Siemens 6ES7 193-1FH60-0XA0 — ET 200L two-tier spring supplementary terminal
The Siemens 6ES7 193-1FH60-0XA0 is a two-tier supplementary terminal with spring connections for a 16-channel ET 200L arrangement. Part of the SIMATIC ET 200 range, it provides additional field-wiring connections beside the station. Siemens documentation calls it a supplementary terminal or additional terminal. It belongs with the ET 200 terminal blocks and accessories.
The 16-channel description refers to the wiring arrangement. Fitting this accessory does not add 16 electronic inputs or outputs. The electronics block handles signal acquisition and output switching; that hardware determines the I/O available to the PLC.
What does the supplementary terminal do?
It extends an ET 200L two-wire termination arrangement to support three- or four-wire connections. The extra connection points help keep the additional conductors together at the station. This is a wiring extension, rather than an additional measurement or control function.
For a digital input, consider the sensor supply, return and signal path together. For a digital output, consider the complete load circuit. A suitable terminal does not establish electrical compatibility between the field device and the I/O electronics. With three-wire DC sensors, sinking/sourcing and PNP/NPN compatibility still depend on the input circuit.
Each tier has an internal common connection
Siemens states that the terminals within each tier are internally bridged. Individual positions on the same tier are therefore not separate signal terminals. Connecting unrelated sensor outputs to that tier would join those signals together. This distinction matters whenever an extra connection point is mistaken for an extra I/O channel.
The M reference, protective earth PE and an I/O signal serve different purposes. Follow the terminal markings and the wiring diagram for the complete assembly. Cable colour or the position used by a previous installer is not enough to establish the correct connection. A fault in a shared conductor can affect several field devices, so shared paths deserve attention during troubleshooting.
TB 16L compatibility and identification
The FH60 is listed among the 16-channel supplementary terminals for TB 16L. It is distinct from the main terminal block. For example, 6ES7193-1CH00-0XA0 identifies a screw-terminal TB 16L and 6ES7193-1CH10-0XA0 a spring-terminal TB 16L. 6ES7193-1FH60-0XA0 identifies the add-on terminal accessory.
Match the ET 200 variant, full order number, number of tiers and connection type when selecting a replacement. ET 200L accessories, ET 200S terminal modules and ET 200SP BaseUnits belong to different mechanical systems. Our ET 200 overview explains the families; the connection modules section covers other connection components.
Similar part numbers and their differences
6ES7193-1FH20-0XA0: one tier, 16 channels, screw terminals. 6ES7193-1FH30-0XA0: two tiers, 16 channels, screw terminals. 6ES7193-1FH50-0XA0: one tier, 16 channels, spring terminals. The model on this page, 6ES7193-1FH60-0XA0, combines two tiers with spring terminals.
6ES7193-1FL60-0XA0 also has two tiers and spring connections, but serves a 32-channel arrangement. FH60 and FL60 are therefore different parts. Record the complete code from the existing assembly before ordering, especially where an old parts list uses an abbreviated description.
Installation and spring connections
The supplementary terminal slides into the guideways beneath the main terminal block and locks into place. Check its seating and latch before wiring. The spring contact is opened with the appropriate tool to accept the conductor; the screw-terminal tightening procedure does not apply to this connection. Use the manual’s wiring section to select conductor size, stripping length and ferrules.
Before maintenance, place the machine in a safe state, isolate the relevant supplies and verify that the wiring is de-energised. Record conductor labels and tier assignments before removal. Inspect the latch, spring contacts and insulation for damage, corrosion or signs of heating. An intact housing alone does not prove that a terminal still grips the conductor properly.
Power, communication and software
The FH60 helps distribute the required connections; it does not generate or convert a voltage. Power supply modules and power distribution components have different roles within an installation. Establish the permitted current and voltage from the applicable terminal system and manufacturer limits, rather than inferring a rating from the channel count.
ET 200L PROFIBUS DP communication is handled by the electronics block. This supplementary terminal has no separate network address, GSD file or user program. Replacing the same accessory does not by itself add another bus station. A system that needs PROFINET requires the appropriate communication hardware; changing a terminal accessory does not convert the network protocol.
A practical approach to troubleshooting
If a sensor appears to operate but its state never reaches the PLC, check the sensor output, the actual signal terminal and the common return path together. If several signals fail at once, include their shared supply and connections in the investigation. These are useful checks, not proof that the supplementary terminal itself has failed.
With an inductive sensor, output type and input compatibility matter. A two-wire sensor has its own connection requirements. The FH60 cannot correct an incompatible signal interface. Moving a conductor to another common terminal without checking the circuit can introduce a second fault.
Manuals and PDF documents
Use our Siemens ET 200 user manuals and PDF documents page to find the relevant documentation. In ET 200L, ET 200L-SC and ET 200L-SC IM-SC Distributed I/O Device, section 7.6 identifies the supplementary terminal versions, section 2.1 covers installation and section 3.3 covers wiring rules. These references apply to EWA 4NEB 780 6009-02c; section numbers can differ in other editions.
Technical references: Siemens ET 200L system manual and the 6ES7193-1FH60-0XA0 product data sheet. The Siemens sheet dated 20 March 2012 lists an approximate weight of 140 g. Historical technical data does not establish current availability or the contents of a particular sales offer.
Editor’s note: A useful identification phrase is “ET 200L, 16 channels, two tiers, spring supplementary terminal.” Then match the complete part number. The internal bridging is easy to overlook: multiple wire openings do not mean multiple independent signal paths.