6ES5 246-4UA21

The Siemens 6ES5 246-4UA21 is a SIMATIC S5 positioning module for DC drives with incremental encoder feedback. It belongs to the IP 246I family and adjusts the drive speed reference using actual axis position.

+ OtomasyonAVM Siemens S5 manuals and PDF files

Encoder, drive and rack checks

The Siemens IP 246 manual describes closed-loop position control of two independent axes. The family diagram shows encoder inputs X4 and X5 and analog speed reference connector X6. The manual identifies 4UA21 as an earlier incremental version with fewer functions. When checking S5 positioning modules and encoders, match the plug and signal level to the existing S5 cable.

The 4UA31 and 4UA41 are later incremental IP 246I variants. The 4UB11 and 4UB21 are absolute-encoder IP 246A variants. Match the EPROM, COM 246 release and machine data when replacing a card.

Ventilation The German Siemens migration table lists 4UA21 as eigenbelüftet, while its English edition says forced ventilated. The parts catalog supports the German designation. Confirm the installed card revision, rack and airflow before choosing a mounting arrangement.

For a S5-115U installation, record the CPU 943 or CPU 944 label with the rack and slot. Record the CR 700-0LB11 rack and the 491-0LB11 or 491-0LC11 adapter casing separately. Confirm the required layout against the installed cabinet drawings.

If the axis fails to home, trace the reference sensor and limit signals in the existing project. Where those signals use external S5 digital inputs, for example on a 420-4UA11 input card, check the assigned channel. If drive enable is assigned to separate S5 digital outputs, trace the channel on the installed module, such as a 441-4UA14 output card.

The IP 240, IP 241 and IP 266 are separate measurement or positioning modules. In fault records, identify which card reads the position and which card supplies the drive reference.

Editor’s note

Before buying a used card, photograph the 4UA21 and EPROM labels separately. Keep a backup of the working COM 246 project and machine data.

Isolate cabinet power before removing the card. Label the two axis encoder plugs and record the existing jumper and switch positions.

Check encoder direction under safe test conditions. If the actual position moves opposite to the command, compare the encoder signals with the configured direction first.

If the axis cannot find its reference point, check the reference precontact and the encoder zero marker separately. Verify the reference direction and speed in the existing machine data.

For a functional test, observe both actual position and the change in speed reference. Record the existing fault message and hardware revision before swapping cards.

Related topics

+ IP 247 stepper positioning

+ IP 247 stepper motor module

+ IP 267 stepper motor control

Used Siemens equipment

+ SIMATIC S5 special modules

+ Siemens SIMATIC S5

+ Used Siemens equipment

If you have this module to sell, email a label photo, quantity and known condition to otomasyonavm@gmail.com.

External sources

+ Siemens IP 246 manual · Hardware §1, 4UA21 scope note · English

+ Siemens IP 246 manual · German

+ Siemens S5–S7 migration guide · German, p. 48

+ Siemens S5–S7 migration guide · English, p. 48

+ ADEGIS · Exact 6ES5 246-4UA21 parts listing

A dedicated 4UA21 pinout, jumper chart and supported-function table remain unverified. Use the drawing for the installed hardware revision before wiring.