Siemens 6ES5 247-4UA31 IP 247 Stepper Motor Positioning Module

The 6ES5 247-4UA31 is an IP 247 module for positioning three independent stepper axes in SIMATIC S5. Within the S5 positioning range, this is the 20 mm, single-slot version for forced ventilation. This S5 function module commands the motor power stages and calculates axis position from the steps it generates.

Drive interfaces and field signals

X4, X5 and X6 are the three axis connectors. Each provides pulse, direction and reset signals and receives the drive’s READY signal. The documented drive options include 5 V RS-422 differential and 5 V/20 mA or 24 V/20 mA optocoupler interfaces. Siemens specifies step frequencies up to 100 kHz. Match the drive cable and jumper configuration to the power stage input type.

X7 provides four 24 V digital inputs and one position-reached output per axis. Trace the reference, limit and external start/stop circuits on the machine drawing. Check the 5 V backplane logic feed separately from the 24 V field supply.

Rack, addressing and COM 247

Siemens documents FB164 and FB165 packages for IP 247 on S5-115U, S5-135U, S5-150U and S5-155U. ST 50 lists CPU-specific block data for the CPU 945, CPU 928 and CPU 948. Install the module in an approved CP slot in an actively ventilated S5 rack. Check the installed fan assembly label and airflow against the maintenance record.

COM 247 is used for machine data, traversing programs and online testing. The module’s PG interface is X8. The Siemens cable table lists 6ES5 734-2BF00 for PG 720/740. FB164 operates and monitors the axes, and FB165 transfers data and parameters. S2 sets the base page number. Each axis uses one page, and the fourth page transfers traversing programs.

The manual identifies 4UA41 as the 40 mm, double-width IP 247 with its own heat sink. The 4UA11 and 4UA21 have separate order numbers. Related modules serve different functions. The IP 246I handles positioning with incremental feedback, the IP 265 handles high-speed subcontrol, the IP 266 handles positioning and the IP 267 handles stepper control. Match the full part number, rack and project when choosing a spare.

Editor’s note

Confirm cooling and slot conditions first. Check that the rack fan runs and airflow around the 4UA31 is clear. Follow the plant isolation procedure for the PLC or expansion unit before removal.

Identify the connector for an axis that will not move. Match X4, X5 and X6 to the machine axes. Trace the relevant drive READY return and external stop condition on the drawing.

Compare signal levels when replacing a drive. Verify the old and new pulse input types from their documentation. Record jumper positions and cable labels before making changes.

Check S2 and the FB package if CPU communication fails. Photograph the original S2 setting. Compare the four-page address group with the PLC project and the FB164/FB165 version with the CPU order number.

Back up traversing programs and machine data. After replacement, verify the reference point and physical axis movement in a controlled test. Check for a difference between calculated position and actual travel.

Ask for test results by axis when buying used. Find out which X4, X5 or X6 channel was tested with a drive, whether READY was returned and what ventilated rack was used.

To offer an IP 247 for sale, send the full part number, photos of the front connectors and the test status to otomasyonavm@gmail.com.

PDF and wiring diagrams

+ Siemens IP 247 manual (English PDF) · Front panel Figure 3/2, technical data Section 3.1.4 and addressing Section 3.3.2.

+ Shared S5 PDF archive

Related topics

+ S5 Interface Modules

+ About Siemens S5 PLC

Navigation

+ S5 Positioning Modules

+ SIMATIC S5

+ Second-hand Siemens