EF1 - External Error at S1 Input Terminal
External error at multifunction input terminal S1.
EF2 - External Error at S2 Input Terminal
External error at multifunction input terminal S2.
EF3 - External Error at S3 Input Terminal
External error at multifunction input terminal S3.
EF4 - External Error at S4 Input Terminal
External error at multifunction input terminal S4.
EF5 - External Error at S5 Input Terminal
External error at multifunction input terminal S5.
EF6 - External Error at S6 Input Terminal
External error at multifunction input terminal S6.
EF7 - External Error at S7 Input Terminal
External error at multifunction input terminal S7.
Possible Causes and Solutions:
- An external device triggered an alarm function. Eliminate the cause of the external error and reset the error.
- Wiring is incorrect. Ensure that signal lines are correctly connected to terminals assigned for external error detection. Reconnect the signal line.
- Multifunction contact inputs are set incorrectly. Check that unused terminals are set to 20 to 2F (External Error) in H1-oo. Change terminal settings.
Err - EEPROM Write Error
The written EEPROM data does not match.
Solution:
- Press the button.
- Correct parameter settings.
- Power cycle the drive.
FbH - Over PID Feedback
PID feedback input exceeds the level set in b5-36 for a longer duration than set in b5-37.
Solution:
- Check parameter settings.
- Correct PID feedback wiring.
- Check the feedback sensor for issues or replace if damaged.
FbL - PID Feedback Loss
PID Feedback Loss Detection occurs as an error when programmed, and PID Feedback < PID Feedback Loss Detection Level (b5-13) for PID Feedback Loss Detection Time (b5-14).
Solution:
- Check parameter settings.
- Correct PID feedback wiring.
- Check the sensor on the control side. Replace if damaged.
GF - Ground Fault
The current on the output side of the drive short-circuits to ground more than 50% of the rated current.
Solution:
- Check motor insulation.
- Check motor cable and eliminate short circuit.
- Reduce leakage current at the drive's output.
LF - Output Phase Loss
Phase loss has occurred on the output side of the drive.
Possible Causes and Solutions:
- Output cable connection is disconnected. Check wiring errors and ensure the output cable is properly connected.
- Motor winding is damaged. Check the resistance between motor lines and replace the motor if winding is damaged.
- Output terminal is loose. Tighten terminals with the torque specified in this guide.
- The motor used is less than 5% of the drive's rated current. Check drive and motor capacities.
- An output transistor is damaged. Replace the drive.
- A single-phase motor is used. The drive cannot operate a single-phase motor.
LF2 - Output Current Imbalance
One or more phases of the output current are missing.
Possible Causes and Solutions:
- Phase loss has occurred on the output side of the drive. Check and correct faulty wiring or poor connections on the drive's output side.
- Terminal wires on the output side of the drive are loose. Tighten terminals with the torque specified in this guide.
- No signal from the gate drive card. Replace the drive and contact Yaskawa for assistance.
- Motor impedance or motor phases are unbalanced. Measure the line-to-line resistance for each motor phase and ensure all values are the same.
oC - Over Current
Drive sensors detect an output current greater than the specified overcurrent level.
Possible Causes and Solutions:
- The motor is damaged due to overheating or insulation damage. Check insulation resistance and replace the motor.
- One of the motor cables is short-circuited or there is a grounding issue. Check motor cables and eliminate the short circuit.
- The load is too heavy. Measure the current entering the motor and replace it with a drive of higher capacity if the current value exceeds the drive's rated current.
- Acceleration or deceleration times are too short. Calculate the required torque during the acceleration time according to the load inertia. If the correct amount of torque cannot be set, increase the acceleration time or increase S-curve characteristics.
- The drive is trying to operate a customized motor or a motor larger than the maximum size. Check motor capacity and ensure the drive's rated capacity is greater than or equal to the motor's capacity rating.
oFA00 - Option Card Error (Port A)
The option card is not compatible with the drive.
Possible Cause and Solution:
- The option card is not compatible with the drive. Use a compatible option card.
oFA01 - Option Card Error (Port A)
Replace the option card.
Possible Cause and Solution:
- The option card is not properly connected to the drive. Power off and reconnect the option card.
oFA03 - Option Card Error (Port A)
Option card self-diagnosis error.
Solution:
- Check the option card and replace if necessary.
oFA04 - Option Card Error (Port A)
An error occurred while trying to write to the option card memory.
Solution:
- Check the option card and replace if necessary.
oFA30 - oFA43 - Option Card Error (Port A)
Communication ID error.
Solution:
- Check the option card and replace if necessary. Check and correct communication settings.
-----
"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us." 19.03.2014