Toshiba VF-A5 Fault codes 2

Hi everyone,

Error Codes and Solutions

OL nt: Motor overload
- V/f is incorrect.
- The motor is constrained.
- Continuous running at low speeds.
- The motor is being operated in the overload area.

    Solutions:

- Check the V/f pattern setting.
- Check the load equipment.
- Adjust ULFULF according to the motor's overload handling characteristics at low speeds.

OCr: Dynamic braking resistor overcurrent trip
- The dynamic braking circuit transistor is faulty.

    Solutions:
- Repair is required.

OLr: Dynamic braking resistor overload trip
- The motor decelerated suddenly.
- The DC injection current is too high.

    Solutions:
- Increase the deceleration time dECdEC.
- Decrease the DC injection current dCIdCI and DC injection time dCtdCt.

OH: Overheat
- The cooling fan is not working.
- The fan ventilation inlet is blocked.
- Another heat-generating device is located nearby.
- The thermistor in the unit is dislocated.

    Solutions:
- Check the cooling fan.
- Check the inverter installation space.
- Do not place heat-generating devices near the inverter.
- Check the main circuit PCB CN6.

EFU: DC fuse cut
- The DC fuse is cut.

    Solutions:
- Replacement of the fuse is required.

E: Emergency stop
- The motor was stopped during automatic run or remote operation with the panel.

    Solutions:
- Reset.

EEP 1: EEPROM fault
- An error occurred during writing of data to the EEPROM.

    Solutions:
- Cycle power to the unit OFF/ON. If the error persists, repair is required.

EEP 1: EEPROM fault
- An error occurred during writing of data to the EEPROM.

    Solutions:
- Cycle power to the unit OFF/ON. If the error persists, repair is required.

EEP 2: Initial read fault
- Fault in the internal data.

    Solutions:
- Repair is required.

Err 2: RAM fault
- Fault in the microcontroller RAM.

    Solutions:
- Repair is required.

Err 3: ROM fault
- Fault in the microcontroller ROM.

    Solutions:
- Repair is required.

Err 4: CPU fault
- Fault in the microcontroller CPU.

    Solutions:
- Repair is required.

Err 5: Communication interruption error
- A fault occurred during communication operation.

    Solutions:
- Check the communication device and wiring, etc.

Err 6: Gate array fault
- Fault in the main gate array.

    Solutions:
- Repair is required.

Err 7: Output current detection device fault
- Fault in the output current detection device.

    Solutions:
- Repair is required.

Err 8: Option PCB fault
- Fault in an option PCB.

    Solutions:
- Check the option PCB connections, etc.

Err 9: Optional ROM drop-off error
- Optional ROM is not mounted correctly. (Only for the software version 120)

    Solutions:
- Remount the optional ROM, then enter 3 on F−4F−4 of Pr.FPr.F to clear the data.

*UC: Low current run condition trip

- The output current dropped to the low current detection level while running.

    Solutions:
- Check that it is adjusted to the detection level suitable for the system LCTLCT, ULCULC. If the setting has no abnormality, repair is required.


+ Toshiba VF-A5 User Manual  >>

+ VF-A5 Fault codes 1 >>

+ VF-A5 Fault codes 2 >>

+ VF-A5 Fault codes 3 >>


+ Toshiba 2 Main page -

+ Used VFD Models

+ VFD Main page -

-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  08.03.2013    