6ES5 375-0LD11
6ES5 375-0LD11 Siemens SIMATIC S5 375 RAM Memory Submodule, 8 KB
The Siemens 6ES5 375-0LD11 is a plug-in SIMATIC S5 375 RAM submodule with 8 KB of memory (8,192 bytes, 8K × 8 bits). It expands program memory on the SIMATIC S5-115U CPU 941 and CPU 942. It is also one of the S5 memory cards listed for test mode on the S5-115F CPU 942F.
The card holds STEP 5 program blocks in working memory. On a CPU 941 or 942, the program can be transferred through the CPU’s PG port using a PG connection cable. Keep a separate copy of the running program on the PG because the card uses volatile RAM.
Which CPUs and communications processors support it?
On an S5-115U CPU 941 or CPU 942, the card adds 8 KB to the internal program memory. The CPU 943 and CPU 944 run the program from their internal RAM. Check the full CPU order number before selecting a RAM expansion card.
The S5-115H manual lists the 0LD11 for the two-CPU system with CPU 942H. The memory submodules in both CPUs must have the same full order number. On the S5-115F CPU 942F, RAM is reserved for test mode. For safety mode, use the program memory specified in the system manual.
Among the S5 communications processors, the CP 521 BASIC supports the 0LD11 as a 1 × 8 KB RAM submodule for BASIC programs or startup parameters. The SINEC L2 CP 5430 manual lists the same part for parameter data.
What keeps the program in memory when power is off?
The card retains its contents during a power outage through the host device’s battery backup. On the S5-115U, check the battery status at the power supply. If the system uses a PS 951 power supply, check both supply and battery status. The CP 521 BASIC has its own backup battery.
If the program disappears after a power cycle, check the labels on the CPU and power supply fitted to the S5 rack. On the CP 521 BASIC, the yellow BATTERY OFF/LOW indicator signals a missing or weak battery.
How does the 0LD11 differ from other 375 memory cards?
The 0LD11 RAM and 6ES5 375-0LC31 EEPROM both hold 8 KB. The 0LC31 is nonvolatile and retains data without power. The 6ES5 375-1LA15 EPROM requires a separate programming step. Check the memory type as well as the capacity and housing when selecting a spare.
The 6ES5 375-0LD21 and 6ES5 375-0LD31 are the 16 KB and 32 KB versions in the same RAM family. Check the capacity, CPU or CP model, and supported memory order numbers in the applicable manual.
Editor’s note
Read the 375-0LD11 suffix on the label. When several SIMATIC S5 parts are on the bench, record the memory card and CPU order numbers separately.
In a cabinet with a CR 700-2 mounting rack, use the installed CPU’s label and manual to check memory compatibility. The rack number identifies the mounting assembly.
On a CPU 941 or 942, an overall reset also clears the installed RAM card. Take a readable PG backup first. If the PG connection drops out, check the S5 programming cable and PG interface before proceeding.
Record the memory card labels from both CPUs on an S5-115H. After replacing RAM, follow the S5-115H system manual for program and synchronization checks.
The CP 521 SI manual lists EPROM and EEPROM for its memory socket. The CP 521 printer processor is a separate model as well. Check for BASIC on the label and leave the submodule in place while the CPU is in RUN.
OtomasyonAVM resources and PDFs
SIMATIC S5 memory cards · S5-90U and S5-115U CPU pages
SIMATIC S5-115 PDF archive · SIMATIC S5-115H system manual (English PDF)
Related topics
6ES5 375-0LC31 EEPROM · S5-115H CPU 942H · CP 521 BASIC
S5 navigation
External references
Siemens S5-115U system manual, Table 2-8 and Chapter 4 · Siemens S5-115F system manual, Volume 1, Table 2-4
Siemens CP 521 BASIC manual, Table 2-2 and Section 2.7 · Siemens SINEC L2 CP 5430 manual, Table 2.6 (German)