6ES5 755-4AA11
Siemens 6ES5 755-4AA11 – N-Type Coaxial Connector Set for SINEC H1
Siemens 6ES5 755-4AA11 is an N-type coaxial connector set for SINEC H1 / SIMATIC NET Industrial Ethernet cabling, including installations using SIMATIC S5. The standard set contains two connectors and parts for the outer screen connections. It is a passive accessory providing mechanical and electrical connections within the industrial communication network.
The application is the older SINEC H1, IEEE 802.3 10BASE5 bus architecture, operating at 10 Mbit/s over 50 Ω triaxial cable. That rate describes the network; the connector does not process data. What is Ethernet? and the history of Ethernet provide background on this physical network arrangement.
Standard set contents and completeness checks
The Siemens installation materials table lists one fixing bracket, two connectors, two rubber caps, two outer screen connection pieces and two heat-shrink sleeves under 6ES5 755-4AA11. For used equipment or an opened package, confirm whether the actual offer includes this complete standard set.
Counting the parts is only the first check. Connector pins, crimp components, insulators and caps must also be suitable for assembly. Replace missing or cracked protective parts with materials appropriate to the cable and installation arrangement.
Bus cable, transceiver and CP 535 connections
The N-type connector is used on the 727-0 SINEC H1 bus cable. The 727-1 drop cable between the equipment and transceiver is a separate connection. When reviewing S5 cables and connectors and Ethernet cable types, distinguish the trunk, equipment connection and connector functions.
An installation may include a 6ES5 755-0AA13 transceiver and a 6ES5 535-3LB11 CP 535. The 755-4AA11 does not perform the functions of an active transceiver or communication processor; it provides a coaxial bus connection. Keep the CPU/CP interface separate from the N-type connection on the bus side.
For installations containing 6ES5 535-3LB12 or 6ES5 535-3MA12, identify the actual connection path first. Record the complete part numbers for the S5 interface hardware, transceiver, drop cable and bus cable. The CP name alone does not establish connector suitability for the complete installation.
Connector and terminating resistor roles
The 755-4AA11 is not a terminating resistor. Siemens lists the 6ES5 755-3AA11 termination set separately. The 50 Ω terminations at both ends of a SINEC H1 segment must be preserved according to the network diagram. 6ES5 755-2CA11 is another separate product; a shared 755 number does not establish interchangeability.
Where network components such as a 6ES5 755-1AA12 repeater are installed, identify segment boundaries on the drawing before working on the cable. Operational S5 communication modules do not by themselves establish correct physical bus termination. Record which segment and endpoint were affected by a connector replacement.
Assembly, screening and workmanship checks
The manufacturer’s assembly procedure uses appropriate crimping tools for the connector pin and crimp sleeve. Match cable preparation dimensions, assembly order and die selection to the installation instructions. Rebuild a damaged pin or incorrectly crimped sleeve using suitable parts instead of trying to correct it by squeezing the outside.
The braided outer conductor of the inner coaxial cable and the outer protective screen have different roles. Fit the outer screen connection pieces and insulating rubber caps according to the installation plan. An arbitrary PE bond to the metal N-connector housing can alter the manufacturer’s screening and grounding arrangement.
When investigating communication trouble on an S5 CPU, record physical connection checks separately from program analysis. Centre conductor, outer conductor and unintended short-circuit checks can be made on a de-energized cable isolated appropriately for the measurement; actual network data exchange must then be verified. See About Siemens S5 PLC for system background.
Interpret resistance readings together with the connected terminations and other network components. The Ethernet FAQ covers general topics; acceptance criteria for this older coaxial installation should come from the applicable Siemens installation and network documentation.
Editor’s Note
When buying a connector set as used Siemens equipment, inspect the contents before the box. Ask for separate photographs of both connectors, screen connection pieces and protective parts. Confirm the supplied items in writing so that an advertised set does not turn out to be a single used plug.
Check the centre pin, insulator and threads of the N-type connection. Distorted housings and signs of forced assembly deserve attention. If cable weight is pulling directly on the connection, correct the mechanical support before accepting the repair.
Keep the inner braided conductor and outer protective screen distinct. Screen connection points and preserved insulation matter on this older triaxial network. Retain the rubber caps and heat-shrink parts as required by the assembly instructions.
Use the correct crimp die and inspect the finished joint visually and mechanically. A stray conductor strand can cause trouble across the network. Record continuity and short-circuit checks together with the cable ends and components disconnected for the measurement.
Track the spare under the complete 755-4AA11 number within the S5 accessories and expansion modules. After replacement, verify stable communication under a controlled test, beyond confirming that the equipment powers up. Keep photographs of the completed connection for the next maintenance visit.
OtomasyonAVM resources and PDFs
+ S5 cables and connectors · S5 communication modules · About Siemens S5 PLC
+ Shared SIMATIC S5 PDF archive – S5-115 PDF files. Use the Siemens triaxial network manual below for the connector set contents and assembly procedure.
Related topics
+ 6ES5 755-3AA11 termination set · 6ES5 755-0AA13 transceiver · 6ES5 535-3LB11 CP 535
Browse SIMATIC S5
+ S5 accessories and expansion modules · Siemens SIMATIC S5 · Used Siemens equipment