6ES5 324-3UA12
Siemens 6ES5 324-3UA12 — S5-115F IM 324 Parallel Interface Module
The Siemens 6ES5 324-3UA12 is an IM 324 parallel interface module linking the two subunits of an S5-115F in the SIMATIC S5 range. Its partner is the IM 304 — 6ES5 304-3UB11. The connection uses a 721 cable over a maximum distance of 10 m.
The module contains two memory areas of 2 K words each for exchanging process data. Siemens ST 50 specifies 1.0 A maximum from the 5 V supply, 5 W maximum power loss and approximately 0.3 kg weight. Within the S5 interface module range, it provides the parallel link between two central controllers.
IM 304 pairing and cable selection
The S5-115F manual states that the IM 324 may only be connected to an IM 304. The IM 304 can be in either subunit A or subunit B. Use the lower interface port on the IM 304 and check switch and jumper settings against Figures 3-19 and 3-20 of the manual.
Select a 721 length suited to the installation from the S5 connecting cable range. Examples include the 721-0BB00, 1 m, 721-0BC50, 2.5 m and 721-0BD20, 3.2 m. Longer cables elsewhere in the range do not increase the 10 m limit for the IM 304–IM 324 parallel link.
Mounting, adapter casing and supply
S5-115F installation uses the 6ES5 491-0LB11 adapter casing. Check the rack and slot arrangement, casing retention and rear board connection together. The 5 V / 1.0 A specification describes consumption from the rack supply; it is not an instruction to apply external 5 V to the front connector.
Inspect cable shielding and the grounding/equipotential bonding arrangement between cabinets. A firmly seated plug alone does not confirm correct shield and chassis connections.
CPU 942F and complete-system checks
Record the installed hardware revision when identifying CPU 942F codes such as 942-7UF12, 942-7UF14 and 942-7UF15. Select the IM 324 against the full CPU number and the existing two-subunit arrangement. Interchangeability between CPU revisions requires separate verification.
Back up the PLC program, COM 115F configuration and subunit information. During troubleshooting, review the cable, IM 304 settings, IM 324 jumpers and system diagnostics together. Complete the S5-115F manual’s commissioning and functional checks after replacement.
IM 324, IM 324R and distributed interfaces
The 6ES5 324-3UR11 is an IM 324R; the 324-3UA12 is an IM 324. Similar names do not establish direct interchangeability. Identify the system’s F/H architecture and complete order number before selecting a replacement.
Keep the application separate when comparing the IM 304-3UA12, IM 314-3UA11 and IM 314R-3UR11. Distributed I/O connections and the IM 304–IM 324 link between two subunits are different arrangements. The 10 m limit on this page applies to the parallel link.
Editor’s note
Take time over the final characters: 3UA12 and 3UR11 identify different models. Photograph the existing card, its IM 304 partner and the CPU labels together. Getting these three details right at the outset helps avoid an unsuitable replacement.
If the two subunits are no longer communicating, check the 721 cable at both ends before setting the card aside. Pay particular attention to the lower port on the IM 304. Cable strain, loose plugs or an earlier wiring change are worth checking first.
Photograph jumper positions before moving anything, then compare them with the manual. Recording an existing setting does not establish that it is correct. Keep the original arrangement available without automatically transferring a possible fault to the replacement.
A used card powering up is a limited test. Where possible, verify data exchange between two subunits with the correct IM 304 and 721 cable. Follow this with the system’s diagnostic and functional checks; one illuminated indicator cannot establish that the complete arrangement works correctly.
An S5-115F may perform safety-related machine functions. Plan the replacement, back up the program and record the checks. Our Siemens S5 overview helps identify the family; use the S5-115F manual below for this module’s configuration and commissioning requirements.
OtomasyonAVM resources and PDFs
+ Siemens S5 PDF files · About Siemens S5 PLCs · S5 interface modules
+ For IM 304/IM 324 connection diagrams, jumper settings and technical specifications, see the S5-115F manual below.
Related topics
+ 304-3UB11 partner module · 491-0LB11 adapter casing · S5 cables · 324-3UR11 IM 324R
Browse SIMATIC S5
+ S5 interface modules · S5 racks · SIMATIC S5 · Siemens second-hand equipment
Siemens and external references
+ Siemens S5-115F Manual — 3-19–3-20: IM 304/IM 324 parallel link and jumper diagrams
+ Same manual — 8-41: 324-3UA12 technical specifications and IM 304 pairing
+ Siemens ST 50, 1998 — 3/94: IM 324, two 2 K-word areas, power and ordering codes
+ Same catalogue — 3/85: 721 cable lengths and ordering codes