6ES7 181-0AA00-0AA0

6ES7 181-0AA00-0AA0 – Siemens BT200 PROFIBUS Tester

Series: SIMATIC DP / BT200
Category: PROFIBUS-DP physical bus and RS-485 test device

Description and system role

6ES7 181-0AA00-0AA0 is the Siemens BT200 portable PROFIBUS-DP tester. It supports installation and maintenance checks on PROFIBUS networks serving ET 200 stations. It is service equipment for the cabling and electrical interfaces of PROFIBUS networks, rather than an I/O module fitted to the station.

In a SIMATIC S7 or S7-300 installation, it helps investigate whether a communication problem between the PLC and a remote station originates in the cable or the station interface. Check the network type when assessing the ET 200 system. BT200 should not be selected as a PROFINET/Ethernet cable tester.

Technical design

Connection: 9-pin D-sub, PROFIBUS-DP / RS-485. Baud-rate range: 9.6 kbit/s–12 Mbit/s. Display: 2 × 16-character LCD. Original power source: 4.8 V NiCd battery. The 03/1999 BT200 manual specifies dimensions of 210 × 100 × 55 mm and an operating temperature of +5 to +45 °C.

The tester's battery and the station's power supply serve separate purposes. A battery fitted to a used tester may no longer hold a useful charge; check its condition and the matching charging equipment.

Available checks

Cable testing helps identify reversed A/B conductors, short circuits, conductor or shield breaks and termination problems. Inspect PROFIBUS connections and the shield braid inside connectors carefully. Cable-length and reflection measurements help locate a suspect section of the network.

The RS-485 station test checks an individual slave interface. The branch test can list accessible slaves. These results do not constitute a complete functional test of the station's digital inputs, digital outputs, analog modules or function modules.

Connection conditions for each test

For the cable test described in the 03/1999 manual, disconnect the stations from the bus cable and fit the test plug at the opposite end. For the RS-485 slave test, power the slave and connect it directly to BT200 using the specified test cable.

For a branch test, disconnect all masters and select the bus baud rate on BT200. Reflection testing also requires a bus with no data traffic. Plan the connection arrangement for the selected test before working on the network.

Versions and accessories

Siemens documents logging, master-interface testing and cable testing with stations connected as added features of BT200 Version 2. Do not assume these features on a unit labelled 6ES7 181-0AA00-0AA0; verify its version, menus and accessories. V2 connection procedures should not automatically replace those in the earlier manual.

Confirm whether the test plug, correct test cable, battery and charger are included. The original BT200 manual lists the charging cradle as a separate purchase. Match accessories by their specification, not just connector shape. The test plug is a different component from a station terminal block or an ordinary termination connector.

Interpreting results during maintenance

Review a communication alarm on an operator panel or SCADA system alongside PLC diagnostics, station addresses and physical measurements. A slave that does not respond is not necessarily defective; investigate its address, supply and connection as well.

On a used BT200, inspect the LCD, keypad, D-sub socket and charging contacts. Where possible, request a demonstration using a known-good cable and a suitable slave. A damaged test lead can resemble a network fault, so check the accessories together with the instrument.

Editor's Note

A working display is not a sufficient test of a BT200. Measurement performance, battery condition and a complete accessory set all matter. A low purchase price can be misleading if the test plug or correct lead is missing. A healthy cable result also does not establish that the machine program and every connected module are functioning correctly.

PDF documentation and user manuals

In the BT200 Physical Bus Test Device for PROFIBUS-DP manual, chapters 3 and 4 cover testing and chapter 6 covers accessories. Consult the separate V2 document when comparing versions. Visit Siemens ET 200 PDF and user manuals for the documentation page.

Related topics

PROFIBUS and PROFINET interfaces · ET 200 connection modules · ET 200 additional modules · Terminal blocks · Siemens S7-300