GD200-13
INVT GD200-13 Variable-Frequency Drive
The INVT GD200-13 is an older, protection-enhanced variable-frequency drive range for induction motors using V/f control. The INVT/WEM selection table lists this sub-range at 75–200 kW in the three-phase 400 V class. It specifies wall mounting, fan cooling, an IP20 enclosure and a built-in C3 EMC filter. The protective coating, corrosion-resistant metal parts and air duct design are relevant when assessing the cabinet environment. The table gives ceramics, textile printing and dyeing, chemical processing and water treatment as application examples.
Start with the nameplate
For a replacement, record the -13 suffix, supply voltage, drive output current and motor nameplate current. Base drive selection on the starting torque and duty cycle as well. Check the rated motor frequency, operating speed range and the machine’s speed limit separately. When choosing the enclosure and ventilation, consider the IP and EMC ratings, ambient conditions and drive losses together.
The selection table specifies V/f control for induction motors. If the load needs high torque at low speed, review the open-loop and closed-loop options and the choice of speed or torque control at the design stage. The constant-torque region, current limiting and low-frequency vibration are worth reviewing when replacing an older drive.
Commands, braking and fault records
Record the run command source and frequency reference separately. For example, the panel terminals may provide the run signal while the PLC provides the speed demand. Assess acceleration and deceleration ramps against the load inertia. The S-curve and skip frequency guides describe settings to look for when the machine jolts or vibrates. Verify which settings the drive revision supports.
During deceleration, an inertial load can return regenerative energy and raise the DC bus voltage. If resistor braking is required, check the external braking unit and resistor selection against the exact model documentation. For a trip, record the first code, motor current and whether it occurred during start, run or stop. The VFD fault terminology, PWM and IGBT guides explain terms used in diagnosis.
Modbus and INVT Studio
The legacy selection table lists standard Modbus for the GD200-13. It also lists three analog inputs, eight digital inputs and one high-speed digital input. Use the applicable device documentation for terminals, communications settings and registers. The INVT Studio serial support list names the GD200 family. Verify the exact GD200-13 model, firmware and software profile before backing up parameters. See INVT VFD Software for the PC tool and INVT PLCs and INVT HMIs for related control equipment.
Editor’s Note
If you’re buying a used drive, ask for a readable nameplate photo first. That -13 suffix makes the replacement much easier to identify.
If the old drive has failed, capture the terminal labels and the last parameter backup before removal. Those records save time when the cabinet goes back together.
Ask whether the fan was replaced, whether the air duct is clean and whether the drive ran in a damp cabinet. Compare the answers with the service records.
If it trips only during deceleration, note the event time and the load at that moment. The first fault helps put later alarms into context.
Leave internal cabinet checks to qualified staff who can isolate the supply safely and verify that stored voltage has discharged.
Manuals and PDF documents
INVT VFD Documents is the drive library within INVT Technical Documents. The selection PDF below gives the GD200-13 its own column. The model-specific product manual archive entry is also linked.
Related topics
GD200 / Goodrive200 · GD200-01 PV pump drive · GD200-EU · Speed control accessories
INVT category path INVT brand home › INVT user manuals › INVT VFD drives
External references
INVT/WEM low-voltage drive selection table (English PDF) · GD200-13 product manual archive entry (Chinese)