Delta DVP04PT-SH
Delta DVP04PT-SH – DVP Slim PT Temperature Measurement Module
Delta DVP04PT-SH is a PT temperature measurement expansion model in the DVP Slim family. Delta's Rev.28 declaration dated 5 November 2024 lists the exact code with the description 4/0PT DC. This classification indicates four PT input points with no output points. It is included under DVP Slim specialty modules and is not a standalone replacement for the host PLC CPU.
Model distinction: DVP04PT-S and DVP04PT-SH appear as separate entries in the manufacturer's document. Do not automatically apply the S model's measurement range, resolution, sensor list or control registers to the SH version. An SH-specific operating sheet has not been verified, so exact sensor ranges, channel modes and register addresses are not stated here.
PT sensors and measurement principles
RTDs such as Pt100 measure temperature through a change in resistance. Pt100 has a nominal resistance of 100 Ω at 0 °C; Pt1000 belongs to the 1,000 Ω class at that temperature. These general definitions do not establish that DVP04PT-SH supports both sensor types. Match the sensor and characteristic curve to the exact module.
The difference between Pt100 and thermocouples matters when selecting a connection. A thermocouple, an RTD and an NTC sensor use different measurement arrangements. A probe label saying only “temperature sensor” is insufficient; identify its element type, nominal value and wire count.
Temperature measurement is an analog input application. Unlike a digital input that reports an on/off state, it converts a measured quantity into numerical data. Correct interpretation in °C, °F or resistance units requires the actual module data format and scaling.
Wiring considerations
Two-wire RTD measurements can include lead resistance; suitable three-wire circuits can compensate for it. Verify DVP04PT-SH's supported wiring method and terminal order against its own connection diagram. Do not transfer L+, L− or I− terminal assumptions from a similar-looking card.
Route sensor cables separately from motor and drive power cables. Arrange shielding and grounding according to the cabinet design. Do not apply an external supply voltage to a sensor input; RTD excitation current is a function of the measurement circuit.
Check the label, cabinet diagram and manufacturer instructions together when assessing supply and CPU expansion compatibility. A cabinet containing a 24 V power supply does not establish that every terminal accepts 24 V. Isolate power and identify the relevant fuse circuit before changing wiring.
Programming software, cable and data access
Select the PLC programming tool for the host CPU. Compatible DVP CPU projects may use WPLSoft or ISPSoft; ISPSoft communication uses COMMGR. These software names alone do not establish CPU compatibility with DVP04PT-SH.
Where the CPU has a suitable 8-pin mini-DIN RS-232 port, match UC-MS020-01A (2 m), UC-MS030-01A (3 m) or the USB-connected UC-PRG020-12A to the exact CPU. Use the CPU port specification and cable pinout when establishing the programming connection.
Before bringing measurements into the Ladder application, verify the SH module's register map, signed data format and scaling. Do not reuse DVP04PT-S FROM/TO examples, CR numbers or Modbus addresses without confirmation. Back up the working project's module order and settings before replacement.
Applications and control logic
In an automation system, temperature readings can support process monitoring, alarms or calculations in the host CPU. For PID control, assess measurement update time, physical sensor response and output hardware together. Implementing PID in a PLC does not establish that the input module has an independent onboard PID function.
Related measurement modules
Consider DVP04PT-S and DVP06PT-S when comparing RTD measurement requirements. DVP04TC-S serves thermocouple applications, while DVP04AD-S provides a different approach for reading an external temperature transmitter's voltage/current signal. These are not presented as direct DVP04PT-SH replacements; compare CPU, sensor and application compatibility separately.
Editor's Note
If the label says DVP04PT-SH, retain the final H when ordering. Photograph the full code, hardware revision and existing CPU information.
Back up the working application and parameters before removing a card. Label sensor wires by channel; mixed-up conductors can make a replacement appear faulty.
Test with an RTD simulator or precision resistance source appropriate to a sensor type confirmed as supported. Do not connect an arbitrary resistance and interpret the result without knowing the required sensor characteristic.
Check every channel separately. For a single-channel offset, inspect field wiring and terminal contact first. For a shift affecting all channels, assess shared supply, reference and configuration.
Perform short-circuit and resistance checks with power isolated and the sensor disconnected from the card. Measuring resistance through a connected sensor can be affected by the input circuit.
For a used-unit sale, state quantity, label photographs, working/faulty condition and the sensor used for testing. Sales require an invoice; no returns; workshop testing is available. Sellers can send details to otomasyonavm@gmail.com.
PDF documents and related topics
Visit our Delta DVP PLC files page first. The exact DVP04PT-SH code appears on PDF page 3 of the Rev.28 declaration. This confirms model identity; it is not an operating manual specifying sensor ranges and wiring. DVP04PT-S/DVP06PT-S manuals should not be described as SH-specific documentation.
Related topics and navigation: Delta and used models | Delta PLC | DVP series | Expansion modules | Slim specialty modules | DVP04PT-SH model page
External references
Delta DVP Slim Declaration of Conformity – Rev.28, 5 November 2024, English
NI – General RTD measurement principles; not an SH-specific manual
Delta PLC/HMI Cable Selection Guide