Delta DVP28SS211R | DVP-SS2 PLC with 16 Inputs and 12 Relay Outputs
The Delta DVP28SS211R is a compact PLC CPU in the DVP-SS2 series. It has a 24 V DC supply, 16 digital inputs and 12 relay outputs. Its 8k-step program capacity suits conveyor, packaging and general machine sequencing. It reads sensor states, evaluates them in the PLC program and switches field loads such as valves or contactor control circuits.
Power supply, digital inputs and relay groups
The 24 V DC supply range is 20.4–28.8 V DC. Digital input addresses are X0–X7 and X10–X17. Check the S/S common against the sink/source diagram and the output type of the inductive sensor or photoelectric sensor. For continuous signals, select an analog expansion module that matches the signal. See the digital and analog input comparison.
Relay output commons are C0 for Y0–Y2, C1 for Y3–Y5, C2 for Y6, Y7 and Y10, and C3 for Y11–Y13. The relay contacts switch the load’s external supply. Delta’s specifications list 250 V AC or below 30 V DC, with resistive-load limits of 1.5 A per output and 5 A per common. For inductive loads, check the manual’s contact life curve and suppression circuit.
The specified maximum relay switching rate is 1 Hz. For stepper or servo applications requiring high-speed pulse outputs, select the output type and frequency to match the drive input. The DVP28SS211T has the same I/O count and uses NPN transistor outputs.
WPLSoft, ISPSoft and programming cable
Use WPLSoft or ISPSoft for PLC programming. When taking over an existing project, check the project software and PLC firmware first. Use the COM1 RS-232 programming port to transfer or monitor a ladder program. Delta’s SS2 cable diagram shows the UC-PRG020-12A for USB and the UC-MS020-01A for a PC with a DB9 RS-232 port. Install the USB cable driver and select the resulting COM port. Set up ISPSoft communication in COMMGR.
Use COM2 RS-485 to communicate with field devices such as an HMI or a compatible remote I/O station. For serial Modbus, match the baud rate, data bits, parity, stop bits and device address, along with the ASCII or RTU mode. In an existing RTU-485 station, card order determines the special-module addresses. See the Modbus FAQ for protocol details.
Editor’s Note
Start with the label. When buying used, ask for a photo showing DVP28SS211R and the C0–C3 markings. Check for loose screws, cracked terminals and signs of overheating.
Back up the program. Save the PLC project, parameters and COM2 settings before replacement. Keep the original project file for comments and labels.
Test the inputs with known signals. With S/S wired correctly, verify a known signal in each group, X0–X7 and X10–X17, using the LED and online monitoring.
Check the relay on the load side. The Y LED indicates the PLC’s output command. Use a safe test load to verify that the relay contact switches and that each common has the correct supply.
Watch communication with loads running. If serial communication drops when a motor starts, check for interference and inspect cable routing and grounding.