Delta ASDA-A+

Delta ASDA-A+ Servo Drive Series

The Delta ASDA-A+ is a 220 V three-phase AC servo drive series rated from 4.5 to 7.5 kW. It runs compatible ECMA servo motors. In machine applications such as feeding, indexing and transfer, it supports position control through pulse-train commands or stored positions.

Drive codes and ECMA motor combinations

ASD-A4523-B, 4.5 kW · Delta lists ECMA-F21830□S, ECMA-E21835□S and ECMA-F21845□S motor options.

ASD-A5523-B, 5.5 kW · Matches the ECMA-F21855□3 motor.

ASD-A7523-B, 7.5 kW · Matches the ECMA-F21875□3 motor.

The 23 in these codes denotes the 220 V three-phase supply class. Check the cabinet supply and drive nameplate, then confirm the motor and drive combination by the complete model codes. Check the brake and shaft options on the ECMA motor. When sizing a motor for a new axis, use load inertia, continuous and peak torque, and cycle time.

Pulse input, stored positions and serial communication

Pt mode accepts a pulse train from a PLC or motion controller. On CN1, Delta specifies 500 kpps for standard differential input, 200 kpps for open collector input and 4 Mpps for the A+ dedicated high-speed differential input. When replacing the cable or controller, check the input terminals and P1-00 setting together.

In Pr mode, digital inputs select and trigger one of eight stored positions. In S and T modes, speed and torque commands can come from the analogue input or internal registers, depending on the operating mode. CN3 supports serial Modbus through one selected interface, RS-232, RS-485 or RS-422. On a Modbus RS-485 machine, check the station address, baud rate and RTU or ASCII framing settings in the existing project.

Encoder, cables and commissioning

CN2 is the motor encoder connector. Check the exact motor code and pin assignment when matching the feedback lead, even if the plugs look alike. See Delta servo cables for power, brake and encoder connections. Assess positioning accuracy by comparing commanded and actual travel and measuring homing repeatability.

Before changing drive settings, record the existing parameters from the panel or with compatible Delta software. After auto-tuning, monitor following error and settling time under load. Check the axis response during the actual work cycle.

Editor’s Note

Ask for the drive and motor nameplates when buying used. Record the exact motor code paired with an ASD-A4523-B. Delta lists several motors with different ratings and speeds for this drive. Check for darkened terminals, dirt around the fan and damaged connectors.

Test the machine’s command method after the JOG test. On a Pt machine, confirm that the drive receives commands at the actual pulse input and that feedback moves in the expected direction. On a Pr machine, check that the digital input selects the correct position record.

Save the scaling and home settings before removal. Record P1-00, P1-01, electronic gearing, digital I/O assignments and home offset. After fitting the spare, command a known distance in both directions and measure actual travel. This catches scaling errors before they affect the first part.

Record when ALE09 occurs. If following error increases during acceleration, check for binding and review the load and drive settings. If it recurs at a particular cable carrier position, inspect the connector and lead for shielding and electrical noise issues. Log the alarm code, travel direction and load in the maintenance record.

Check the braking resistor against the diagram for the exact drive. The 4.5 kW model has a built-in resistor. Delta shows an external resistor arrangement for the 5.5 and 7.5 kW models. If an alarm appears during deceleration, review the regenerative braking circuit with the load and stop ramp. For faults that recur as the machine warms up, log motor temperature and cabinet airflow.

Evaluate an A3 retrofit as a complete system. Delta names the ASDA-A3 as the successor to the discontinued A+. Check the new system’s tables for motor and encoder compatibility, supply, command signals and the braking resistor.

Delta ASDA-A+ PDF downloads

ASDA-A and ASDA-A+ User Manual · English, 23 April 2009, 383 pages. Drive and motor combinations, control modes, serial communication, parameters and alarms.

ASDA-A+ Installation and Wiring Sheet · Multilingual, 11 May 2009, 6 pages. English on pages 5–6. Wiring diagrams, mounting dimensions and cable tables for all three A+ models.

For documentation on other series, visit the Delta Servo Manuals archive.

Related topics and Delta equipment

Servo system FAQs · Delta servo communication units · Delta servo drive series

For other Delta drives, see ASDA-A, ASDA-AB and ASDA-A2.

Manufacturer reference · Delta Electronics ASDA-A+ series page