6ES5 942-7UA13

Siemens 6ES5 942-7UA13 – SIMATIC S5-115U CPU 942, 10 KB RAM

Siemens 6ES5 942-7UA13 is an A-series CPU 942 central processor module for the SIMATIC S5-115U, with 10 KB internal RAM and a TTY programmer interface. The Siemens A-CPU manual identifies this model in an exact-order-number technical table. When maintaining Siemens S5 and SIMATIC S5 equipment, record the complete 7UA13 suffix, hardware version and operating-system release.

6ES5 942-7UA11 and 6ES5 942-7UA12 are other references in the same CPU class; 6ES5 942-7UB11 belongs to the B series. A proposed replacement involving nearby models such as 6ES5 941-7UA13 requires comparison of memory, program and installed peripherals. Similar front panels alone do not establish replacement suitability.

Internal RAM and Memory Expansion

The 10 KB internal program memory can be expanded to 42 KB total with a suitable RAM or EPROM submodule. The technical table lists limits of 5,120 statements internally and 21,504 statements overall. When selecting an S5 memory submodule, check the separate capacity limits for RAM, EPROM and EEPROM types.

Back up the STEP 5 program and system data before PLC programming or debugging. Record the installed memory-card code, whether its contents are current, and the backup-battery condition. Include the memory arrangement alongside the CPU code when requesting a replacement.

TTY Interface and Communication

The CPU 942’s TTY interface supports connection of a suitable programmer or operator device; a SINEC L1 connection can also be established. Verify electrical compatibility and wiring as well as connector shape when choosing S5 cables and connectors and S5 interface modules.

Check the CPU operating-system release when using existing S5 communication modules and S5 function modules. Siemens IP 252 product information specifies at least Z01 for 6ES5 942-7UA13 when exchanging data using FB 100/FB 101. This requirement concerns the IP 252 data-handling application; it is insufficient to establish approval for every possible CPU application.

Execution Time, Timers and Counters

The exact-model table specifies approximately 1.6 µs per binary operation, 128 timers and 128 counters. The timer range is 0.01–9,990 seconds and the counter range is 0–999. Instruction execution time must be distinguished from the complete program scan time; assess the actual application workload separately.

Supply and Physical Inspection

The table lists 0.8 A from the internal 5 V supply, typical power loss of 4 W and an approximate weight of 1.5 kg. Check the installed S5 rack and chassis and S5 power supply. Keep the rack’s mains input voltage distinct from the CPU’s internal supply ratings.

A change to processors such as 6ES5 943-7UA11 or the dual-interface 6ES5 943-7UB21 requires reassessment of the program and connections. The S5 CPU models section and Siemens S5 PLC overview provide further comparison material. Preserve label photographs, rack positions and the working program backup before replacement.

Editor’s Note

Read the complete 7UA13 suffix before choosing settings or a replacement. Communication applications in particular can depend on the operating-system release.

The internal memory is 10 KB. If a supplier quotes a larger total, ask which memory submodule is included and distinguish a bare CPU from the complete installed arrangement.

Back up the program before removing the battery or memory card. Preserve the working contents first if the battery is weak; replacement hardware cannot restore a missing application program.

If the programmer cannot connect, check the correct TTY cable, connection direction, sockets and programmer in sequence. Comparing against a known-good cable can save considerable fault-finding time.

Where an IP 252 or another specialist module is installed, verify the application blocks, release requirements and actual data exchange. Entering RUN alone does not demonstrate that the machine’s required functions work.

Documentation and PDF Archive

Browse further S5 documents in our S5-115 PDF archive. Consult the manufacturer references below for the UA13 technical table and IP 252 application release requirements.

Related Topics and Nearby Models

6ES5 942-7UA11 · 6ES5 942-7UA12 · 6ES5 942-7UB11 · 6ES5 941-7UA13. These links support model comparison; assess program and system compatibility before selecting a replacement.

Siemens S5 Navigation

Used Siemens products · Siemens S5 main page · S5 CPU models · Memory modules · Cables and connectors · Communication modules

External References

Siemens S5-115U A-CPU Gerätehandbuch – 6ES5 998-0UF12, Edition 03, German: GWA 4NEB 811 6000-01b; printed 15-13 / PDF 465, exact 6ES5 942-7UA13 technical table. TTY interface: 2-2 / PDF 35.

Siemens IP 252 Product Information – S79220-A2485-B-01-7637, English: section 6, page 5; CPU 942-7UA13 Z01 requirement for FB 100/FB 101 data exchange.