Yaskawa V7 fault codes 2

    FAN (Cooling fan fault):
- Description: Cooling fan is locked.
- Causes and Corrective Actions: Check the cooling fan and its wiring to ensure it is not connected or locked.

    UL3 (Under torque detection):
- Description: Load (output current or output torque) is too low. In V/f mode, the drive output current fell below the preset value in parameter n118. In vector mode, motor current or torque fell below the preset value in parameters n097 and n118.
- Causes and Corrective Actions: Check the driven machine and correct the cause of the fault, or decrease the value of parameter n118.

    Protective operation (when under torque is detected):
- Description: Drive performs operation according to the preset setting of constant n117 when under torque is detected.
- Causes and Corrective Actions: Set parameter n118 to the lowest value allowed for the machine.

    I/O message length from PLC:
- Description: The I/O message length from the PLC does not match the Polled I/O Data length set by parameters n148 and n149.
- Causes and Corrective Actions: Check the PLC data sent and parameters n148 and n149 to ensure they match.

    OC (Overcurrent):
- Description: Drive output current momentarily exceeds approximately 250% of the rated current.
- Causes and Corrective Actions: Check for short circuits at the drive output side, excessive load inertia, extremely rapid acceleration/deceleration times (parameters n019 to n022), use of a special motor, starting the motor during coasting, starting a motor with a capacity greater than the drive rating, and opening/closing of a magnetic contactor at the drive output side.

    OV (Main circuit overvoltage):
- Description: Main circuit DC voltage exceeds the overvoltage detection level because of excessive regenerative energy from the motor.
- Causes and Corrective Actions: Check for insufficient deceleration time (parameters n020 and n022), lowering of minus load (elevator, etc.), increase deceleration time, and connect an optional dynamic braking resistor if needed.

    UV1 (Main circuit low voltage):
- Description: Main circuit DC voltage drops below the low-voltage detection level while the drive output is ON.
- Causes and Corrective Actions: Check for a reduction of input power supply voltage, open phase of input supply, occurrence of momentary power loss, power supply voltage, main circuit power supply wiring connection, and ensure terminal screws are securely tightened.

    UV2 (Control power supply fault):
- Description: Voltage fault of the control power supply is detected.
- Causes and Corrective Actions: Cycle the power. If the fault remains, replace the drive.

    OH (Cooling fin overheat):
- Description: Temperature rise due to drive overload operation or intake air temperature rise.
- Causes and Corrective Actions: Check the load size, V/f pattern setting (parameters n011 to n017), and intake air temperature. Ensure that the intake air temperature does not exceed 122°F (50°C).

    OL1 (Motor overload):
- Description: Motor overload protection operates by built-in electronic thermal overload relay.
- Causes and Corrective Actions: Check the load size or V/f pattern setting (parameters n011 to n017). Set the motor rated current shown on the nameplate in parameter n036.

    OL2 (Drive overload):
- Description: Drive overload protection operates by built-in electronic thermal overload relay.
- Causes and Corrective Actions: Check the load size or V/f pattern setting (parameters n011 to n017). Also, check the drive capacity.

    OL3 (Overtorque detection):
- Description: In V/f mode, the drive output current exceeded the preset value in parameter n098. In Open Loop Vector mode, motor current or torque exceeded the preset value in parameters n097 and n098.
- Causes and Corrective Actions: Check the driven machine and correct the cause of the fault, or increase the value of parameter n098 up to the highest value allowed for the machine. When overtorque is detected, the drive performs operation according to the preset setting of parameter n096.

    EF (External fault):
- Description: Drive receives an external fault input from the control circuit terminal. EF0 to EF7 corresponds to external fault inputs from different control circuit terminals or DEVICENET communications.
- Causes and Corrective Actions: Check the external circuit (sequence) and the corresponding control circuit terminal or DEVICENET communications for any issues.

    CPF-00 (Communication fault with digital operator):
- Description: Drive cannot communicate with the digital operator for 5 seconds or more when power is turned ON.
- Causes and Corrective Actions: Cycle power after checking that the digital operator is securely mounted. If the fault remains, replace the digital operator or drive.

    CPF-01 (Transmission fault with digital operator):
- Description: Transmission fault occurred for 5 seconds or more when transmission starts with the digital operator.
- Causes and Corrective Actions: Similar to CPF-00, cycle power and check the mounting of the digital operator. Replace if necessary.

    CPF-04 (EEPROM fault):
- Description: EEPROM fault of the drive control circuit is detected.
- Causes and Corrective Actions: Record all parameter data and initialize the constants. Cycle power. If the fault remains, replace the drive.

    CPF-05 (A/D converter fault):
- Description: A/D converter fault is detected.
- Causes and Corrective Actions: Cycle power. If the fault remains, replace the drive.

    CPF-06 (Option card connecting fault):
- Description: Option card connecting fault is detected.
- Causes and Corrective Actions: Remove power to the drive and check the connection of the digital operator.

    CPF-07 (Operator control circuit fault):
- Description: Operator control circuit (EEPROM or A/D converter) fault is detected.
- Causes and Corrective Actions: Similar to CPF-00 and CPF-01, cycle power and check the mounting of the digital operator. Replace if necessary.

    OPR (Operator connecting fault):
- Description: Operator connecting fault is detected.
- Causes and Corrective Actions: Cycle power. If the fault remains, replace the drive.

    CE (MODBUS communications fault):
- Description: MODBUS communications fault is detected.
- Causes and Corrective Actions: Check the communication devices or communication signals.

    STP (Emergency stop):
- Description: The drive stops according to parameter n005 after receiving the emergency stop fault signal.
- Causes and Corrective Actions: Check the external circuit (sequence).

    DeviceNet 24V power supply fault:
- Description: DeviceNet 24V power supply is OFF and cannot communicate with the DeviceNet master.
- Causes and Corrective Actions: Check the 24V power supply and cable connections.