6ES5 581-1LA11

Siemens 6ES5 581-1LA11 – CP 581 Mass Storage Module with 120 MB Hard Disk

Siemens 6ES5 581-1LA11 is a 120 MB mass storage module for the CP 581 / CP 581/486 system. It combines a 2.5-inch IDE hard disk and a 3.5-inch floppy disk drive on one board. It serves the CP 581 computer arrangement in Siemens S5 PLC installations and must be distinguished from the basic processor board among S5 communication and processor equipment.

The disk stores the operating system, CP 581 system software and application files. 120 MB is hard disk capacity, not working RAM. This module does not replace a PLC CPU or an S5 memory module. When documenting the Siemens S5 system, keep separate records for the CPU program, CP application and disk backup.

Relationship with the CP 581 basic board

CP 581 basic boards such as 6ES5 581-0EA11 and 6ES5 581-1EA11, and CP 581/486 basic boards such as 6ES5 581-0EB11 and 6ES5 581-1EB11, perform a different role from the storage module. The Siemens manual also lists 581-1LA11 as the 120 MB storage component for CP 581/486. Record the installed basic board's complete order number and hardware version before ordering.

The storage module connects to the basic board through a 128-way internal ISA connector and is secured with the manufacturer's assembly hardware. When reviewing the S5 CPU family and S5 additional equipment, assess the rack, basic board, adjacent modules and power budget together.

Hard disk and floppy drive

The Siemens technical table for this version specifies a Conner CP2124, 2.5-inch, 120 MB IDE hard disk. A used unit may have a replacement drive, so inspect the board label and drive label separately. Logical drive size and available free space depend on partitioning and installed files.

The floppy drive supports 3.5-inch 1.44 MB HD and 720 KB DD media. Do not remove a floppy disk while its access indicator is illuminated. Successful floppy operation does not establish hard disk health; test the two drives independently.

LPT and COM 4 connections

The front panel provides a 25-way LPT/Centronics connection and a 26-way high-density COM 4 connection. V.24 and TTY interfaces are documented for COM 4. When selecting S5 cables and connectors or S5 interface equipment, check signal type and manufacturer pin assignments alongside connector shape.

The manual identifies LPT for a parallel printer or a suitable software protection dongle. COM 4 enablement and active/passive TTY operation depend on switch and jumper settings. Document existing settings before changing them; this description is not a substitute for a wiring diagram.

Power supply and mechanical data

Specified supplies are +5 V DC, ±5% and +24 V DC, +25%/−15%. Consumption on the +5 V rail is typically 0.5 A, rising to 1 A maximum for approximately 500 ms during restart. The +24 V rail is rated at 0.1 A maximum. These are the module's supply requirements within the system.

The board uses a 160 × 233.4 mm double Eurocard format, with a 20 mm front panel and an approximate weight of 0.9 kg. The storage module occupies one S5 slot; the basic board and other components add to the complete assembly width.

Distinction from RAM, AT-slot modules and other disk versions

The 6ES5 581-0HA11 RAM expansion, 6ES5 581-0RA11 AT-slot module and 6ES5 581-0RA12 AT-slot module serve different purposes. Increasing hard disk capacity does not increase RAM, and adding an AT-card slot does not provide a disk backup.

6ES5 581-3LA11, 6ES5 581-4LA11 and 6ES5 581-6LA11 are different storage order numbers. A higher-capacity version must not be treated as an unconditional replacement for 581-1LA11. Check drive recognition, basic board, BIOS/SETUP and software requirements together. Do not assume that PLC programming files and the CP 581 operating system and application files are covered by the same backup.

Editor's note

The machine-specific files inside this module can be more valuable than the hardware. If the system still works, obtain the most complete backup possible first. Copying the visible application folder alone may omit boot information, drivers and configuration needed for recovery.

If the disk clicks, repeatedly stalls or intermittently loses files, avoid repeated power cycling. Stop experiments that stress the drive when the data matters. PLC troubleshooting and disk recovery require different approaches; establish which component is failing before proceeding.

Test the floppy drive with known-good, expendable test media. Do not use the machine's only backup disk for this purpose. Check reading, writing and subsequent reading separately; an illuminated drive LED does not prove that an operation succeeded.

Take spacers and screws seriously. A misaligned internal connector or an excessively long screw can damage a working board. Photograph the arrangement before removal, disconnect system power and observe ESD precautions during handling.

For a used purchase, document the complete board number, installed drive model, boot test, readability and supplied backups. Among used Siemens equipment, “disk included” does not establish that the operating system and machine application are complete.

When considering a replacement disk or adapter, capacity alone is insufficient. The old system's drive recognition, partitioning and boot compatibility also matter. Document the existing arrangement, preserve the original disk and verify changes on a copy.

OtomasyonAVM resources and PDFs

Start with About Siemens S5 PLC, S5 additional equipment and S5 communication modules.

+ S5-115U PDF files: related PLC and system documentation. For the CP 581 storage module's detailed requirements, use the CP 581 hardware manual listed below.

Related topics

+ 6ES5 581-1EA11: CP 581 basic board.

+ 6ES5 581-1EB11: CP 581/486 basic board.

+ 6ES5 581-0RA12: AT-slot module, a different component from the storage module.

+ 6ES5 581-4LA11: another disk version; replacement requirements need separate verification.

Browse related equipment

Siemens S5 PLC · S5 additional equipment · S5 memory modules · Cables and connectors · Communication modules · Used Siemens equipment

Siemens and external references

+ Siemens CP 581 Manual, Volume 1 – Hardware, 6ES5 998-2AT21: third-party archive copy of the manufacturer's manual. Section 3.2, printed pages 3-41–3-52, covers connections and drives; section 4.2, printed pages 4-10–4-13, covers electrical and mechanical data. PDF pages 145 and 227 confirm the 120 MB capacity of 581-1LA11.