 PLC · Used Siemens equipment
Siemens and external references
Siemens S5-115U — CPU 941/942/943/944 Gerätehandbuch, Ausgabe 03 — Portable LCD design of the PG 635, programmer applications and STEP 5 representations; sections 1.5, 2.3.3 and 6.1.
Siemens IP 247 — Manual, Release 02, 6ES5 998-5SB22 — Connection: section 3.3.5, PDF p. 89. Drives and startup: PDF pp. 144–145.
Siemens S5-100U — CPU 100/102/103, GWA 4NEB 812 6011-09b — The ordering list on printed p. 2-6 of this Russian-language manufacturer document identifies 6ES5 635-0UA11 as a PG 635 programmer. Check the software and accessory contents of a used unit separately.