6ES7 133-0BN11-0XB0

Siemens 6ES7 133-0BN11-0XB0 – ET 200B Digital Input/Output Module

The 6ES7 133-0BN11-0XB0 is a digital electronics block for the Siemens ET 200B distributed I/O system, part of the ET 200 family. It combines 24 digital inputs and 8 digital outputs, all rated at 24 V DC, in one block. Field data is exchanged with the main PLC over PROFIBUS DP.

The electronics block is not a CPU and does not run the machine program by itself. It operates with a suitable PROFIBUS DP master, such as an S7-300 controller. The controller evaluates input data and sends commands to the outputs. For an overview of the family, see about Siemens ET 200.

24 digital inputs and input delay

The 24 V DC inputs read the on/off states of suitable sensors, pushbuttons and switches. For example, inductive sensors on a conveyor can send part-detection signals to the station. Related product groups include digital input modules and combined digital I/O modules.

Siemens specifies a maximum input delay of 0.2 ms for the transition from 0 to 1. This is the input circuit's delay, not the complete response time of the PLC program, PROFIBUS network and output. When short pulses must be detected, assess the sensor's pulse duration, network cycle and controller scan together.

Check the sensor output type and common connection before wiring. The sink and source page provides background, while the actual module and sensor diagrams must be used for the final connection.

8 digital outputs and current limits

The block has 8 digital outputs rated at 24 V DC. Each output is limited to 0.5 A, while the total current for the eight-channel output group is limited to 2 A. For example, drawing 0.5 A from all eight outputs simultaneously would total 4 A and exceed the group limit.

Outputs can control suitable relay coils, valves or indicator devices when their voltage and current requirements are within specification. Check both continuous and inrush current, as well as the behaviour of inductive loads. Electronic short-circuit protection does not remove the specified load limits. For other output types, see PLC output modules.

Power supply and terminal block

The electronics block is supplied with 24 V DC. The Siemens data sheet lists a permitted module supply range of 18.5–30.2 V DC. The power-supply and wiring requirements in the ET 200B system manual must also be observed. When selecting a power supply, account for the sensors and output loads as well as the electronics block.

The 6ES7 133-0BN11-0XB0 is an electronics block and requires a compatible ET 200B terminal block. Siemens documents list TB2/DC, TB2-4/DC and TB4/DC among the compatible options. Field wiring connects to the terminal block, and the electronics block is mounted on it. Check the terminal type, coding and wiring diagram before installation.

The ET 200B connection arrangement differs from the S7-300 module layout used in ET 200M. When reviewing ET 200 connection modules and ET 200 accessories, compare the product family and complete order number.

PROFIBUS DP and configuration

The station communicates over PROFIBUS DP at speeds up to 12 Mbit/s. The actual rate depends on the master and the other network components. The PROFIBUS connection is made through the terminal block; this device has no direct PROFINET or Ethernet port.

The ET 200B station number is set using switches on the terminal block. According to the Siemens manual, the new address becomes valid after a STOP–RUN transition. Assess the machine and output states before performing this operation. In STEP 7 or the master's configuration tool, the selected device, station address and I/O addresses must match the installed hardware. Other network options are covered under ET 200 communication interfaces.

Difference between 0BN01 and 0BN11

The 6ES7 133-0BN01-0XB0 and 6ES7 133-0BN11-0XB0 have the same 24-input/8-output arrangement. However, Siemens lists an input delay of 3 ms for the 0BN01 and 0.2 ms for the 0BN11. Matching channel counts alone do not establish that the two devices can be exchanged in every application.

When selecting a replacement, check the complete order number, input delay, terminal block, project configuration and master compatibility. The delay difference matters particularly when the machine monitors short field signals.

Installation and fault checks

Siemens lists dimensions of 235 × 130 × 60 mm for the electronics block and terminal block together, with an IP20 protection rating. Install the equipment in a suitable enclosure and observe the mounting and ventilation requirements.

The RUN indicator provides information about the logic supply, while BF indicates a PROFIBUS bus fault. Individual input and output LEDs show channel states. For a communication fault, first check the station address, PROFIBUS connector, cable, termination and project configuration.

If an input LED does not change, check the sensor supply and the actual input signal. If an output LED is on but the load does not operate, check the output-group supply, load wiring and current. Also read the PLC CPU diagnostics. An alarm on an operator panel or SCADA system does not by itself prove that the electronics block has failed.

Editor's Note: Two details are easy to overlook: the 2 A total output-group limit and the input-delay difference between the 0BN01 and 0BN11. When selecting a spare, check the existing terminal-block code as well as the electronics block. Disconnect the relevant supplies according to the manufacturer's instructions before removing the block or changing its wiring.

Manuals and related topics

For terminal wiring, pin assignments, station addressing and diagnostics, visit the Siemens ET 200 manuals and PDF documents page.