Delta DVP-ES2 Ethernet
Delta DVP-ES2 Ethernet (DVP-ES2-E)
The Delta DVP-ES2-E is a compact PLC CPU with built-in RJ45 Ethernet and a 100–240 V AC supply. It can read inductive sensors and photoelectric sensors on a conveyor or packaging station and command a variable-frequency drive. With a compatible driver, the same CPU can send production counts and fault status to an operator panel or a SCADA system.
Model codes and built-in I/O
| Digital inputs | Digital outputs | Relay output | Transistor output |
|---|---|---|---|
| 12 | 8 | DVP20ES200RE | DVP20ES200TE |
| 16 | 16 | DVP32ES200RE | DVP32ES200TE |
| 24 | 16 | DVP40ES200RE | DVP40ES200TE |
| 36 | 24 | DVP60ES200RE | DVP60ES200TE |
RE identifies the relay-output Ethernet variant and TE identifies the transistor-output Ethernet variant. Check for the final E on the nameplate before ordering. The DVP32ES200T and the DC-powered DVP32ES211T belong to the standard DVP-ES2 group. The DVP32ES200RC and DVP32ES200TC belong to the ES2 CANopen group.
The digital inputs take 24 V DC signals. Check the S/S common in the sink/source wiring diagram for your PNP or NPN sensors. On RE models, check the relay contact load rating. On TE models, use the wiring sheet to verify the output commons and load polarity. For an incremental encoder or pulse control, check the high-speed X/Y terminals for the exact CPU. For 0–10 V or 4–20 mA, check the analog and digital input requirements. Use a suitable ES2/EX2 expansion module or see the DVP-EX2 family if the application needs built-in analog I/O.
Programming software and cables
Use WPLSoft to read, edit and monitor a Ladder project. In WPLSoft, select Ethernet as the communication type and enter the PLC’s IP address. For service work on an existing WPLSoft project, save a copy of the original first. To connect with ISPSoft, create and start an Ethernet connection in COMMGR. Select the correct PC network adapter and the PLC’s current IP address, then choose that driver in ISPSoft and go online.
For Ethernet access, use a Cat5e RJ45 patch cable. Connect the PC directly or through an Ethernet switch. Check the Ethernet cable length and routing on site. In DCISoft, select Ethernet → Search to discover the unit and read its network settings. Delta documents 192.168.1.5 / 255.255.255.0 as the factory setting. Check the actual address on a used unit and assign the PC a different address in the same subnet for a direct bench connection.
For serial access, the PLC’s COM1 port is an 8-pin mini-DIN RS-232 interface. Delta manuals list the DVP-ACAB2A30, DVP-ACAB2B10 and UC-MS030-01A cables. If the PC has no DB9 port, install the USB-to-RS-232 adapter driver and select the COM port assigned by Windows. See Delta PLC programming cables for connection options.
Using Ethernet and RS-485 on one machine
The built-in Ethernet port supports Modbus TCP. The default Modbus TCP port is 502. With a Delta DOP-100 panel, verify the HMI driver, PLC IP address and register address together. COM2 and COM3 are RS-485 ports. For serial Modbus RTU, match the station address, baud rate, parity and stop bits to the other device. The panel can use Ethernet while a drive on the same machine uses RS-485. Record both sets of settings in the industrial communications plan.
Editor’s Note
When buying used, start with a photo of the side label. Check the complete model code, supply and output type before powering the unit.
Check that the RJ45 plug latches, the link stays up and the software can see the PLC. Each check tells you something different.
If the old CPU still starts, back up the program and network settings first. Check both IP addresses before putting the old and replacement CPUs on the same network.
When a Y indicator turns on, verify the output with a suitable test load. Check the contact on an RE unit and the common and load supply on a TE unit. Disable machine motion for the test.
If communication drops when the drive starts, check for electromagnetic interference, inspect the cable route and check cabinet grounding.
Related topics, internal references and PDF files
Delta DVP PLC files · Delta DVP-ES2 series · Delta DVP-SE · Delta DVP-ES3
External references
Delta ES2-E wiring sheet (includes English and Turkish) · Delta ES2 wiring and Ethernet setup sheet (EN) · Delta DVP programming manual (EN) · Delta ISPSoft user manual (EN)