Delta DVP20PM00D

Delta DVP20PM00D | 2-Axis 500 kHz Motion Control PLC

The Delta DVP20PM00D is a 100–240 V AC, two-axis motion control PLC in the DVP-PM series. It provides differential pulse outputs up to 500 kHz per axis for X and Y, eight general digital inputs, eight general relay outputs and 64k steps of program memory. The axes can position independently or move together along a programmed path.

FP/RP axis outputs, homing and relay terminals

FP0/RP0 serve the X axis and FP1/RP1 serve the Y axis. Each signal has a + and a − terminal. The controller supports pulse/direction, forward/reverse pulse and A/B phase formats. Check the differential input type and frequency rating of the servo drive or stepper motor drive. When commissioning a servo motor, match the drive’s pulse scaling to the controller’s mechanical units.

LSP/LSN serve the axis limit switches. The selected homing method determines how it uses the DOG and PG inputs. Check the signal format and +/− pairs against the manual when connecting a differential encoder or handwheel. X0–X7 are general digital inputs. Y0–Y7 are general relay outputs. Delta specifies resistive-load limits of 2 A per point and 5 A per common. Check the inductive-load curve for contactor or valve coils.

The controller supports two-axis linear and circular interpolation. G01 is used for linear motion, and G02 and G03 for circular motion. With the path and home position established, interpolation coordinates both axes along the contour.

PMSoft, COMMGR and programming cable

Use PMSoft for PLC and motion programming. The O100 main ladder program runs the machine sequence and calls OX motion subroutines. For a direct PC connection, use COM1 RS-232. Delta’s cable diagram specifies the UC-PRG020-12A for USB and the UC-MS020-01A for a PC with DB9 RS-232. Start the COMMGR driver, then select that driver and the correct controller in PMSoft’s Communication Setting screen.

COM2 RS-485 supports serial Modbus communication with an HMI or compatible field device. Match the station address, serial settings and ASCII or RTU format. For projects requiring Ethernet or CANopen, check the optional DVP-FPMC card and its supported functions. See the industrial communication guide for network selection.

Editor’s Note

Read the full label. When buying used, ask for a photo of the 00D suffix, FP/RP terminals and COM1 socket. The suffix matters when selecting both axis and general outputs.

Open and check the backup. Keep the PMSoft project, OX subroutines, any separate G-code files and the drive parameters.

Check direction and scale. Run the initial test at low speed with the travel area safe. Use a short movement on one axis to compare direction, pulse scaling and actual travel.

Monitor homing and limits separately. Check that DOG, PG and LSP/LSN change as expected before issuing a motion command.

Check pulse cable routing. If position drift appears when loads run, inspect the differential pairs, shield termination and grounding for sources of electromagnetic interference.