Delta DVP32ES211T

Delta DVP32ES211T — 24 V DC PLC with 16 Inputs and 16 Transistor Outputs

The Delta DVP32ES211T is a DVP-ES2 PLC CPU with a 24 V DC supply, 16 digital inputs, 16 NPN transistor outputs and 16K-class program memory. It suits conveyors, packaging equipment and pulse/direction positioning.

Power supply, inputs and output groups

Connect a nominal 24 V DC power supply to the CPU’s 24V and 0V terminals. Delta specifies a 20.4–28.8 V DC operating supply. The CPU can mount on a 35 mm DIN rail. Inputs X0–X7 and X10–X17 share a single S/S common. Wire that common to suit the NPN or PNP field sensors.

UP0/ZP0 serves Y0–Y7 and UP1/ZP1 serves Y10–Y17. Feed the UP/ZP groups in use from an external 24 V DC supply as shown in Delta’s diagram. The NPN outputs sink current to 0 V. For resistive loads, Delta specifies 5–30 V DC, 0.5 A per output and 4 A per common. For inductive loads, select any interposing relay, contactor and DC coil suppression diode to suit the load.

High-speed counting and pulse outputs

High-speed inputs X0 and X2 support single-phase counting up to 100 kHz. The input table rates X4–X7 at 10 kHz and X10–X17 at 60 Hz. An inductive sensor can detect passing metal parts while an incremental encoder measures movement. For A/B quadrature counting, check the input pair and frequency limit for the selected counter mode.

The transistor output limits are 100 kHz on Y0/Y2, 10 kHz on Y1/Y3 and 1 kHz on Y4–Y17. Select the pulse/direction starting address for the positioning instruction. Check whether the pulse input on the stepper motor or servo motor drive accepts an NPN sinking output.

Communications, software and programming cable

COM1 is an 8-pin mini-DIN RS-232 port. COM2 and COM3 are terminal-block RS-485 ports. COM2 uses SG2/D+/D− and COM3 uses SG3/D+/D−. Match baud rate, parity, stop bits and device addresses when setting up Modbus RTU with a drive, HMI or field device. See RS-232 and RS-485 differences and industrial communications for connection options.

Select the ES2 CPU target in WPLSoft or ISPSoft to build the ladder program. Use UC-PRG020-12A from a USB-equipped PC to COM1 or UC-MS020-01A from a PC with a DB9 RS-232 port. With ISPSoft, select the Windows serial port in COMMGR. See PLC programming and Delta PLC cables for more on programming connections.

Editor’s Note

When buying used, check for DVP32ES211T on the nameplate and locate the 24V/0V terminals. Match the panel supply to the device label and wiring diagram.

If the Y LED lights but the load stays off, measure the associated UP/ZP group first. Then trace the +24 V load feed and 0 V return with a multimeter.

If encoder counts become erratic when the drive starts, route the signal cable away from the motor cable. Check shielding, grounding and sources of electromagnetic interference.

If the PC cannot connect, confirm that the cable is on the 8-pin mini-DIN COM1 port, that its driver is installed and that the software is using the correct COM port.

Before replacing the CPU, back up the program, transferable retained data and settings for both RS-485 ports. Record the operator panel and drive addresses as well.

Check the sensor and output assignments one at a time with motion commands disabled for the first test. Verify the machine’s emergency stop circuit separately according to its safety design.

Related models and pages

The DVP32ES200T has the same I/O count with AC power and transistor outputs. The DVP32ES200R offers AC power and relay outputs. The DVP40ES200T has 24 inputs and 16 transistor outputs. See the DVP32ES200TE for Ethernet-equipped ES2 projects or the DVP32ES311T for DC-powered ES3 projects. For smaller machines, see Derell PLCs and smart relays.

Delta DVP-ES2 · DVP expansion modules · Delta DVP PLC series · Used Delta PLCs · Delta Automation

Manuals and wiring diagrams

Delta DVP PLC files

External references · Delta ES2 installation and wiring sheet · Delta DVP programming manual · Delta PLC cable selection guide · Delta DVP model catalogue