GD300-01
INVT Goodrive GD300-01 air compressor drive
INVT GD300-01 is a dedicated variable frequency drive that runs the main motor of an air compressor in response to air demand. In INVT’s rotary screw compressor application, the drive uses pressure and temperature readings to coordinate the main motor, loading valve and cooling fan.
Model code, power and motor selection
In GD300-01-022G-4, 022 identifies the 22 kW rating, G denotes a constant-torque load, and -4 denotes the three-phase 380–440 V input class. The V2.1 manual specifies this class as 380 V (−15%) to 440 V (+10%). Its -4 model table covers 7.5–315 kW and gives a rated output current of 45 A for the 022G-4. When selecting a replacement, check the drive selection criteria alongside the motor’s rated current and rated frequency. For vector control and motor auto-tuning, follow the commissioning conditions specified for the compressor and motor.
Pressure feedback, loading valve and fan
The pressure transmitter converts line pressure into an analogue signal. The guides to measuring compressor pressure and PID feedback explain where to start when the panel and pressure gauge show different values. In VFD PID control, the drive compares measured pressure with the target. Motor speed is the control output of this closed loop.
In V2.1, P18.04 sets the pressure sensor range, P18.05 sets unloading pressure, P18.06 sets loading pressure, and P18.07 sets the target pressure. Match the sensor range to the panel scaling. Use the cabinet schematic to check the PT100 input and the valve and fan arrangement. The guides to compressor controls, frequency reference and acceleration and deceleration ramps explain how these functions fit together.
Operator panel, software and fault records
Appendix A of the GD300-01 manual gives the data addresses for Modbus RTU over RS485. When replacing a panel, keep its exact model number with the project backup. See INVT HMI for the panel family and INVT VFD Software for INVT Studio. Before using Studio’s GD300 family support, confirm compatibility with the -01 variant, its firmware and the installed port.
In V2.1, P07.27–P07.32 show current and previous fault types. The following parameters include the frequency, output current, DC bus voltage and temperature recorded when a fault occurred. The guides to current limiting, the DC bus and switching frequency explain terms used in the records. See INVT Fault Codes for the brand’s fault indexes.
Editor’s Note
If the compressor keeps loading and unloading, compare the panel reading with the gauge on the same line first.
If they disagree, note the range on the transmitter label and the unit selected on the panel before touching the PID settings.
For a temperature alarm, start by asking which temperature rose. Compressor discharge temperature and drive temperature are separate readings. Record the fan status if it’s available.
When buying a spare drive, ask for a clear photo of the full nameplate. If your machine uses a PP100 auxiliary power module, note its code as well.
Keep the drive parameters and panel project together. Have both backups handy before a factory reset.
INVT documents and related series
Start with INVT VFD Documents on OtomasyonAVM. The direct links below open the V2.1 model table, pressure settings, fault records and communications appendix. Use the application manuals for the standard GD300 and GD300-02. The GD300-01A compressor variant has its own documentation. Use the full suffix on the nameplate to select the manual.
INVT category path
INVT brand home › INVT user manuals › Legacy INVT VFD drives › GD300-01
External references
GD300-01 operation manual V2.1 (English PDF)
Model and current ratings · P18 pressure settings · P07 fault history · RS485 and Modbus RTU
GD300-01 operation manual V2.0 (English PDF, earlier edition) · INVT GD300-01 compressor application · INVT GD300-01A manufacturer page