6ES7 142-1BD40-0XA0
Siemens main menu › SIMATIC S7 › SIMATIC ET 200
Siemens 6ES7 142-1BD40-0XA0 — ET 200X EM 142, 4 DO 24 V DC/2 A
6ES7 142-1BD40-0XA0 is the ET 200X EM 142, 4 DO DC 24V/2A expansion module in the Siemens ET 200 distributed I/O family. Its four digital outputs control suitable solenoid coils, DC contactors and indicator lights. This model in the ET 200 digital output range has electronic short-circuit protection but no output diagnostics. Protecting an output and reporting its fault to the control system are separate functions.
Order number: 6ES7142-1BD40-0XA0
Series / module: SIMATIC ET 200X / EM 142
Outputs: 4 DO, 24 V DC
Rated channel current: 2 A
Total output current: Maximum 6 A up to 20 °C; maximum 4 A up to 55 °C
Field connection: M12, 5-pole
Protection rating in the product data sheet: IP65
Diagnostic version: Without diagnostics, 0XA0
Role within an ET 200X station
When reviewing the ET 200 system architecture, distinguish the basic module (BM) from an expansion module (EM). This product adds output channels to an ET 200X station; it is not an independent PROFIBUS or PROFINET interface. Assess ET 200 communication options through the basic module. Recording the basic module reference, expansion sequence and existing cable labels together makes replacement work easier.
Five checks before selection or replacement
1. Simultaneous load: Four channels rated at 2 A each do not give the module an 8 A total output capacity. When planning ET 200 power distribution, consider ambient temperature and simultaneously active loads together. Outputs must not be connected in parallel to increase current capacity. Check the load manufacturer's information for starting behaviour as well as the coil's continuous current.
2. M12 pin assignment: When selecting ET 200 connection components, compare more than the connector type. In the manual's Table 7-26, channel 1 is available through X1 or X2, and channel 3 through X3 or X4. Each of these channels must be used at only one socket. Record the output-to-load assignment, particularly where splitter cables are installed.
3. Protection and diagnostics: Short-circuit protection does not imply detailed reporting of a wire break or load fault. If an output fails to operate, inspect the command bit, field cable, load and supply separately. Where actual movement needs confirmation, monitoring a suitable sensor or auxiliary contact through ET 200 digital input modules provides information beyond the output command alone.
4. Load supply and sealing: When checking ET 200 power supply components, assess the 2L+ load supply and return path. Successful station communication does not by itself prove that the loads are correctly supplied. When reviewing the ET 200 special-function and expansion module range and accessories, inspect M12 seals and covers on unused connections; do not assume the protection rating is maintained with an open or damaged connection.
5. Hardware project: Compare the complete order number, module sequence and output addresses in the Siemens S7 hardware project with the installed station. Add a label photograph and cable arrangement to the replacement record. Before selecting a similar-looking module, reassess basic module compatibility and the diagnostic functions required by the application.
Distinguishing 0XA0 from 0XB0
6ES7142-1BD40-0XB0 is the version with diagnostics in the same four-output, 2 A rated channel-current class. 6ES7142-1BD30-0XA0 instead has a 0.5 A channel rating. When comparing products through the Siemens main menu, check both 1BD40 / 1BD30 and 0XA0 / 0XB0; do not treat these references as automatic substitutes.
Editor's note
Keep three details together for maintenance: the complete order number, socket-to-load mapping and simultaneous total current. “A four-output, two-amp module” does not fully identify the correct replacement. Check the required diagnostic capability against the final part of the order number.
Manuals and PDF documentation
Use our Siemens ET 200 PDF and user manuals page to consult the ET 200X Distributed I/O Device manual. EWA 4NEB 780601602-06, 02/2003, section 7.13 covers this model; printed pages 7-54–7-56 contain connection details and technical specifications. Also match the product data sheet to the complete reference 6ES7142-1BD40-0XA0.
Related topics and Siemens navigation
Product family: Siemens main menu | SIMATIC S7 | ET 200 family
Station and field devices: Digital output modules | Additional modules | PROFIBUS and PROFINET
Technical resources: About ET 200 | Power supply modules | ET 200 PDF manuals