6ES5 942-7UB11

Siemens 6ES5 942-7UB11 – S5-115U CPU 942B, 10 KB RAM

Siemens 6ES5 942-7UB11 is a CPU 942B central processing unit for SIMATIC S5-115U, with 10 KB of internal RAM and one programmer port. This B-series CPU in the Siemens S5 PLC family executes the user program, evaluates input states and sends commands to output modules.

Typical duties include machine sequencing, interlocks and time-controlled automation. User programs are developed in STEP 5. For PLC programming and servicing, check the full order number, hardware version and installed memory type together.

Internal memory and 42 KB total capacity

Siemens specifies 10 KB of internal RAM and up to 42 KB total program memory with a suitable memory submodule. The detailed table lists 5120 and 21504 STEP 5 statements respectively; its footnote explains that a statement usually occupies two bytes. The 42 KB figure is not the bare CPU's internal RAM capacity.

Suitable 375-series memory submodules include options up to 32 KB RAM or EPROM and 16 KB EEPROM. These are alternatives fitted into the same receptacle; their capacities must not be added together. When selecting additional modules, verify the actual memory type, capacity and program requirements.

Execution from the memory submodule and backup

CPU 941/942 executes the submodule's program from the memory submodule. The manual distinguishes this from processors such as CPU 944B, which load the program from the submodule into internal RAM. Do not automatically apply another CPU's startup or memory-replacement procedure to the 942B.

Internal RAM and any RAM submodule require suitable battery or backup support to retain their contents through a power interruption. Assess the EPROM/EEPROM program separately from variable data held in RAM. Verify that the installed submodule actually matches the current machine program.

Execution times, timers and counters

The exact-order-number specification lists approximately 1.6 µs per binary operation and 1.6–200 µs per word operation, depending on the instruction. The 500 ms default scan-monitoring time can be modified; it is not the actual program scan time.

The CPU provides 128 timers and 128 software counters. The timer range is 0.01–9990 seconds, and the counter range is 0–999. These are not physical high-speed counter inputs. Check retentivity settings and battery backup against the application's required restart behaviour.

Programmer connection and I/O arrangement

The front panel has one serial PG connection. Use an appropriate S5 programming cable for the TTY current-loop interface. Assess interface modules and communication processors separately for the installation's external device connections.

Digital inputs, digital outputs and analog I/O use separate modules. CPU program-memory capacity alone does not determine field channel capacity or signal voltage. Compare I/O addresses, installed modules and project records together.

Supply consumption and mechanical checks

Siemens lists 0.16 A from the rack's 5 V supply and 0.04 A from 24 V without a programmer, or 0.06 A with one connected. Typical power loss is 2 W, increasing to 2.5 W with the programmer; approximate weight is 0.8 kg.

Include both supply rails and the other modules when assessing the PLC power supply. Check rack connectors, locking parts, ventilation and grounding. These consumption figures are not instructions for connecting an arbitrary external supply directly to the CPU.

Differences from related CPUs

6ES5 941-7UB11 is a B-series CPU with a different memory capacity. 6ES5 942-7UA11 belongs to the earlier A series. 6ES5 943-7UB11 and CPU 944B differ in memory architecture and processing performance. Fitting into the same rack does not establish program and hardware compatibility. See About Siemens S5 PLC for family context.

Editor's note

Read the complete 942-7UB11 label first. The 942A, 942B and 942F are different devices; do not select a spare from a listing that merely says “942.”

If a listing advertises 42 KB, request a photograph of the fitted memory submodule. The bare CPU has 10 KB of internal RAM, so establish which submodule supplies the additional capacity.

Do not assume that removing the submodule leaves its program running from RAM. Account for CPU 942's memory architecture and back up the user program, data blocks and submodule contents before making changes.

A battery problem can affect more than the program. Counters, settings and production data may be held in RAM; preserve them before carrying out a power-interruption test.

During fault finding, evaluate QVZ, ZYK and BASP indications together with ISTACK. An unresponsive I/O module or excessive scan time can also take a healthy CPU into STOP.

When buying used Siemens equipment, request PG communication, program reading and operation with the actual memory submodule. Disconnect rack power before removing or inserting hardware. Running an empty program does not establish that the existing machine application works.

OtomasyonAVM resources and PDFs

Browse the 6ES5 942-7UB11 model record, S5 CPU family, memory modules and used Siemens equipment. Check document titles and system coverage in the S5-115 PDF archive. The manufacturer manual containing the exact 7UB11 specification is linked separately below.

Related topics and models

+ 6ES5 941-7UB11: a B-series CPU with a different memory capacity.

+ 6ES5 942-7UA11: A-series CPU 942; check version and consumption data separately.

+ 6ES5 943-7UB11: CPU 943B with different memory architecture and performance.

+ 6ES5 944-7UB11: CPU 944B, which loads the submodule's program into internal RAM.

Other S5 equipment

Siemens S5 PLC · CPUs · Memory · Cables · Interfaces · Racks · Used Siemens equipment

Manufacturer document and external reference

+ Siemens S5-115U Programmable Controller Manual – 6ES5 998-0UF23, English: printed page 15-15 / PDF page 543 contains the exact 6ES5 942-7UB11 specification; section 2.4 compares memory capacities, and Figure 2-9 distinguishes CPU 941/942 submodule execution from CPU 943/944 operation. Document code: EWA 4NEB 811 6130-02b.