Delta DVP16ES200T

Delta DVP16ES200T – PLC with 8 Inputs and 8 NPN Transistor Outputs

Delta DVP16ES200T is a 100–240 V AC powered main PLC unit in the DVP-ES2 family, with 8 digital inputs and 8 NPN transistor outputs. It can control sensors, pushbuttons and actuators on small machines. The number 16 is the combined input/output count; this is a CPU that executes its own program. Assess both I/O requirements and load characteristics for conveyors, auxiliary packaging controls and sequential automation.

Program memory is in the 16K class; the manufacturer's programming manual specifies 15,872 usable steps. The onboard channels are digital. Select suitable expansion modules where analog I/O is required for measurement or control.

Inputs and addressing

Built-in inputs use X0–X7, and outputs use Y0–Y7. X/Y addresses follow octal numbering. When adding expansion modules, check the CPU’s reserved address area and module allocation table rather than assigning an address solely from the last physical terminal number.

Inputs support 24 V DC sink/source wiring. Configure the S/S common to match the NPN/PNP arrangement, then check sensor and limit switch signals accordingly. For high-speed counting, check the encoder output type, channel assignment and input filter together. A line driver encoder output is not electrically identical to an ordinary 24 V input signal.

Transistor outputs and pulse frequencies

Outputs are NPN open collector. The instruction sheet specifies a resistive-load limit of 0.5 A per point and 4 A per common group. Wire the field supply for the single UP/ZP output group according to the manufacturer's NPN circuit. Powering the CPU alone does not establish the output load supply.

The manufacturer's output table distinguishes Y0 and Y2: 100 kHz; Y1 and Y3: 10 kHz. Y4–Y7 have a specified switching limit of 1 kHz; they are not positioning channels with the same performance. Check channel pairing and instruction support for pulse/direction or CW/CCW operation. A transistor output is not electrically equivalent to a 5 V differential line-driver output.

DC valves and interposing relay coils require a load current calculation, suitable fuse protection and suppression. Check voltage and load type before connecting a contactor coil. Observe the polarity of a diode across a DC coil. Do not connect an AC load directly to these outputs.

Power supply and panel wiring

Connect 100–240 V AC to L/N. The instruction sheet lists 30 VA consumption and a 24 V DC / 500 mA auxiliary output. This 500 mA is a shared budget for input circuits and external loads, rather than an additional unrestricted load allowance. Do not arbitrarily parallel an external 24 V power supply with the PLC's auxiliary output.

Check grounding, terminal tightness and possible load-side short circuits. The normal PLC program does not replace the emergency stop and safety relay circuit.

Programming software and cable

WPLSoft and ISPSoft are programming tools for DVP-ES2. Select the ES2 CPU target in the PLC programming project and assess the existing Ladder program, instructions and CPU firmware together. Firmware conditions for the older ES family must not be transferred unchanged to ES2.

Programming uses COM1 RS-232 with an 8-pin mini-DIN connector. The manufacturer's ES2/EX2 cable table lists the UC-PRG020-12A USB programming cable and the UC-MS020-01A RS-232 cable. The latter requires a suitable PC serial port or USB-to-RS-232 converter. Install the USB cable driver and select the correct COM number. For ISPSoft, configure the COMMGR serial driver and port settings.

Communication and expansion

The standard CPU has one RS-232 and two RS-485 ports: COM1 is RS-232, while COM2/COM3 are RS-485. Match station, baud rate, parity and protocol settings for Modbus ASCII or Modbus RTU. There is no native Ethernet or USB port.

Assess the ES2 expansion interface, module supply and address allocation together. Where more I/O is required, compare compatible expansion modules with a larger CPU in terms of panel space, wiring and power budget.

Editor's Note

Check the T ending on DVP16ES200T. Replacing a relay-output R model requires a fresh check of DC loads, NPN wiring and the output common. A matching I/O count alone does not establish equivalence.

For a used unit, test all eight inputs and all eight outputs separately. If an output LED lights but the load remains off, measure the UP/ZP supplies and common return before concluding that the CPU is faulty.

Check pulse operation on Y0 and Y2 with a suitable receiver or oscilloscope. An average voltage reading on a multimeter does not establish pulse frequency or edge quality.

Back up the project, necessary retained data and serial-port settings before making changes. Downloading a program or forcing outputs can affect machine movement.

Review loose terminals, corrosion, burn marks and previous repairs using photographs. Check power-restoration behaviour under controlled conditions. These notes are not completed test results for a particular unit.

Related models

DVP16ES200R is the relay-output option with the same 8-input/8-output count; it does not replace high-speed transistor pulse outputs. DVP24ES200T offers 16 inputs/8 transistor outputs, DVP32ES200T offers 16 inputs/16 transistor outputs, and DVP40ES200T offers 24 inputs/16 transistor outputs. Assess these candidates against the required I/O count and check terminals, programs and supplies before replacement.

PDF documents and related topics

Visit our Delta DVP PLC files page. The existing Turkish DVP-ES2 installation and wiring sheet and English/Chinese DVP-ES2 instruction sheet cover this model. EX2 analog tables within the shared document do not establish onboard analog channels on DVP16ES200T.

Related topics: NPN/PNP wiring principles, evaluating encoder signals and RS-485 field communication.

To offer used equipment, send the brand, complete model, quantity, working/fault condition, label photographs and asking price to otomasyonavm@gmail.com. Sales require an invoice, with no returns; workshop testing may be arranged. Confirm the item's condition and test scope before purchase.

Delta used models | Delta PLC | Delta DVP series | Delta DVP-ES2 | DVP16ES200T main page | DVP PDF files

External references

Delta DVP-ES2/EX2 series catalog, 5 January 2010: model selection and series specifications. Delta DVP-ES2/EX2 and related series programming manual, 10 February 2023: memory map and instruction support. Delta PLC/HMI Cable Selection Guide, 15 August 2019: ES2/EX2 section 1.1. Manufacturer's ISPSoft help manual: supported CPU families.