6ES5 928-3UB11
Siemens 6ES5 928-3UB11 CPU 928B – S5-135U / S5-155U
Siemens 6ES5 928-3UB11 is a CPU 928B central processor for S5-135U and S5-155U systems in the SIMATIC S5 family. This wide CPU consists of two printed circuit boards. It uses a removable RAM/EPROM submodule for user memory, with a maximum capacity of 64 KB. A further 46 KB of onboard DB RAM is reserved for data blocks.
In existing Siemens S5 PLC installations, it executes the user program, processes machine data and communicates with peripherals. The 64 KB user memory and 46 KB DB RAM serve different purposes. Describing the unit as having “110 KB of onboard program memory” is therefore misleading. The capacity of the fitted memory submodule must be checked separately.
Memory, programming and I/O structure
STEP 5 code and data blocks are stored in suitable RAM or EPROM user memory. When selecting S5 memory modules, check the 376 EPROM / 377 RAM submodules specified for CPU 928B and their complete order numbers. Internal DB RAM cannot hold program code. CPU resources include 256 timers and 256 counters.
Field signals connect through separate digital input modules, digital output modules and analog modules. The timer and counter totals do not describe physical I/O channels. Preparing a replacement CPU also requires checking data blocks, addressing and restart behaviour alongside the program.
SI1 programming connection and optional SI2
SI1 provides a 15-pin PG connection with serial programming communication at 9600 bit/s. Select S5 cables and connectors to suit the electrical interface. SI1 on the CPU front and SI1 accessed through a 923C coordinator are the same interface and cannot be used simultaneously. A correctly configured multiprocessor system can operate with up to four CPUs.
An SI2 slot does not mean that an interface submodule is fitted. Relevant S5 interface modules include 6ES5 752-0AA12 TTY, 6ES5 752-0AA22 V.24/RS232, 6ES5 752-0AA42 RS422/RS485 and 6ES5 752-0AA53 for PG access. Verify the submodule, CPU version and parameters together. RK512, 3964/3964R or open-driver operation depends on the appropriate hardware and software configuration; an RS485 connection alone does not establish Modbus support.
Supply, construction and version differences
The CPU uses 5 V ±5% and 24 V +25%/−17% supply rails. Current consumption is specified as 5 A typical at 5 V and 760 mA maximum at 24 V. Check the complete rack load when assessing the S5 power supply. Units such as 6ES5 955-3LF12 and 6ES5 955-3NF11 must be matched to the rack, input supply and complete order number. CPU dimensions are approximately 40.64 × 233.4 × 160 mm, weight is 1 kg, and protection is IP00.
6ES5 928-3UB12 is a later version with additional functions. Siemens identifies some of these as retrofittable to UB11, including SINEC L1 through SI2; this feature must not be assumed on every UB11. 6ES5 928-3UB21 uses a different, single-width hardware arrangement, while 6ES5 928-3UA21 is a different model from CPU 928B. The “928” number alone is insufficient when choosing a replacement.
Editor's Note
Before buying this CPU, ask whether the memory submodule is included. Do not assume that the program is present just because the CPU has 46 KB of DB RAM. Check the processor, memory and existing program as a complete set.
Back up the program and current data blocks before removing a CPU from a working machine. Check the backup battery too; after memory data loss, an old program file may not restore the machine's latest settings.
For communication faults, first establish whether the connection uses SI1 or SI2. Record the complete 752 submodule code, cable arrangement and parameters. Similar-looking connectors do not necessarily provide the same interface.
STOP, BASP or QVZ does not by itself prove that the CPU is faulty. Read the PG diagnostic information and investigate missing peripherals, addressing and supply problems. An overall reset clears RAM contents, so obtain backups and diagnostic records before considering it.
Finally, inspect the complete two-board assembly, connectors and signs of previous intervention. Do not separate the boards; remove or insert the unit with power switched off. A useful test checks program access, memory and the communication interface in use, as well as the RUN indicator.
Documents and our own resources
See About Siemens S5 PLC for general information and our S5 PDF files section for available document links. For CPU 928B details, use the S5-135U/155U System Manual, C199-07, Section 5.4 together with the CPU 928B Programming Guide, 6ES5 998-2PR21, Section 1.8.
Related topics
CPU 928B 3UB12 · CPU 928B 3UB21 · 923C coordinator · 752 PG interface submodule. These links support comparison and system-component checks; they do not establish direct interchangeability.
Navigation: 6ES5 928-3UB11 main page · Used Siemens models · Siemens S5 PLC · SIMATIC S5.
External references
Siemens S5-135U/155U System Manual – CPU 928B
Siemens CPU 928B Programming Guide – UB11/UB12 function differences