6ES5 451-4UA13

Siemens 6ES5 451-4UA13 — 32-Channel 24 V DC / 0.5 A Digital Output Module

6ES5 451-4UA13 is a 32-channel, 24 V DC electronic digital output module rated at 0.5 A per channel for Siemens SIMATIC S5 systems. Its digital outputs switch DC field loads. The load supply range is 20–30 V DC, and the specified switching current is 5 mA–0.5 A.

This compact U-series module is used in the context of S5-135U, S5-150U and S5-155U controllers and their associated U-series expansion units within the SIMATIC S5 family. All 32 outputs form one galvanically isolated group; individual channels are not isolated from each other. Check the installed S5 rack, module arrangement and cooling conditions together.

Combined load, ventilation and temperature

The combined current of each eight-output group must not exceed 4 A. The system manual specifies total load capability of 100% with a fan; without a fan, 100% up to 35 °C and 50% above that temperature. Common operating conditions specify 0–55 °C and a 40 mm module pitch without a fan. Calculating 32 × 0.5 A = 16 A does not establish an allowable continuous load for every cabinet arrangement.

When selecting relays, contactors and interposing relay coils, check channel current, the combined load of each eight-channel group and cabinet temperature. Maximum switching frequency is 100 Hz for resistive loads; for inductive loads it is 2 Hz at 0.3 A or 0.5 Hz at 0.5 A. Maximum off-state leakage is 0.5 mA, and the lamp-load limit is 0.22 A / 5 W.

Load supply and enable input

Check the field load supply separately from the S5 system power supply. The F+/F− enable input is rated at 24 V DC, with a logic-1 range of 13–33 V and rated input current of 5 mA. The enable input is active with jumper X20 inserted; this is the factory setting.

If an output does not operate, check the load feeds, enable voltage and jumper setting together. In expansion units, also inspect the interface connection and controller fault state. The enable input and load supply terminals perform different functions.

Front connector and wiring

Within the 42-pole connector family, 497-4UA12 is a 20 mm wide crimp connector and 497-4UB12 is a 40 mm wide screw-terminal connector. The manual lists the single-width crimp option for fan-cooled arrangements. When checking S5 cables and connections, match connector width, module spacing and cooling conditions together.

The module diagram identifies F+: 1, F−: 2, 1L+: 3, 2L+: 24 and H+: 22, with L− connections at 21 and 42. There is one 6.3 A slow-blow fuse per eight outputs. Fuse groups are not separate galvanic isolation groups.

LED indication and H+ signaling

Green LEDs indicate channel status; red LEDs indicate a short circuit within an eight-output group. H+ is the common short-circuit signaling output, rated at 10 mA maximum; it requires a supply at 1L+. Comparing the PLC program command with the output channel under actual load helps fault diagnosis. Establish safe machine conditions before testing.

Comparing versions and related modules

Evaluate 451-4UA11, 451-4UA12 and 451-4UA14 using their complete suffixes. Siemens’ U Periphery supplement states that 4UA13 and 4UA12 have the same functions and technical data. The later 4UA14 specifies a 7 A fast fuse; this must not replace the 6.3 A slow-blow specification for 4UA13.

453-4UA12 and 454-4UA12 provide comparisons of different channel counts, current ratings or isolation arrangements. These links do not establish direct replacements without checking the existing wiring and load calculations.

Editor’s note

Having 32 channels is useful, but start with the complete label. Match 451-4UA13 through to the final digit; it saves time spent trying to fit an unsuitable spare.

Do not stop at “thirty-two outputs, half an amp each.” Ventilation, module spacing and cabinet temperature affect the combined load. Think about the cabinet when it is warm in the afternoon as well as when it is cool in the morning.

If the program shows an output but the load stays off, give the card a fair check. Start with 1L+/2L+, the F+/F− enable supply and X20 setting. A missing supply can make a healthy module look faulty.

If a fuse opens, inspect the wires and coils connected to that eight-channel group first. This version specifies 6.3 A slow-blow; do not copy a fuse rating from a card with a different suffix.

For a used card, LEDs alone are not enough; test all 32 channels individually with suitable loads. Photograph the label, address setting and front wiring before removal. Those records help when the maintenance job gets busy.

OtomasyonAVM resources and PDF files

+ S5 PDF files and user manuals · About Siemens S5 PLCs. The main reference is the S5-135U/155U System Manual, Section 8.4.10, printed pages 8-50–8-51 / PDF pages 364–365. The document is in English.

Related topics

+ 451-4UA12 · 451-4UA14 · 497-4UA12 crimp connector · 497-4UB12 screw-terminal connector · PLC fault diagnosis.

Browse SIMATIC S5

+ S5 digital output modules · S5 racks · S5 interface modules · Siemens S5 PLC · Siemens second-hand equipment.

Siemens and external references

+ Siemens S5-135U/155U System Manual, C79000-G8576-C199-07 — Section 8.4.10, 8-50–8-51 / PDF 364–365: 451-4UA13 specifications and wiring. Connector table: 8-21 / PDF 335; common temperature conditions: 8-28 / PDF 342. English.

+ Siemens U Periphery — PDF 2: matching functions and technical data for 4UA13/4UA12. U-series system scope and supplementary connection information. English.