6ES5 526-3LA22

Siemens 6ES5 526-3LA22 SIMATIC S5 CP 526 Color Graphics Expansion Board

The Siemens 6ES5 526-3LA22 is a color graphics and memory expansion board for the CP 526. It works with a forced-cooled color CP 526 basic board in S5-115U, S5-135U, S5-150U and S5-155U configurations. It supports a memory submodule of up to 256 kB. Siemens specifies +5 V DC ±5% at 2.3 A and a 640 × 396 pixel, 60 Hz color CRT display.

In a SIMATIC S5 system, the 3LA22 extends the display functions of the color CP 526 basic board. It can plot process values as curves or bars, enlarge text and value fields, and change colors when limits are exceeded. The CPU’s data handling blocks pass process values to the CP. During a test, check that the screen opens and that the displayed values update.

How does it differ from the 3LA21 and the basic boards?

Siemens lists a maximum memory submodule capacity of 128 kB for the 526-3LA21 and 256 kB for the 526-3LA22. The expansion board itself has 8 kB of working RAM. Read the installed memory submodule’s full order number to identify its capacity.

The 526-3LA01 and 526-3LB01 are monochrome basic boards. Siemens specifies a forced-cooled color basic board for the expansion arrangement covered here. If the label identifies a different board, such as the CP 526-2 3LF11 or 526-3LG11, check its own hardware and documentation.

Connection to the basic board and rack layout

A 64-pin ribbon cable connects the expansion board to the basic board, and the two boards are fastened together. The expansion board receives +5 V from the backplane. For S5-115U, check the CR 700-2 and ER 701-3 rack entries and the basic and expansion positions in the CR 700-3 in Siemens Table 4-1.

The same table gives different slot arrangements for the S5-135U, S5-150U and S5-155U. Record the full S5 rack order number and the basic board position before installation. Apply the adapter and backplane jumper requirements for the installed rack.

Color display and memory checks

The color CRT horizontal scan frequency is 30.84 kHz. The monitor cable connects to the CP 526 basic board. In Siemens’ basic board drawing, X17 selects separate sync or sync on green. Check what the monitor expects and verify the other interface connections against the installed equipment.

The expansion board can use an EPROM or RAM submodule for application data. Siemens states that an installed RAM submodule is battery-backed through the backplane. Removing the RAM submodule or the CP 526 causes loss of the application data held in RAM. Make a usable project backup before removal.

Editor’s note

Photograph all three labels together. Record the full numbers of the basic board, 3LA22 expansion board and memory submodule. When buying a spare, ask whether the 64-pin ribbon cable and mounting parts are included.

Check the display path first if there is no picture. Have maintenance staff check the color basic board, monitor cable, monitor sync requirements and airflow against the installed setup.

Check data transfer if the screen opens but values stay fixed. Verify start-up synchronization and data jobs between the Siemens S5 PLC and the CP. The manual includes a separate application example for the S5-135U CPU 928.

Verify the COM GRAPH project before removal. Check that the backup opens and record the RAM or EPROM type. Siemens’ installation instructions call for rack power to be switched off before either board is inserted or removed.

Ask for a live display test when buying used. The test record should identify the basic board, screen and memory submodule, and show at least one curve or bar display updating. Use the S5 maintenance guide alongside the CP 526 manual.

OtomasyonAVM resources and PDFs

CP 526 3LA11 color basic board · CP 526 3LA21 expansion board · SIMATIC S5 hardware overview and manuals

OtomasyonAVM S5 PDF archive

Related topics

CR 700-2 central rack · CR 700-3 central rack · S5 memory submodules

S5 navigation

Siemens S5 PLC · SIMATIC S5 · S5 communications modules · S5 racks

External references

Siemens COROS CP 526 manual, 3LA22 memory and display specifications, page 4-6 (English PDF)

Siemens CP 526 expansion board, application, memory and installation, Chapter 4 (English PDF)

Siemens CP 526 basic board X17 sync selection, section 3.8.4.7 (English PDF)