What is Yaskawa 616 G5 VFD?
The Yaskawa 616 G5 variable frequency drive (VFD) is an industrial control device used to adjust the speed of an electric motor by controlling the frequency of the electrical power supplied to the motor. The "G5" designation in the product name indicates that it is the 5th generation of this particular model of VFD. The 616 G5 VFD is designed to be used with three-phase AC motors and it is typically used in industrial settings such as manufacturing plants, water treatment facilities, and other industrial applications.
The Yaskawa GPD 515/G5 is a general purpose AC motor drive that uses sine-coded pulse width modulation to generate an adjustable voltage and frequency three-phase output for complete speed control of most conventional squirrel cage induction motors. The drive has built-in features such as automatic stall prevention and voltage boost to prevent nuisance tripping during load or line side transient conditions. It is designed to not induce any voltage line notching distortion back to the utility line and maintains a displacement power factor of not less than 0.98 throughout its speed range. It is recommended that the person operating, inspecting, or maintaining the drive thoroughly read and understand the manual before proceeding with any operation or maintenance. The manual also includes basic information for the operator control station. This manual applies to both drives labeled GPD 515 or G5.

The Yaskawa GPD 515/G5 variable frequency drive (VFD) has two categories of failure: Alarm and Fault.
An Alarm indication is a warning that a drive trouble condition will soon occur or that a programming error has been made. The drive will continue to operate during an Alarm indication.
A Minor Fault indication is displayed during less serious faults or when a problem exists in the external circuitry. The drive will continue to operate, and a Minor Fault contact will be closed if a multi-function output is programmed for the condition.
A Major Fault indication is displayed when the drive's Fault relay has tripped. This is a serious fault, the motor coasts to a stop, and a fault signal output is present at control circuit terminals 18-20.
It is important to note that in the event of a Major Fault, the drive should be shut down and the cause of the fault should be determined before attempting to restart the drive.
The GPD 515/G5 variable frequency drive (VFD) has two initialization functions, A1-03, that must be used with caution. It's important to know your application before using either Initialization function. This parameter must be set to "0" for Drive mode operation.
"1110" = User Default Parameter Initialization
"2220" = Factory 2-Wire Control Initialization (Maintained RUN Contact)
"3330" = Factory 3-Wire Control Initialization (Momentary START/STOP Contact)
Entering any Initialization code resets all parameters, and automatically returns A1-03 setting to "0". If the GPD 515 is connected for 3-Wire control and this parameter is set to "2220" (2-Wire Control Initialization), the motor may run in reverse direction WITHOUT A RUN COMMAND APPLIED. Equipment damage or personal injury may result, so it is important to be cautious.
Additionally, when the drive is programmed for auto-restart (L5-02 = "1" thru "10"), the motor may restart unexpectedly, leading to potential personal injury. It is important to take necessary precautions and to take the necessary measures to prevent unexpected restarts.
+ Yaskawa Varispeed 616G5 DS597 Pressure sensor kit (pdf)
+ Yaskawa Varispeed 616G5 Logic card (pdf)
+ Yaskawa Varispeed GPD515 115Volt card Manual (pdf)
+ Yaskawa Varispeed GP515 Dynamic braking Manual (pdf)
+ Yaskawa Varispeed DeviceNet Card CM053, CM057, CM055 (pdf)
+ Yaskawa Varispeed Devicenet Comm CM059 module (pdf)
+ Yaskawa Varispeed encoder card PG-W2 dual band (pdf)
+ Yaskawa Varispeed Feedback option card PG-X2 (pdf)
+ Yaskawa Varispeed Profibus dp module CM061 (pdf)
+ Yaskawa Varispeed Analog module DS341, VCD703 GPD503 (pdf)
+ Yaskawa Varispeed PG Card PG-D2, DS13 (pdf)
+ Yaskawa Varispeed RS232c, RS485 Communication CM085 For GPD515 (pdf)
+ Yaskawa Varispeed GPD515 G5 Software download (pdf)
+ Yaskawa Varispeed CDBR brake resistor (pdf)
+ Yaskawa Varispeed 616G5 instruction manual (pdf)
+ Yaskawa Varispeed 616G5 Quick start (pdf)
+ Yaskawa Varispeed 616G5 User Manual (pdf)
+ Yaskawa Varispeed 616G5 Descriptive Manual (pdf)
+ Yaskawa Varispeed 616G5 SysBUS Manual (pdf)