6ES5 943-7UB11
Siemens 6ES5 943-7UB11 — S5-115U CPU 943, 48 Kbytes RAM, single port
Siemens 6ES5 943-7UB11 is a CPU 943 central processing unit for SIMATIC S5-115U, specified with 48 Kbytes of internal RAM and one serial programmer interface. This CPU in the Siemens S5 family executes the machine program and manages peripheral modules through the S5 bus.
Machine sensor and control signals are handled by separate digital input and digital output modules. Program memory and addressing capacity do not indicate physical I/O terminals on the CPU. Check the complete 7UB11 part number and single-port arrangement when selecting a spare.
48 Kbytes of RAM and 375 memory submodules
Internal RAM is the program’s working memory. Siemens explains that the contents of an installed memory submodule are copied into internal RAM after power-up and overall reset. Retaining RAM during a power failure depends on the system’s battery and backup arrangement.
CPU 943 uses 375-series EPROM/EEPROM submodules. Catalogued EEPROM options include 6ES5 375-0LC31 — 8 Kbytes and 6ES5 375-0LC41 — 16 Kbytes. They do not add working memory to the internal 48 Kbytes. Verify separately that the selected submodule can hold the complete program.
Single TTY port and programmer connection
The integral serial interface on 6ES5 943-7UB11 uses a 20 mA TTY current loop. Select the correct S5 cable and converter for a PG, OP or suitable SINEC L1 connection. A connector that physically fits does not establish electrical compatibility.
7UB11 is the single-interface version. Do not transfer the second-interface and clock features of 6ES5 943-7UB21 to this model. A generic photograph of a two-port CPU 943 does not establish that the item offered is a 7UB11.
STEP 5, instruction timing and internal resources
Programming uses STEP 5. The exact-code specification gives approximately 0.8 µs per bit operation. This is an individual instruction time, not the complete application scan time when selecting an S5-115U CPU.
The processor provides 128 timers, 128 counters and 2048 flag bits. The specified timer range is 0.01–9990 seconds, with a counter range of 0–999. Retentive-area selection and the backup battery affect behaviour following a power interruption.
Rack installation, supply and consumption
The CPU operates in a suitable S5-115U central rack; CR 700-3 / 6ES5 700-3LA12 is one rack option for the system. The manual’s exact 6ES5 943-7UB11 specification gives approximately 0.8 kg. Assess power supply and cooling requirements with all installed modules included.
Power is provided through the system’s PS 951 supply. The exact-code table gives typically 0.2 A from the internal 5 V rail; consumption from the 24 V rail is 0.04 A without a PG and 0.06 A with a PG. Typical power dissipation is 2 W, or 2.5 W with a PG. These are system-rail consumption figures; external supply wiring must follow the system diagram.
Diagnostics and differences between CPU codes
During fault-finding, assess RUN/STOP together with QVZ, ZYK and BASP indications. For S5 maintenance, examine the ISTACK interrupt stack, program state, battery warning and peripheral connections before proceeding directly to CPU replacement.
6ES5 944-7UB11 and 6ES5 943-7UA11 are different order numbers. Compare memory, instruction capabilities, operating system and port arrangement before treating them as direct substitutes. Base spare selection on the complete label, hardware revision and installed program requirements.
Editor’s note
When buying used Siemens equipment, check the 7UB11 label and single front port together. If the listing shows a two-port CPU, obtain photographs of the actual unit before selecting the spare.
Back up the program and data blocks before removal, and record any battery warning. Confirm that the fitted EEPROM contains the current working program before a power-interruption test.
Check the 375 submodule’s complete part number, capacity and pin condition. An 8 or 16 Kbyte EEPROM cannot be assumed to hold every application using the CPU’s 48 Kbyte RAM.
For a failed PG connection, examine the TTY converter, cable and port contacts first. Do not try an RS-232 cable merely because the plug fits.
Under suitable test conditions, verify I/O behaviour, communications and retentive data after power restoration. A RUN indication alone is insufficient; record the tested program version as well.
OtomasyonAVM resources and PDFs
Browse the 6ES5 943-7UB11 model page, SIMATIC S5 CPU family and used Siemens equipment. General documents are collected in the shared Siemens S5 PDF archive. The English system manual covering this exact model and the Siemens catalogue are linked below.
Related topics
+ 6ES5 943-7UB21 — CPU 943 with two serial interfaces.
+ 6ES5 944-7UB11 — CPU 944 with different processor and memory specifications.
+ 6ES5 943-7UA11 — another CPU 943 order version.
+ 6ES5 375-0LC31 — 8 Kbyte EEPROM submodule.
+ 6ES5 375-0LC41 — 16 Kbyte EEPROM submodule.